Purpose: Daily online adaptive radiation therapy (oART) opens the opportunity to treat gastric mucosa-associated lymphoid tissue (MALT) lymphoma with a reduced margin. This study reports our early experience of cone beam computed tomography (CBCT)-based daily oART treating gastric MALT lymphoma with breath-hold and reduced margins.
Methods And Materials: Ten patients were treated on a CBCT-based oART system.
Background And Purpose: Daily online adaptive radiotherapy (DART) increases treatment accuracy by crafting daily customized plans that adjust to the patient's daily setup and anatomy. The routine application of DART is limited by its resource-intensive processes. This study proposes a novel DART strategy for head and neck squamous cell carcinoma (HNSCC), automizing the process by propagating physician-edited treatment contours for each fraction.
View Article and Find Full Text PDFPurpose: Optimal head-and-neck cancer (HNC) treatment planning requires accurate and feasible planning goals to meet dosimetric constraints and generate robust online adaptive treatment plans. A new x-ray-based adaptive radiotherapy (ART) treatment planning system (TPS) version 2.0 emulator includes novel methods to drive the planning process including the revised intelligent optimization engine algorithm (IOE2).
View Article and Find Full Text PDFPurpose: Online adaptive radiation therapy (oART) treatment planning requires evaluating the temporal robustness of reference plans and anticipating the potential changes during treatment courses that may even lead to risks unique to the adaptive workflow. This study conducted a risk analysis of the cone beam computed tomography guided adaptive workflow and is the first to assess an adaptive-specific reference planning review that mitigates risk in the planning process to prevent events and treatment deficiencies during adaptation.
Methods And Materials: A quality management team of medical physicists, residents, physicians, and radiation therapists performed a fault tree analysis and failure mode and effects analysis.
Purpose: Online adaptive radiation therapy (oART) has high resource costs especially for head and neck (H&N) cancer, which requires recontouring complex targets and numerous organs-at-risk (OARs). Adaptive radiation therapy systems provide autocontours to help. We aimed to explore the optimal level of editing automatic contours to maintain plan quality in a cone beam computed tomography-based oART system for H&N cancer.
View Article and Find Full Text PDFAdv Radiat Oncol
September 2024
Purpose: Noncoplanar beams and arcs are routinely used to improve dosimetry for intracranial cases, but their application for extracranial cases has been hampered by the risk of collision. This has led to conservative beam selection whose impact on plan dosimetry has not been previously studied.
Methods And Materials: A full-body 3-dimensional patient surface was acquired using optical cameras for a single lung patient at the time of computed tomography simulation.
Purpose: Online adaptive radiotherapy relies on a high degree of automation to enable rapid planning procedures. The Varian Ethos intelligent optimization engine (IOE) was originally designed for conventional treatments so it is crucial to provide clear guidance for lung SAbR plans. This study investigates using the Ethos IOE together with adaptive-specific optimization tuning structures we designed and templated within Ethos to mitigate inter-planner variability in meeting RTOG metrics for both online-adaptive and offline SAbR plans.
View Article and Find Full Text PDFPurpose: Real-time adaptation of thoracic radiation plans is compelling because offline adaptive experiences show that tumor volumes and lung anatomy can change during therapy. We present and analyze a novel adaptive-on-demand (AOD) workflow combining online adaptive radiation therapy (o-ART) on the ETHOS system with image guided radiation therapy delivery on a Halcyon unit for conventional fractionated radiation therapy of locally advanced lung cancer (LALC).
Methods And Materials: We analyzed 26 patients with LALC treated with the AOD workflow, adapting weekly.
Biomed Phys Eng Express
February 2024
This study explored the feasibility of on-couch intensity modulated radiotherapy (IMRT) planning for prostate cancer (PCa) on a cone-beam CT (CBCT)-based online adaptive RT platform without an individualized pre-treatment plan and contours. Ten patients with PCa previously treated with image-guided IMRT (60 Gy/20 fractions) were selected. In contrast to the routine online adaptive RT workflow, a novel approach was employed in which the same preplan that was optimized on one reference patient was adapted to generate individual on-couch/initial plans for the other nine test patients using Ethos emulator.
View Article and Find Full Text PDFBackground: Online adaptive radiotherapy (ART) involves the development of adaptable treatment plans that consider patient anatomical data obtained right prior to treatment administration, facilitated by cone-beam computed tomography guided adaptive radiotherapy (CTgART) and magnetic resonance image-guided adaptive radiotherapy (MRgART). To ensure accuracy of these adaptive plans, it is crucial to conduct calculation-based checks and independent verification of volumetric dose distribution, as measurement-based checks are not practical within online workflows. However, the absence of comprehensive, efficient, and highly integrated commercial software for secondary dose verification can impede the time-sensitive nature of online ART procedures.
View Article and Find Full Text PDFBackground And Purpose: A recently developed biology-guided radiotherapy platform, equipped with positron emission tomography (PET) and computed tomography (CT), provides both anatomical and functional image guidance for radiotherapy. This study aimed to characterize performance of the kilovoltage CT (kVCT) system on this platform using standard quality metrics measured on phantom and patient images, using CT simulator images as reference.
Materials And Methods: Image quality metrics, including spatial resolution/modular transfer function (MTF), slice sensitivity profile (SSP), noise performance and image uniformity, contrast-noise ratio (CNR) and low-contrast resolution, geometric accuracy, and CT number (HU) accuracy, were evaluated on phantom images.
Purposes: To report our experience in a prospective study of implementing a transperineal ultrasound system to monitor intra-fractional prostate motion for prostate stereotactic body radiotherapy (SBRT).
Material And Methods: This IRB-approved prospective study included 23 prostate SBRT patients treated between 04/2016 and 11/2019 at our institution. The prescription doses were 36.
Purpose: Ethos CBCT-based adaptive radiotherapy (ART) system can generate an online adaptive plan by re-optimizing the initial reference plan based on the patient anatomy at the treatment. The optimization process is fully automated without any room for human intervention. Due to the change in anatomy, the ART plan can be significantly different from the initial plan in terms of plan parameters such as the aperture shapes and number of monitor units (MUs).
View Article and Find Full Text PDFPurpose: Deep inspiration breath-hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left-sided breast cancer. We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT).
Materials And Methods: We examined intra- and inter-fraction positional variation of the left lung.
Biomed Phys Eng Express
December 2022
. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy,. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration.
View Article and Find Full Text PDFBackground: Malignancies of the head and neck region, encompassing cutaneous, mucosal, and sarcomatous histologies, are complex entities to manage, comprising of coordination between surgery, radiation therapy, and systemic therapy. Malignancies of the posterior scalp are particular challenging to treat with radiation therapy, given its irregular contours and anatomy as well as the superficial location of the target volume. Bolus material is commonly used in radiation therapy to ensure that the dose to the skin and subcutaneous tissue is appropriate and adequate, accounting for the buildup effect of megavoltage photon treatment.
View Article and Find Full Text PDFBackground And Purpose: Volumetric modulated arc therapy (VMAT) planning for head and neck cancer is a complex process. While the lowest achievable dose for each individual organ-at-risk (OAR) is unknown , artificial intelligence (AI) holds promise as a tool to accurately estimate the expected dose distribution for OARs. We prospectively investigated the benefits of incorporating an AI-based decision support tool (DST) into the clinical workflow to improve OAR sparing.
View Article and Find Full Text PDFPurpose: Radiation therapy dose escalation using stereotactic body radiation therapy may significantly improve both local control (LC) and overall survival (OS) for patients with inoperable pancreas cancer. However, ablative dose cannot be routinely offered because of the risk of causing severe injury to adjacent normal organs. Stereotactic magnetic resonance (MR)-guided adaptive radiation therapy (SMART) represents a novel technique that may achieve safe delivery of ablative dose and improve long-term outcomes.
View Article and Find Full Text PDFTreatment for locally recurrent breast cancer poses a significant challenge because the benefits in local control must be weighed against the increased risk of side effects of the treatment. Frequently, patients have been heavily pre-treated with radiation and several types of chemotherapy. Moreover, they often present with large volumes of bulky disease, further complicating management.
View Article and Find Full Text PDFPurpose: The goal of this study was to investigate x-ray beam profiles at various water depths to characterize the two-dimensional x-ray dose distribution, allowing for off-axis and out-of-field radiation dose estimation for a wide range of x-ray beam spectra commonly encountered in fluoroscopically guided interventional procedures.
Methods: A Siemens Artis interventional fluoroscope was operated in a service mode to generate a continuous x-ray beam at fixed x-ray beam spectra, defined by their kVp and the thickness of additional copper filtration. A PTW scanning water tank with a diode detector was used to measure the x-ray beam profiles at several depths in water at various fields of view and x-ray beam spectra, both parallel and perpendicular to the anode-cathode axis direction.
Radiation therapy remains one of the cornerstones of cancer management. For most cancers, it is the most effective, nonsurgical therapy to debulk tumors. Here, we describe a method to irradiate cancer cells with a linear accelerator.
View Article and Find Full Text PDF