Background: Acetabular labral tears are managed with suture anchors providing good clinical outcomes. Knotless anchors are easier to use and have a quicker insertion time compared to knotted anchors. The purpose of this study was to compare the biomechanical behavior of two different anchor designs (knotted vs.
View Article and Find Full Text PDFWear is a common cause for aseptic loosening in artificial joints. The purpose of this study was to develop an automated diagnostical method for identification of the number and size distribution of wear debris. For this purpose, metal debris samples were extracted from a hip simulator and then analyzed by the electrospray method combined with a differential mobility analyzer, allowing particle detection ranging from several nanometers up to 1 µm.
View Article and Find Full Text PDFPurpose: The proximal chevron osteotomy provides high correctional power. However, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure. This leads to insufficient weight bearing of the first ray and therefore to metatarsalgia.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
June 2013
Purpose: Peroneal tendons are known as active stabilizer in acute ankle sprain while an intact ankle mortise and intact lateral ligaments are required for passive stability of the ankle joint. The goal of this study is to determine the peroneal tendons as passive stabilizer in case of lateral ligament instability.
Methods: Twelve (12) human lower leg cadaver specimens underwent a torsion simulation in the testing system, 858 Mini Bionix(®) (MTS(®) Systems Corporation, Eden Prairie, MN, USA) and a specially designed mounting platform for the specimens.
Introduction: The application of a defect-size metal implant for the treatment of focal articular cartilage lesions of the femoral condyle is of potential concern resulting in cartilage damage to opposing biological structures. This in vitro study aims to determine the tibiofemoral contact pressure with a contoured articular partial femoral resurfacing device under continuous dynamic pressure loads.
Methods: Peak and area contact pressures were determined in eight fresh-frozen cadaveric specimens using a pressure-sensitive sensor placed in the medial compartment above the menisci.
Background: Increased contact stress with a femoral resurfacing prosthesis implanted in the medial femoral condyle and a non-functional meniscus is of concern for potential deleterious effects on tibiofemoral contact mechanics.
Methods: Peak contact pressures were determined in seven fresh frozen human cadaveric specimens using a pressure sensitive sensor placed in the medial compartment above the menisci. A knee simulator was used to test each knee in static stance positions (5 degrees/15 degrees/30 degrees/45 degrees) and through 10 dynamic knee flexion cycles (5-45 degrees) with single body weight ground reaction force which was adjusted to the living body weight of the cadaver donor.
Unlabelled: The effect of hip protectors depends on two factors: (1) mechanical features and (2) wearing time, which depends on the user's compliance. Various biomechanical studies have been performed to test hip protectors' ability in reducing impacts. However, none of these has shown the ability to simulate a fall in a natural way.
View Article and Find Full Text PDFOsteoporotic fractures are caused by both cortical thinning and trabecular bone loss. Both are seen to be important for bone fragility. The relative contributions of cortical versus trabecular bone have not been established.
View Article and Find Full Text PDF