This study presents a combination of High Performance Liquid Chromatography (HPLC) and ultraviolet (UV) detection that provides the quantification of agnuside in human plasma specimens. Reverse-phase chromatographic separation was carried out with C18 column (150 mm × 4.6 mm × 5 μm), at 25°C with isocratic elution of the mobile phase containing methanol: 0.
View Article and Find Full Text PDFThis article has been retracted: please see Elsevier Policy on Article Withdrawal (https://www.elsevier.com/about/policies/article-withdrawal).
View Article and Find Full Text PDFA new high-performance liquid chromatography (HPLC) method was applied for the quantification of the active substance of tofacitinib. Analysis was performed on a Chromasil 100 C18 (100.0 × 4.
View Article and Find Full Text PDFTwo spectrophotometric techniques and a novel HPLC method were consecutively applied for the simultaneous quantification of the active ingredients of emtricitabine (EMC), tenofovir (TNF), and bictegravir (BIC). The first spectrophotometric method is the dual amplitude difference method coupled with the ratio difference method. TNF was determined using the dual amplitude difference method, while BIC and EMC were determined using the ratio difference method.
View Article and Find Full Text PDFThe present study aims to develop an electroanalytical method to determine one of the most significant antineoplastic agents, topotecan (TPT), using a novel and selective molecular imprinted polymer (MIP) method for the first time. The MIP was synthesized using the electropolymerization method using TPT as a template molecule and pyrrole (Pyr) as the functional monomer on a metal-organic framework decorated with chitosan-stabilized gold nanoparticles (Au-CH@MOF-5). The materials' morphological and physical characteristics were characterized using various physical techniques.
View Article and Find Full Text PDFAn HPLC method with UV detection was developed for the determination of carnosic acid in human plasma and applied to a pharmacokinetic study after oral administration of Rosemary extract to a healthy volunteer. Sample preparation depends on liquid-liquid extraction with hexane. Chromatographic separation was achieved with C18 column (150 mm × 4.
View Article and Find Full Text PDFA fast procedure obtained by the combination of fabric phase extraction (FPSE) with high performance liquid chromatography (HPLC) has been developed and validated for the quantification of favipiravir (FVP) in human plasma and breast milk. A sol-gel polycaprolactone-block-polydimethylsiloxane-block-polycaprolactone (sol-gel PCAP-PDMS-PCAP) coated on 100% cellose cotton fabric was selected as the most efficient membrane for FPSE in human plasma and breast milk samples. HPLC-UV analysis were performed using a RP C18 column under isocratic conditions.
View Article and Find Full Text PDFBiogenic amines (BAs) are group of substances that are formed from amino acids by decarboxylation or amination and transamination of aldehydes and ketones. They may have either aliphatic, aromatic or heterocyclic structure. Their quantity determines their effects, optimum amounts are essential for physiological functions, but excess of BAs causes various toxic effects through out human body.
View Article and Find Full Text PDFFor the quantifiable amounts of Telmisartan (TLM) and Hydrochlorothiazide (HYD) in the presence of Amlodipine (AML) in a ternary mixture of synthetic laboratory mixture, a novel, sensitive, quick, and practical reversed-phase high-performance liquid chromatography (RP-HPLC) method was given. In order to separate, a Waters Spherisorb ODS-2 C18 column was used. For HYD, TLM, and AML, these techniques were viable over linearity ranges of 4-12 μg/mL, 4-25 μg/mL, and 5-40 μg/mL, respectively.
View Article and Find Full Text PDFA novel, sensitive, fast, and pratic RP-HPLC methods were presented for the quantitative amounts of Telmisartan (TEL) and Olmesartan (OLM) in the presence of Amlodipin (AML) in a binary mixture of pharmaceutical preparation. Waters Spherisorb ODS-2 C18 column was used for separation. These methods were valid over linearity ranges of 2.
View Article and Find Full Text PDFAn ultrasensitive and selective voltammetric sensor with ultra-trace level detection limit is introduced for idarubicin (IDA) determination in real samples. The as-synthesized nanocomposite was characterized by several techniques, including Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), Raman spectroscopy, Energy-dispersive X-ray spectroscopy (EDX), and Field emission scanning electron microscopy (FE-SEM). The electrocatalytic performance of the developed electrode was observed by cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and chronoamperometry.
View Article and Find Full Text PDFHIAM technique allows the extraction of the original constant signal of each single component out of interference signals of a mixture and further transformed into basic spectrum (D). It includes the methods: ratio subtraction coupled with unified constant subtraction (RS-UCS), constant center (CC) and constant extraction (CE). The technique was introduced for the analysis of two pharmaceutical formulations used to treat cardiovascular diseases.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
February 2021