Publications by authors named "Gizem Berk"

Background: Implant bed preparation with laser is taken into consideration owing to the increased interest in use of lasers in hard tissue surgery. The purpose of this study is to determine the deviations in the position and inclination between the planned and prepared implant beds with Erbium, Chromium doped Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser using stereolithographic (SLA) surgical guides.

Methods: After 3-dimensional (3D) imaging of six sheep lower jaws, computed tomography (CT) images were transformed into 3D models.

View Article and Find Full Text PDF

Objective: The objective of this study was to evaluate the sealing ability of 2 different resin-based endodontic filling systems after smear layer removal with 2 different techniques.

Study Design: Extracted human single-rooted teeth (n = 74) were instrumented using HERO Shaper rotary instruments and irrigated with 1 mL of 2.5% NaOCl between each instrument.

View Article and Find Full Text PDF

Background: This study investigates the effects of erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation and hand instrumentation on the attachment of periodontal ligament (PDL) fibroblasts to periodontally involved root surfaces.

Methods: Twenty-four single-rooted periodontally involved human teeth (test groups), and six healthy premolar teeth extracted for orthodontic reasons (control group) were included in this study. A total of 45 root slices were obtained from all selected teeth and assigned to the following five groups: 1) untreated healthy group (+control); 2) untreated periodontally diseased group (-control); 3) hand instrumentation group (scaled Gracey); 4) laser I, Er,Cr:YSGG laser irradiation setting-I (short pulse); and 5) laser II, Er,Cr:YSGG laser irradiation setting-II (long pulse).

View Article and Find Full Text PDF

The aim of this study was to evaluate the mineral content of dentin prepared using an Er,Cr:YSGG laser at four different power settings, acid etching, and air abrasion. The study teeth comprised 35 molars which were randomly divided into seven equal groups. The occlusal third of the crowns were cut with a slow-speed diamond saw.

View Article and Find Full Text PDF

The aim of this study was to evaluate the mineral content of enamel etched at two different power settings with an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser. Buccal, lingual and mesial or distal surfaces of five premolar teeth were cut, and three enamel slabs were obtained from each tooth. Fifteen enamel specimens were divided into three groups (1 W, 2 W and control) of five specimens each and subjected to Er,Cr:YSGG laser.

View Article and Find Full Text PDF

The purpose of this study was to investigate the efficiency of hand instrumentation and laser irradiation on calculus removal from the root surfaces, in vitro. Thirty-two human teeth, extracted for periodontal reasons, were used in this study. Root surfaces of single-rooted teeth were treated by different methods including (1) conventional hand instruments; (2) hand instruments and tetracycline-hydrochloride (Tet-HCl); (3) erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation, setting I (short pulse); (4) Er,Cr:YSGG laser irradiation, setting II (long pulse).

View Article and Find Full Text PDF

Laser etching has an effect on the mineral content of dentin. The aim of this study was to evaluate the mineral content of dentin prepared at three different power settings with an erbium, chromium:yttrium scandium gallium garnet (Er,Cr:YSGG) laser. The enamel of five, lower, wisdom, molar teeth was removed to expose the dentin surface.