Purpose: The proximity or overlap of planning target volume (PTV) and organs-at-risk (OARs) poses a major challenge in stereotactic body radiation therapy (SBRT) of pancreatic cancer (PACA). This international treatment planning benchmark study investigates whether simultaneous integrated boost (SIB) and simultaneous integrated protection (SIP) concepts in PACA SBRT can lead to improved and harmonized plan quality.
Methods And Materials: A multiparametric specification of desired target doses (gross target volume [GTV], GTV, PTV, and PTV) with 2 prescription doses of GTV = 5 × 9.
Purpose: The Mobius3D system was validated as a modern secondary check dosimetry system. In particular, our objective has been to assess the suitability of the M3D as pre-treatment patient-specific Quality Assurance (QA) tool for Stereotactic Radiosurgery (SRS) HyperArc (HA) treatments. We aimed to determine whether Mobius3D could safely replace the measurements-based patient-specific QA for this type of treatment.
View Article and Find Full Text PDFThis study quantified the incidental dose to the first axillary level (L1) in locoregional treatment plan for breast cancer. Eighteen radiotherapy centres contoured L1-L4 on three different patients (P1,2,3), created the L2-L4 planning target volume (single centre planning target volume, SC-PTV) and elaborated a locoregional treatment plan. The L2-L4 gold standard clinical target volume (CTV) along with the gold standard L1 contour (GS-L1) were created by an expert consensus.
View Article and Find Full Text PDFPurpose: This study aims to compare two methods for the organ dose evaluation in computed tomography (CT) in the head- and thorax regions: an experimental method, using radiochromic films, and a computational one, using a commercial software.
Methods: Gafchromic® XR-QA2 and EBT-3 were characterized in terms of energetic, angular, and irradiation configurations dependence. Two free-in-air irradiation calibration configurations were employed using a CT scanner: with the sensitive surface of the film orthogonal (OC) and parallel (PC) to the beam axis.
Multiple brain metastases single-isocenter stereotactic radiosurgery (SRS) treatment is increasingly employed in radiotherapy department. Before its use in clinical routine, it is recommended to perform end-to-end tests. In this work, we report the results of five HyperArcTM treatment plans obtained by both ionization chamber (IC) and polymer gel.
View Article and Find Full Text PDFRadiotherapy represents a first-line treatment for many inoperable lung tumors. New technologies offer novel opportunities for the treatment of lung cancer with the administration of higher doses of radiation in smaller volumes. Because both therapeutic and toxic treatment effects are dose-dependent, it is important to identify a minimal dose protocol for each individual patient that maintains efficacy while decreasing toxicity.
View Article and Find Full Text PDFThe aim of this work is to verify the potential use of GAFchromic EBT3 and FILMQA pro software for patient specific quality assurance (QA) for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) treatment plans in clinical routine use. In particular, encephalic, pulmonary and lymph node treatments plans were selected for this study. The agreement between the calculated and measured dose distributions were evaluated in terms of ɣ index with 3%3mm, 2%2mm, 1.
View Article and Find Full Text PDFThe peculiar and rare clinical condition below clearly requires a customized care approach in the context of personalized medicine. An 80-year-old female patient who was subjected in 2018 to surgical removal of a cutaneous Merkel cell carcinoma (MCC) nodule located on the posterior surface of the left thigh and to three subsequent palliative radiotherapy treatments developed a fourth relapse in October 2020, with fifteen nodular metastases located in the left thigh and leg. Since the overall macroscopic disease was still exclusively regionally located and microscopic spread was likely extended also to clinically negative skin of the thigh and leg, we performed an irradiation of the whole left lower extremity.
View Article and Find Full Text PDFPurpose: The influence of basic plan parameters such as slice thickness, grid resolution, algorithm type and field size on calculated small field output factors (OFs) was evaluated in a multicentric study.
Methods And Materials: Three computational homogeneous water phantoms with slice thicknesses (ST) 1, 2 and 3 mm were shared among twenty-one centers to calculate OFs for 1x1, 2x2 and 3x3 cm field sizes (FSs) (normalized to 10x10 cm FS), with their own treatment planning system (TPS) and the energy clinically used for stereotactic body radiation therapy delivery. OFs were calculated for each combination of grid resolution (GR) (1, 2 and 3 mm) and ST and finally compared with the OFs measured for the TPS commissioning.
Objectives: To determine interobserver variability in axillary nodal contouring in breast cancer (BC) radiotherapy (RT) by comparing the clinical target volume of participating single centres (SC-CTV) with a gold-standard CTV (GS-CTV).
Methods: The GS-CTV of three patients (P1, P2, P3) with increasing complexity was created in DICOM format from the median contour of axillary CTVs drawn by BC experts, validated using the simultaneous truth and performance-level estimation and peer-reviewed. GS-CTVs were compared with the correspondent SC-CTVs drawn by radiation oncologists, using validated metrics and a total score (TS) integrating all of them.
Background/aim: To evaluate if topical support therapy during static-intensity modulated radiotherapy (sIMRT) course is able to equal the characteristic minimum risk for radiation proctitis of Image-guided volumetric modulated arc therapy (IG-VMAT) treatment among localized prostate cancer patients.
Patients And Methods: Rectal toxicity data of the above patients were retrospectively collected throughout three different clinical periods at our Radiotherapy Deparment: from October 2011 to December 2012, prostate cancer patients were treated with sIMRT and in advance supported by means of daily topical corticosteroids; from January 2013 to November 2016, topical corticosteroids were replaced by daily hyaluronic acid enemas; from December 2016 to May 2018 eligible patients were treated with newly introduced IG-VMAT supported by only on-demand topical corticosteroids.
Results: Among 359 eligible patients, IG-VMAT was proven generally more effective than sIMRT supported by topical medications in terms of proctitis reduction, although without clinical and practical relevance.
Background/aim: This study aimed to analyze the dosimetric gain of the deep-inspiration-breath-hold (DIBH) technique over the free-breathing (FB) one in left breast cancer (LBC) 3D-conformal-radiotherapy (3D-CRT), and simultaneously investigate the anatomical parameters related to heart RT-exposure.
Patients And Methods: Treatment plans were generated in both DIBH and FB scenarios for 116 LBC patients monitored by the Varian RPM™ respiratory gating system for delivery of conventional or moderately hypofractionated schedules (±sequential boost). For comparison, we considered cardiac and ipsilateral lung doses and volumes.
Neo-adjuvant radiotherapy is frequently employed in the therapeutic management of locally advanced rectal cancer (LARC). Radiotherapy can both reduce local recurrence and improve the success of surgical procedures by reducing tumor mass size. However, some patients show a poor response to treatment, which results in primary resistance or relapse after apparent curative surgery.
View Article and Find Full Text PDFPurpose: A large-scale multi-institutional planning comparison on lung cancer SABR is presented with the aim of investigating possible criticism in carrying out retrospective multicentre data analysis from a dosimetric perspective.
Methods: Five CT series were sent to the participants. The dose prescription to PTV was 54Gy in 3 fractions of 18Gy.