Background And Aim: Number of hip prosthesis implants in arthritis, number of patients treated with bisphosphonates to prevent fragility fractures and, together, number of atypical femoral fracture's cases are increasing.
Case Series: This article describes two cases of hip arthritis, treated with hip replacement, in patients using bisphosphonates for a long time; in both cases an incomplete atypical femoral fracture was misdiagnosed before the surgery. Authors describe the importance to carry out a complete osteometabolic and radiographic pre-operative examination of patients in treatment with bisphosphonates going to hip replacement, to check the possible presence of incomplete atypical femoral fracture and to optimize surgical and pharmacological treatment.
The results of treatment of wrist fractures with percutaneous pin fixation in 106 patients are reported. Functional and radiological evaluation was made for all patients. All fractures healed; loss of reduction occurred in only two cases.
View Article and Find Full Text PDF