Background And Aims: Transcatheter aortic valve replacement (TAVR) determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis but data on very long-term durability are lacking. We sought to evaluate the clinical and hemodynamic outcomes of the CoreValve porcine pericardial self-expanding bioprosthesis at 12-year follow-up.
Methods: 882 inoperable or high-risk patients were treated with the CoreValve bioprosthesis in 8 Italian high-volume centers between 2007 and 2011.
Background: There is a growing need for percutaneous coronary intervention (PCI) to be performed within the same transcatheter aortic valve implantation (TAVI) procedure. In such cases, cangrelor, a fast-acting intravenous P2Y12-inhibitor with a short offset, is potential clinical utility to minimize bleeding and vascular complications during large-bore arterial access (LBAA) as well as the thrombotic risk associated with concomitant PCI.
Case Summary: We report two cases of TAVI with an indication to concomitant, high-risk PCI.
Background: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown.
View Article and Find Full Text PDFLimited data are available about the impact of permanent pacemaker (PPM) implantation on long-term survival in patients with a bicuspid aortic valve (BAV) and severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR). We aimed to evaluate the long-term clinical outcomes of patients with BAV with AS who underwent periprocedural PPM implantation after TAVR with a self-expandable prosthesis. Data from patients with BAV and severe AS who underwent TAVR between April 2009 and January 2022 and followed in the framework of the One Hospital ClinicalService-CoreValve Project were collected.
View Article and Find Full Text PDFSymptoms of aortic stenosis (AS) are not proportional to its severity and patients with very severe AS (VSAS) remain asymptomatic for a long time. The appropriate time for intervention in patients with VSAS and the effects of transcatheter aortic valve implantation (TAVI) on left ventricular hypertrophy (LVH) remain debated. Our aim was to compare the procedural and 30-day outcomes of TAVI between patients with VSAS and patients with severe AS (SAS) and the changes in LVH.
View Article and Find Full Text PDFSevere tricuspid regurgitation is associated with the occurrence of right failure and increased morbidity and mortality. Transcatheter heterotopic bi-caval valve implantation might offer symptom relief in these patients that are often at prohibitive surgical risk.
View Article and Find Full Text PDFAims: To investigate the impact of the right ventricle to pulmonary artery (RV-PA) coupling on the outcome of patients undergoing transcatheter aortic valve intervention (TAVI), and to describe changes in right ventricular function, pulmonary hypertension, and their ratio after TAVI.
Methods: Three hundred and seventy-seven patients from the Italian ClinicalService Project, who underwent TAVI between February 2011 and August 2020, were included. Tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio was retrospectively calculated as a surrogate of RV-PA coupling.
Aims: The aim of this study was to minimize the procedure, and reduce the length of hospital stay (LoS) is the future objective for transcatheter aortic valve replacement (TAVI).Aims of the study are to identify procedural and electrocardiographical predictors of fast-track discharge in patients who underwent TAVI.
Methods: Patients treated with TAVI included in the One Hospital ClinicalService project were categorized according to the LoS.
J Invasive Cardiol
February 2022
Objectives: We evaluated the acute and two-year safety and efficacy of using the Corevalve, Evolut R, and Evolut PRO valves for treating failed surgical bioprosthesis from the Italian CoreValve Clinical Service Project.
Background: Valve-in-valve (ViV) TAVR is an emerging treatment option for failed surgical bioprosthesis. Choice of transcatheter valve is an important determinant of procedural and clinical outcomes, however, longer-term data are lacking.
Background: TAVR is a safe alternative to surgical aortic valve replacement (SAVR); however, sex-related differences are still debated. This research aimed to examine gender differences in a real-world transcatheter aortic valve replacement (TAVR) cohort.
Methods: All-comer aortic stenosis (AS) patients undergoing TAVR with a Medtronic valve across 19 Italian sites were prospectively included in the Italian Clinical Service Project (NCT01007474) between 2007 and 2019.
Mechanical intravascular hemolysis is frequently observed following procedures on heart valves and uncommonly observed in native valvular disease. In most cases, its severity is mild. Nevertheless, it can be clinically significant and even life threatening, requiring multiple blood transfusions and renal replacement therapy.
View Article and Find Full Text PDFBackground: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs).
Objectives: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures.
Methods: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI.
Right ventricular primary graft dysfunction after heart transplant is a serious life-threatening condition. The severe form, refractory to maximal medical therapy, has traditionally required temporary mechanical support through veno-arterial extracorporeal membrane oxygenation or central right ventricular support. The Protek Duo is a dual lumen cannula recently introduced in the market, which allows for the institution of a percutaneous right ventricular support.
View Article and Find Full Text PDFObjectives: We aimed to evaluate the effect of transcatheter aortic valve implantation (TAVI) approaches on mortality and identify effect modifiers and predictors for mortality.
Background: Alternative access routes to transfemoral (TF) TAVI include the surgical intra-thoracic direct-aortic (DA) and transapical (TA) approach. TA TAVI has been associated with a higher mortality rate.
Aim: To assess the outcome of nonagenarians patients receiving transcatheter aortic valve replacement (TAVR).
Methods: We aimed to stratify the overall population from an Italian, multicenter, observational project including a total of 3792 consecutive patients who underwent TAVR with CoreValve and Evolut R/PRO devices between April 2009 and October 2018, into four groups according to their age class (≥90 vs. 80-89 years vs.
Circulation
January 2021
Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR.
Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry.
Objective: The aim of this study was to report the 30-day and 1-year outcomes and performance from the Portico Alternative Access study to obtain CE approval of the alternative access delivery system.
Methods: The Portico Alternative Access study is a multicenter, prospective, non-randomized, investigational study (www.clinicaltrials.
Aims: We aim at exploring whether severe chronic kidney disease (CKD) may modify the impact of acute kidney injury (AKI) post-transcatheter aortic valve implantation (TAVI) on early, mid, and long-term mortality.
Methods And Results: The analysis included 2,733 TAVI patients from the Italian Clinical Service Project. The population was stratified in four groups according to the presence of baseline severe CKD and postprocedural AKI.
Aims: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV.
View Article and Find Full Text PDFAims: In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU).
View Article and Find Full Text PDFBackground: Transcatheter aortic valve replacement (TAVR) is the gold standard for severe valvular aortic stenosis in patients at high/prohibitive surgical risk. This procedure has also been used in patients with previous mitral valve (MV) prostheses, with contrasting outcomes reported. The aim of this study is to describe procedural and early outcomes of patients with previous MV prostheses undergoing TAVR.
View Article and Find Full Text PDF