Importance: Cardiac implantable electronic device (CIED) infection is a potentially devastating complication with an estimated 12-month mortality of 15% to 30%. The association of the extent (localized or systemic) and timing of infection with all-cause mortality has not been established.
Objective: To evaluate the association of the extent and timing of CIED infection with all-cause mortality.
Background: The yncope: acing or ecording n hater ears (SPRITELY) trial reported that a strategy of empiric permanent pacing in patients with syncope and bifascicular block reduces major adverse events more effectively than acting on the results of an implantable cardiac monitor (ICM). Our objective was to determine the cost-effectiveness of using the ICM, compared with a pacemaker (PM), in the management of older adults (age > 50 years) with bifascicular block and syncope enrolled in the SPRITELY trial.
Methods: SPRITELY was a pragmatic, open-label randomized controlled trial with a median follow-up of 33 months.
Objectives: In this study, the authors tested whether a strategy of empiric permanent pacing reduces major composite events more effectively than acting on the results of an implantable cardiac monitor (ICM).
Background: Syncope may be caused by intermittent complete heart block in patients with bifascicular heart block, but competing diagnoses coexist. Whether empiric permanent pacing or acting on investigative results provides best care is unknown.
Background: The Prevention of Arrhythmia Device Infection Trial (PADIT) investigated whether intensification of perioperative prophylaxis could prevent cardiac implantable electronic device (CIED) infections. Compared with a single dose of cefazolin, the perioperative administration of cefazolin, vancomycin, bacitracin, and cephalexin did not significantly decrease the risk of infection. Our objective was to compare the microbiology of infections between study arms in PADIT.
View Article and Find Full Text PDFPremature ventricular complexes (PVCs) are increasingly recognized, as the use of ECG wearables becomes more widespread. In particular, PVCs arising from both the right ventricular outflow tract (RVOT) and left ventricular outflow tract (LVOT) comprise the majority of these arrhythmias and form a significant component of an electrophysiology practice. A keen understanding of the correlative anatomy of the outflow tracts, in addition to recognizing key ECG indices illustrating PVC sites of origin, are fundamental in preparing for a successful ablation.
View Article and Find Full Text PDFAims: Post-operative pain following cardiac implantable electronic device (CIED) insertion is associated with patient dissatisfaction, emotional distress, and emergency department visits. We sought to identify factors associated with post-operative pain and develop a prediction score for post-operative pain.
Methods And Results: All patients from the BRUISE CONTROL-1 and 2 trials were included in this analysis.
Background: Cardiac implantable electronic device infection is a major complication that usually requires device removal. PADIT (Prevention of Arrhythmia Device Infection Trial) was a large cluster crossover trial of conventional versus incremental antibiotics.
Objectives: This study sought to investigate independent predictors of device infection in PADIT and develop a novel infection risk score.
Background: Oral anticoagulant use is common among patients undergoing pacemaker or defibrillator surgery. BRUISE CONTROL (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial; NCT00800137) demonstrated that perioperative warfarin continuation reduced clinically significant hematomas (CSH) by 80% compared with heparin bridging (3.5% versus 16%).
View Article and Find Full Text PDFBackground: Infection of implanted medical devices has catastrophic consequences. For cardiac rhythm devices, pre-procedural cefazolin is standard prophylaxis but does not protect against methicillin-resistant gram-positive organisms, which are common pathogens in device infections.
Objective: This study tested the clinical effectiveness of incremental perioperative antibiotics to reduce device infection.
Aims: Guidelines recommend warfarin continuation rather than heparin bridging for pacemaker and defibrillator surgery, after the BRUISE CONTROL trial demonstrated an 80% reduction in device pocket haematoma with this approach. However, direct oral anticoagulants (DOACs) are now used to treat the majority of patients with atrial fibrillation. We sought to understand the best strategy to manage the DOACs at the time of device surgery and specifically hypothesized that performing device surgery without DOAC interruption would result in a reduced haematoma rate.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
December 2018
Purpose: Femoral venous access is required for most electrophysiology procedures. Limited data are available regarding post-procedure venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE). Potential preventative strategies are unclear.
View Article and Find Full Text PDFBackground: Many diagnostic criteria for the differential diagnosis of wide complex tachycardia (WCT) are complex and not completely accurate. Incorrect diagnosis is also related to error in applying criteria.
Objectives: To propose a novel reliable criterion for wide QRS complexes' differential diagnosis.
Background: Implantable cardioverter defibrillator (ICD) leads are subject to technical failures and the impact of the resulting public advisories on patient welfare is unclear. The psychological status of patients who received an advisory for their Medtronic Fidelis ICD lead (Medtronic Inc., Minneapolis, MN, USA) and followed either by self-surveillance for alarm or home monitoring with CareLink was evaluated prospectively and compared to patients with ICDs not under advisory.
View Article and Find Full Text PDFThe first surgical ablation of an accessory pathway for the treatment of Wolff-Parkinson-White (WPW) syndrome was performed in 1968, and surgery remained first-line therapy until the advent of catheter ablation techniques in the early 1990s. Current indications for surgical ablation of WPW syndrome are limited to ablation failures. To this day, there has been no long-term follow-up of these surgically treated patients.
View Article and Find Full Text PDFAims: To quantify the sensitivity of QT heart-rate correction methods for detecting drug-induced QTc changes in thorough QT studies.
Methods: Twenty-four-hour Holter ECGs were analyzed in 66 normal subjects during placebo and moxifloxacin delivery (single oral dose). QT and RR time series were extracted.
Background: Anticoagulation in patients undergoing atrial fibrillation (AF) ablation is crucial to minimize the risk of thromboembolic complications. There are broad ranges of approaches to anticoagulation management pre and post AF ablation procedures. The purpose of this study was to determine the anticoagulation strategies currently in use in patients peri- and post AF ablation in Canada.
View Article and Find Full Text PDFThe QT interval in the electrocardiogram (ECG) is a measure of total duration of depolarization and repolarization. Correction for heart rate is necessary to provide a single intrinsic physiological value that can be compared between subjects and within the same subject under different conditions. Standard formulas for the corrected QT (QTc) do not fully reproduce the complexity of the dependence in the preceding interbeat intervals (RR) and inter-subject variability.
View Article and Find Full Text PDFIndian Pacing Electrophysiol J
December 2010
Introduction: Radiofrequency(RF) ablation has become the first line of therapy for atrial flutter(AFL). Advances in catheter and mapping technologies have led to better understanding and different approaches for treating this arrhythmia. We describe the results of different approaches to ablate this arrhythmia.
View Article and Find Full Text PDFAnalysis of T waves in the ECG is an essential clinical tool for diagnosis, monitoring, and follow-up of patients with heart dysfunction. During atrial flutter, this analysis has been so far limited by the perturbation of flutter waves superimposed over the T wave. This paper presents a method based on missing data interpolation for eliminating flutter waves from the ECG during atrial flutter.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
July 2008