Objectives: Nowadays, a wide variety of software for 3D reconstruction from CT scans is available; they differ for costs, capabilities, a priori knowledge, and, it is not trivial to identify the most suitable one for specific purposes. The article is aimed to provide some more information, having set up various metrics for the evaluation of different software's performance.
Methods: Metrics include software usability, segmentation quality, geometric accuracy, mesh properties and Dice Similarity Coefficient (DSC).
Introduction: Flatfoot is a condition commonly seen in children; however, there is general disagreement over its incidence, characterization and correction. Painful flatfoot accompanied with musculoskeletal and soft tissue problems requires surgery to avoid arthritis in adulthood, the most common surgical approach being two osteotomies to the calcaneus and medial cuneiform bones of the foot.
Objectives: This study focuses on the parametrization of these two bones to understand their bone morphology differences in a population sample among 23 normal subjects.
Polyether-ether-2-ketone (PEKK) is a high-performance thermoplastic polymer used in various fields, from aerospace to medical applications, due to its exceptional mechanical and thermal properties. Nonetheless, the mechanical behavior of 3D-printed PEKK still deserves to be more thoroughly investigated, especially in view of its production by 3D printing, where mechanical properties measured at different scales are likely to be correlated to one another and to all play a major role in determining biomechanical properties, which include mechanical strength on one side and osteointegration ability on the other side. This work explores the mechanical behavior of 3D-printed PEKK through a multiscale approach, having performed both nanoindentation tests and standard tensile and compression tests, where a detailed view of strain distribution was achieved through Digital Image Correlation (DIC) techniques.
View Article and Find Full Text PDFThe study of the spine range of motion under given external load has been the object of many studies in literature, finalised to a better understanding of the spine biomechanics, its physiology, eventual pathologic conditions and possible rehabilitation strategies. However, the huge amount of experimental work performed so far cannot be straightforwardly analysed due to significant differences among loading set-ups. This work performs a meta-analysis of various boundary conditions in literature, focusing on the flexion/extension behaviour of the lumbar spine.
View Article and Find Full Text PDFIndeterminate lung nodules detected on CT scans are common findings in clinical practice. Their correct assessment is critical, as early diagnosis of malignancy is crucial to maximise the treatment outcome. In this work, we evaluated the role of form factors as imaging biomarkers to differentiate benign vs.
View Article and Find Full Text PDFObjective: To validate the use of a polyblend tape suture in equine laryngoplasty (PL).
Study Design: Experimental study.
Animals: Thirty-two cadaveric larynges.
Colour and texture are two perceptual stimuli that determine, to a great extent, the appearance of objects, materials and scenes. The ability to process texture and colour is a fundamental skill in humans as well as in animals; therefore, reproducing such capacity in artificial ('intelligent') systems has attracted considerable research attention since the early 70s. Whereas the main approach to the problem was essentially theory-driven ('hand-crafted') up to not long ago, in recent years the focus has moved towards data-driven solutions (deep learning).
View Article and Find Full Text PDFComputer-assisted analysis of three-dimensional imaging data () has received a lot of research attention as a possible means to improve the management of patients with lung cancer. Building robust predictive models for clinical decision making requires the imaging features to be stable enough to changes in the acquisition and extraction settings. Experimenting on 517 lung lesions from a cohort of 207 patients, we assessed the stability of 88 texture features from the following classes: first-order (13 features), Grey-level Co-Occurrence Matrix (24), Grey-level Difference Matrix (14), Grey-level Run-length Matrix (16), Grey-level Size Zone Matrix (16) and Neighbouring Grey-tone Difference Matrix (five).
View Article and Find Full Text PDFThe ovary is a dynamic mechanoresponsive organ. In vitro, tissue biomechanics was reported to affect follicle activation mainly through the Hippo pathway. Only recently, ovary responsiveness to mechanical signals was exploited for reproductive purposes.
View Article and Find Full Text PDFThe design of loading systems to test biologic samples is often challenging, due to shape variability and non-conventional loading set-ups. In addition to this, large economic investments would not be justified since the loading set up is usually designed for one single or for a limited range of applications. The object of this work is the development of a loading set-up finalised to on-site testing of sutures whose main function is applying a localised tensile load.
View Article and Find Full Text PDFIntramedullary nails constitute a viable alternative to extramedullary fixation devices; their use is growing in recent years, especially with reference to self-locking nails. Different designs are available, and it is not trivial to foresee the respective performances and to provide clinical indications in relation to the type of bone and fracture. In this work a numerical methodology was set up and validated in order to compare the mechanical behavior of two new nailing device concepts with one already used in clinic.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
September 2020
A number of surgical practices are aimed to compensate for tissue relaxation or weakened/atrophied muscles by means of suture prostheses/thread lifts. The success rate of these procedures is often very good in the short term, while it is quite variable among subjects and techniques in the middle-long term. Middle-long term failures are mostly related to suture distraction, loosening or wear, coming from repeated loading cycles.
View Article and Find Full Text PDFA number of applications in the surgical practice are based on tensile sutures aimed to keep soft tissues in place and compensate the exit of neuropathies, prolapses or general tissue relaxation. Long-term behaviour of these constructs need to be carefully examined in order to define tensile forces to be applied and to compare different suture anchors. Data here reported refer to equine laryngoplasties, where a suitable loading system has been designed in order to be able to test sutures in-sito, applying known forces ("On-site testing of sutured organs: an experimental set up to cyclically tighten sutures" (Pascoletti et al.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2019
The pre-operative planning of a hip arthroplasty entails the choice of the prosthetic hip model and of the position of both joint components with reference to bone. Assessing the impact of geometrical factors on the final hip range of motion (ROM) is not trivial, since it requires performing 3D evaluations. Nonetheless, it deserves to be studied since hip impingement and dislocation are still relevant complications in hip arthroplasty.
View Article and Find Full Text PDFThe Marchetti-Vicenzi's nail is an intramedullary device where six curved nails are kept straight by a closing ring in order to allow their insertion into the medullary canal of a long bone; in a following step, these nails stabilize the fracture due to the ring withdrawal and to the consequent elastic expansion of the nails. Pre-clinical testing of this sort of device is strongly advocated in order to be able to foresee their stability inside the medullary canal and to quantify their stiffening action on a broken bone. In this numerical work, an MB (Multi Body) model of the device has been developed, with the dual purpose of evaluating forces between the bone and the system components during its progressive opening and verifying the behavior of the stabilized bone when it undergoes external loading.
View Article and Find Full Text PDFThe optimization of loading protocols following dental implant insertion requires setting up patient-specific protocols, customized according to the actual implant osseointegration, measured through quantitative, objective methods. Various devices for the assessment of implant stability as an indirect measure of implant osseointegration have been developed. They are analyzed here, introducing the respective physical models, outlining major advantages and critical aspects, and reporting their clinical performance.
View Article and Find Full Text PDFObjective: To investigate the influence of implant design on the change in the natural frequency of bone-implant system during osseointegration by means of a modal 3D finite element analysis.
Methods: Six implants were considered. Solid models were obtained by means of reverse engineering techniques.