Background The detection of in-stent restenosis (ISR) with coronary CT angiography (CCTA) is challenging, but CT perfusion (CTP) has demonstrated improved diagnostic accuracy over CCTA in patients with stents. However, there are limited data on the performance of dynamic CTP, which allows noninvasive adjudication of regional myocardial blood flow. Purpose To compare the diagnostic performance of regadenoson-stress dynamic CTP with that of CCTA, using fractional flow reserve (FFR) and the index of microvascular resistance (IMR) as reference standards for epicardial coronary circulation and coronary microcirculation, respectively.
View Article and Find Full Text PDFPatent foramen ovale (PFO) is often diagnosed in patients with cryptogenic stroke, aged > 60-65 years, but few data report the outcomes of PFO closure in elderly patients. Consecutive patients undergoing PFO closure at a single institution between January 2006 and December 2011 were included. Baseline clinical features and cerebral imaging data were collected, and a RoPE score was calculated for each patient.
View Article and Find Full Text PDFTranscatheter closure of a patent foramen ovale (PFO) is performed in cryptogenic stroke and other conditions. Information is lacking for some devices. We aimed to evaluate the Figulla Flex II PFO Occluder (FFP) and Figulla Flex UNI Occluder (FFU) through a retrospective multi-center registry.
View Article and Find Full Text PDFBackground: Percutaneous closure represents the first line of treatment in patients with cryptogenic stroke and documented patent foramen ovale (PFO). Scarce data report the long-term outcomes of patients undergoing PFO closure with the Figulla Flex II device (Occlutech, Germany).
Methods: Consecutive patients undergoing PFO closure with a Figulla Flex II device at a single, high-volume Institution were included.
Background: The ADVANTAGE study demonstrated in a cohort of stented patients a diagnostic accuracy of stress myocardial CT perfusion (CTP) significantly higher than that of coronary CT angiography (CCTA) for the detection of in-stent restenosis (ISR) or CAD progression vs. quantitative coronary angiography (QCA). This is a pre-defined subanalysis of the ADVANTAGE aimed at assessing the difference in terms of diagnostic accuracy vs.
View Article and Find Full Text PDFBackground: Transradial approach for carotid artery stenting (TRCAS) is an established technique in specific anatomies potentially associated with high periprocedural event rate from femoral catheterization. The engagement of left common carotid artery originating from the aortic arch is the most challenging scenario requiring specific catheters and techniques.
Methods: Among 542 consecutive TRCAS 66 had left, non-bovine carotid stenosis as the target vessel.
Periprocedural cerebral microembolization is the most important complication of carotid artery stenting. Among several variables that play a role to reduce this risk, brain protection (proximal vs. distal) plays a pivot role.
View Article and Find Full Text PDFCarotid artery stenting (CAS) is an established technique to treat carotid artery stenosis. Favorable results have been reported in different subsets of patients in both acute and long-term settings. Among the CAS periprocedural variables the type of cerebral protection - distal filter and proximal protection - play a pivot role to reduce cerebral embolization.
View Article and Find Full Text PDFThe association between migraine and patent foramen ovale (PFO) has been documented. We aimed to investigate platelet activation, prothrombotic phenotype, and oxidative stress status of migraineurs with PFO on 100 mg/day aspirin, before and 6 months after PFO closure. Data show that, before PFO closure, expression of the classical platelet activation markers is comparable in patients and aspirin-treated healthy subjects.
View Article and Find Full Text PDFIntroduction: Cardiovascular (CV) disease is the leading mortality cause among women, yet an alarming misrepresentation of women in CV studies and a low awareness of the impact of CV among women still persist to date. The Monzino Women Heart Center has been established as a clinical and research program dedicated to primary prevention of CV disease in women.
Methods: Patients aged between 35 and 60 years and with no history of CV disease underwent a comprehensive evaluation including a cardiologic outpatient visit with electrocardiogram, individual CV risk calculation, first-level cardiovascular examinations and a psychological assessment.
Introduction: In recent years, the new third-generation ultrathin bioresorbable-polymer sirolimus-eluting stent (BP-SES), characterized by some of the thinnest struts among commercially available devices (60-80 μm) and an amorphous silicon carbide coating, has been introduced for the treatment of coronary artery disease (CAD). The present study aimed to assess different clinical outcomes and safety of this drug-eluting stent in male and female patients in a real-world setting.
Methods: The present study is a retrospective analysis including all patients treated with BP-SES between January 2017 and December 2019 at a single high-volume center.
Prosthetic valve (PV) dysfunction (PVD) is a complication of mechanical or biological PV. Etiologic mechanisms associated with PVD include fibrotic pannus ingrowth, thrombosis, structural valve degeneration, and endocarditis resulting in different grades of obstruction and/or regurgitation. PVD can be life threatening and often challenging to diagnose due to the similarities between the clinical presentations of different causes.
View Article and Find Full Text PDFMyocardial infarction with nonobstructive coronary artery disease due to spontaneous coronary artery dissection (SCAD) accounts for 5-8% of acute coronary syndrome (ACS) presentations. The demographic characteristics, risk factors, and management of patients with SCAD differ from those with atherosclerotic disease. The objective of this review is to provide a contemporary understanding of the epidemiology, pathophysiology, clinical presentation, and management of SCAD.
View Article and Find Full Text PDFWe describe the case of a 72-year-old man with severe, asymptomatic in-stent restenosis detected 4 years after index carotid artery stenting (CAS). The patient was deemed at low risk and scheduled for re-angioplasty with a drug-coated balloon as per institution protocol. What at first seemed a simple case suddenly turned into a series of cerebral and vascular complications that were successfully managed with a mix of peripheral, coronary, and imaging techniques.
View Article and Find Full Text PDFThe long-term outcome of mechanical aortic and mitral prosthetic valve (A-PV, M-PV) dysfunction (PVD) remains a serious complication associated with high morbidity and mortality. We sought to evaluate the incremental diagnostic value of combined transthoracic echocardiography (TTE) and fluoroscopy (F) in patients with suspected PVD. A total of 354 patients (178 A-PV, 176 M-PV) were imaged by TTE and F within 5 days of hospital admission.
View Article and Find Full Text PDFBackground: Transcatheter closure of patent foramen ovale (PFO) has been demonstrated to be superior to medical therapy in stroke prevention in selected patients. Beyond traditional permanent metallic devices, NobleStitch EL, a suture-based system, has been developed as a potential alternative.
Case Summary: A 50-year-old man underwent transcatheter closure of PFO with mild interatrial septal bulging and tunnel-like morphology with a NobleStitch device.
Introduction: There is a lack of data on clinical outcomes of percutaneous coronary intervention (PCI) with ultrathin stents on unprotected left main (ULM) coronary artery comparing women and men.
Methods: All patients treated with ULM-PCI with ultrathin stents (struts ≤81 μm) enrolled in the RAIN-CARDIOGROUP VII study were analyzed according to a sex-assessment evaluation. Major adverse cardiovascular event (MACE, a composite of all-cause death, myocardial infarction, target-lesion revascularization [TLR], and stent thrombosis) was the primary endpoint, whereas single components of MACE were the secondary endpoints.
Spontaneous coronary artery dissection (SCAD) has a prevalence between 0.2%-4% of all acute coronary syndromes. Multivessel SCAD is unusual.
View Article and Find Full Text PDFObjectives: The aim of this study was to randomly compare the double-layer Roadsaver stent (RS) (Terumo, Tokyo, Japan) with the single-layer Carotid Wallstent (CW) (Boston Scientific, Santa Clara, California) in association with either distal embolic protection with the FilterWire (FW) device (Boston Scientific) or proximal protection with the Mo.Ma Ultra device (Medtronic, Santa Rosa, California) in patients with lipid-rich carotid plaques.
Background: The role of both stent type and brain protection during carotid artery stenting (CAS) remains unsettled.
Inadvertent perforation of the left internal mammary artery during a blind approach to the subclavian vein for pacemaker or central venous catheter insertion is an emergency that requires immediate treatment. Covered stent deployment is a quick and effective treatment, especially in patients with hemodynamic instability. The procedure may be safely performed by using the radial approach.
View Article and Find Full Text PDFEverolimus-eluting stents are largely used for left main (LM) percutaneous coronary interventions (PCI). Long-term follow-up of patients who underwent LM PCI in a real world clinical setting, in particular women, have been scarcely reported. Consecutive patients who underwent unprotected LM PCI with EES at a single Institution from December 2006 to April 2016 were included.
View Article and Find Full Text PDF