Objective: The purpose of the study was to determine average tensile forces resulting in suture failure while tying a knot during repair of complete radial meniscus tears and to compare the failure tensile force based on meniscus tissue location: the peripheral (red-red) versus inner (white-white).
Design: This study was designed as a cadaveric biomechanical study using 24 menisci harvested from fresh frozen cadaveric knees with midbody radial tears. Tears were repaired using 2-0 nonabsorbable suture in both the inner meniscus and the peripheral meniscus.
Background: Our study addresses the lack of consensus on measuring leg length discrepancy (LLD) after total hip arthroplasty (THA). We will assess the inter-observer variability and correlation between the five most commonly used LLD methods and investigate the use of trigonometric principles in overcoming the limitations of current techniques.
Methods: LLD was measured on postoperative AP pelvic radiographs using five conventional methods.
Background: Surgeons often encounter patients with intestinal failure due to inadequate intestinal length ("short bowel syndrome"/SBS). Treatment in these patients remains challenging and the process of physiologic adaptation may take years to complete, which frequently requires parenteral nutrition. We propose a proof-of-concept mechanical bowel elongation approach using a self-expanding prototype of an intestinal expansion sleeve (IES) for use in SBS to accelerate the adaptation process.
View Article and Find Full Text PDFVaginal agenesis (VA) is frequently associated with mullerian agenesis. VA treatments include mechanical dilation and surgical vaginoplasty. We created a vaginal expansion sleeve (VES) as a novel device to progressively lengthen the vaginal canal.
View Article and Find Full Text PDFBackground: A2 pulley release is often needed for exposure of the lacerated tendon, retrieval of retracted tendons, placement of core sutures, or to permit full motion and gliding of the repaired and edematous tendon. However, there is no agreement in the literature on the specific quantity of pulley venting that can be performed and recommendations are limited to an undefined "judicious release" of the pulleys when necessary.
Methods: Following a previously developed testing protocols, finger kinematics, tendon excursion, and bowstringing were evaluated on cadaveric hands for venting in increments of 20% of the pulley length.
Background: In anterior lumbar interbody fusion (ALIF), the use of integrated screws is attractive to surgeons because of the ease of implantation and no additional profile. However, the number and length of screws necessary for safe and stable implantation in various bone densities is not yet fully understood. The current study aims to determine how important both length and number of screws are for stability of ALIFs.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
May 2024
Background: The Terrible Triad of the elbow is a constellation of elbow dislocation, radial head fracture and coronoid process fracture. A common type of coronoid fracture documented with this triad is type II Regan-Morrey coronoid fractures. The preferred fixation method for this fracture type is the lasso technique, medial-lateral tunnel orientation being the traditional approach.
View Article and Find Full Text PDFFixation of osteochondral fractures after patellar dislocation is typically done using an open approach due to the location of the defect. This is traditionally performed through a medial parapatellar arthrotomy to allow adequate visualization. By using the joystick method, adequate visualization is achieved with a smaller arthrotomy.
View Article and Find Full Text PDFObjective: Newer all-suture, all-inside meniscus repair devices utilize soft suture anchors. The purpose of this study was to compare the biomechanical performance of 4 meniscus repair devices in human cadaver menisci: the JuggerStitch (all-suture, all-inside), the FiberStitch (all-suture, all-inside), a polyether ether ketone (PEEK) all-inside, and an inside-out device.
Design: Forty human cadaver menisci were tested after creating 20 mm longitudinal tears in the posterior meniscus.
Introduction: Current clinical practice suggests using patellar and quadriceps tendon autografts with a 10 mm diameter for ACL reconstruction. This can be problematic for patients with smaller body frames. Our study objective was to determine the minimum diameter required for these grafts.
View Article and Find Full Text PDFObjective: After traumatic knee injuries, chondral fragments can avulse off bone with the progeny fragment becoming a loose body. The loose fragment may be larger than expected when trying to surgically repair the fragment back to its original site. The purpose of this study was to determine whether a loose chondral fragment from the lateral femur condyle would increase in size and weight after soaking in normal saline (NS) for 14 days.
View Article and Find Full Text PDFTotal hip arthroplasty is a widely performed operation allowing disabled patients to improve their quality of life to a degree greater than any other elective procedure. Planning for a THA requires adequate patient assessment and preoperative characterizations of acetabular bone loss via radiographs and specific classification schemes. Some surgeons may be inclined to ream at a larger diameter thinking it would lead to a more stable press-fit, but this could be detrimental to the acetabular wall, leading to intraoperative fracture.
View Article and Find Full Text PDFVaginal atresia is seen in genetic disorders such as Mayer-Rokitansky-Küster-Hauser (MRKH) syndrome, which can cause significant sexual dysfunction. Current treatments include surgical reconstruction or mechanical dilation of the vaginal canal. Mechanical dilation requires patients to be highly motivated and compliant while surgical reconstruction has high rates of complications.
View Article and Find Full Text PDFBackground: Osteochondral autograft transfer (OAT) is a useful technique for full-thickness cartilage lesions of the distal femur. Various techniques recommend harvesting a plug 2 mm longer than the recipient hole to allow for graft impaction. Grafts with limited compressibility may not sit flush when impacted.
View Article and Find Full Text PDFIntroduction: Short-term emergency ventilation is most typically accomplished through bag valve mask (BVM) techniques. BVMs like the AMBU bag are cost-effective and highly portable but are also highly prone to user error, especially in high-stress emergent situations. Inaccurate and inappropriate ventilation has the potential to inflict great injury to patients through hyper- and hypoventilation.
View Article and Find Full Text PDFBackground: Odontoid process fractures are among the most common in elderly cervical spines. Their treatment often requires fixation, which may include use of implants anteriorly or posteriorly. Bone density can significantly affect the outcomes of these procedures.
View Article and Find Full Text PDFStudy Design: Pedicle screw study.
Objective: The selection of pedicle screw parameters usually involves the surgeon's analysis of preoperative CT imaging along with anatomical landmarks and tactile examination. However, there is minimal consensus on a standardized guideline for selection methods on pedicle screws.
J Hand Surg Glob Online
November 2021
Purpose: The purpose of this article is to explore the amount of work, quantitated by flexion and extension cycles, that is needed to obtain a positive Elson test following a central slip injury.
Methods: Thirteen frozen cadaveric fingers from individuals with an average age of 79.6 years were used.
Introduction: Pelvic internal fixation has become a popular method for treatment of unstable pelvic ring injuries. Although successful, one complication is femoral nerve palsy from compression of the connecting rod. In light of this complication, this study was designed to evaluate sagittal inclinations of the rod and the feasibility of using a rod with a constant curvature.
View Article and Find Full Text PDFBackground: The COVID-19 pandemic revealed a substantial and unmet need for low-cost, easily accessible mechanical ventilation strategies for use in medical resource-challenged areas. Internationally, several groups developed non-conventional COVID-19 era emergency ventilator strategies as a stopgap measure when conventional ventilators were unavailable. Here, we compared our FALCON emergency ventilator in a rabbit model and compared its safety and functionality to conventional mechanical ventilation.
View Article and Find Full Text PDFThis article describes a technique for arthroscopic fixation of an osteochondritis dissecans (OCD) lesion of the medial talar dome with headless compression screws. This technique involves creation of a medial transmalleolar portal using a guide and drill. The medial transmalleolar portal grants perpendicular access for screw fixation of OCD lesions in addition to the potential for osteochondral autograft transplantation (OAT).
View Article and Find Full Text PDFPerforming MR investigation on patients instrumented with external fixators is still controversial. The aim of this study is to evaluate the quality of MR imaging of the knee structures in the presence of bridging external fixators. Different cadaveric lower limbs were instrumented with the MR-conditional external fixators Hofmann III (Stryker, Kalamazoo, MI, USA), Large external Fixator (DePuy Synthes, Raynham, MA, USA), XtraFix (Zymmer, Warsaw, IN, USA) and a newer implant of Ketron Peek CA30 and ERGAL 7075 pins, Dolphix, (Citieffe, Bologna, Italy).
View Article and Find Full Text PDFPurpose: To determine the ideal location for anterior cruciate ligament (ACL) suspensory cortical button placement on the lateral femur with the highest failure load and to establish the relationship of tunnel diameter and cortical thickness on load to failure.
Methods: Computed tomography (CT) data were obtained from 45 cadaveric distal femurs. A Cartesian coordinate system was established along the lateral femur with the lateral epicondyle (LE) as a reference point.
Screw stripping during bone fixation is a common occurrence during operations that results in decreased holding capacity and bone healing. We aimed to evaluate the rescue of the stripped screw site using screws of different dimensions. Five screw configurations were tested on cadaveric specimens for pull-out strength (POS).
View Article and Find Full Text PDF