Publications by authors named "Giovanni J Ughi"

Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making.

View Article and Find Full Text PDF
Article Synopsis
  • * Outcomes showed that 80% of aneurysms treated with SEAL Arc achieved complete occlusion, significantly higher than the 21% for WEB, alongside better neointimal coverage (86% vs. 49%).
  • * Histological results indicated that all aneurysms treated with SEAL Arc were completely healed, suggesting the device is a promising option for early aneurysm treatment.
View Article and Find Full Text PDF

Objectives: We sought to investigate whether a novel, fast-pullback, high-frequency optical coherence tomography (HF-OCT) imaging system enables data acquisition with a reduced amount of contrast agents while retaining the same qualitative and quantitative lesion assessment to conventional OCT.

Background: The increased amount of administered contrast agents is a major concern when performing intracoronary OCT.

Methods: The present study is a single-center, prospective, observational study including 10 patients with stable coronary artery disease.

View Article and Find Full Text PDF

Background: High-frequency optical coherence tomography (HF-OCT) is an intravascular imaging method that allows for volumetric imaging of flow diverters in vivo.

Objective: To examine the hypothesis that a threshold for both volume and area of communicating malapposition can be predictive of early aneurysm occlusion.

Methods: Fifty-two rabbits underwent elastase aneurysm formation, followed by treatment with a flow diverter.

View Article and Find Full Text PDF

Background: The micro-architectonics of the subarachnoid space (SAS) remain partially understood and largely ignored, likely the result of the inability to image these structures in vivo. We explored transvascular imaging with high-frequency optical coherence tomography (HF-OCT) to interrogate the SAS.

Methods: In vivo HF-OCT was performed in 10 dogs in both the posterior and anterior cerebral circulations.

View Article and Find Full Text PDF

BACKGROUND New pharmacological approaches are needed to prevent stent restenosis. This study tested the hypothesis that pemafibrate, a novel clinical selective PPARα (peroxisome proliferator-activated receptor α) agonist, suppresses coronary stent-induced arterial inflammation and neointimal hyperplasia. METHODS AND RESULTS Yorkshire pigs randomly received either oral pemafibrate (30 mg/day; n=6) or control vehicle (n=7) for 7 days, followed by coronary arterial implantation of 3.

View Article and Find Full Text PDF

Diagnosis of cerebrovascular disease includes vascular neuroimaging techniques such as computed tomography (CT) angiography, magnetic resonance (MR) angiography (with or without use of contrast agents) and catheter digital subtraction angiography (DSA). These techniques provide mostly information about the vessel lumen. Vessel wall imaging with MR seeks to characterize cerebrovascular pathology, but with resolution that is often insufficient for small lesions.

View Article and Find Full Text PDF

Background: High-frequency optical coherence tomography (HF-OCT) is an intra-vascular imaging technique capable of assessing device-vessel interactions at spatial resolution approaching 10 µm. We tested the hypothesis that adequately deployed Woven EndoBridge (WEB) devices as visualized by HF-OCT lead to higher aneurysm occlusion rates.

Methods: In a leporine model, elastase-induced aneurysms (n=24) were treated with the WEB device.

View Article and Find Full Text PDF

Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries' microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases.

View Article and Find Full Text PDF

Background: Tissue growth over covered branches is a leading cause of delayed thrombotic complications after flow-diverter stenting (FDS). Due to insufficient resolution, no imaging modality is clinically available to monitor this phenomenon.

Objective: To evaluate high-frequency optical coherence tomography (HF-OCT), a novel intravascular imaging modality designed for the cerebrovascular anatomy with a resolution approaching 10 microns, to monitor tissue growth over FDS in an arterial bifurcation model.

View Article and Find Full Text PDF

Purpose: The implantation of flow diverters requires administration of dual anti-platelet therapy, posing the potential for complications. The p48MW HPC (phenox, Bochüm, Germany) hydrophilic-coated flow diverting stent is designed to be anti-thrombotic, thus opening the potential for single anti-platelet therapy. We deploy a novel intravascular high-resolution imaging technique, high-frequency optical coherence tomography (HF-OCT), to study in an animal model the acute thrombus formation on coated p48MW devices versus uncoated control devices.

View Article and Find Full Text PDF

Background: High frequency optical coherence tomography (HF-OCT) is a novel intravascular imaging technology developed for use in the cerebral vasculature. We hypothesize that HF-OCT characterization of intrasaccular device neck coverage can prognosticate exclusion of the aneurysm from the circulation.

Methods: Bifurcation and sidewall aneurysms were made in six dogs.

View Article and Find Full Text PDF

We sought to assess in-stent variations in fractional flow reserve (FFR) in patients with previous percutaneous coronary intervention (PCI) and to associate any drop in FFR with findings by optical coherence tomography (OCT) imaging. Suboptimal post-PCI FFR values were previously associated with poor outcomes. It is not known to which extent in-stent pressure loss contributes to reduced FFR.

View Article and Find Full Text PDF

Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints.

Methods And Results: The main PRISON IV trial randomised 330 patients to either SES or EES.

View Article and Find Full Text PDF

Aims: Qualitative criteria for plaque tissue characterisation by OCT are well established, but quantitative methods lack systematic validation in vivo. High optical attenuation coefficient µt has been associated with unstable plaque features, such as lipid core. The purpose of this study was to validate optical coherence tomography (OCT) attenuation imaging for tissue characterisation in vivo, specifically to detect lipid core in coronary atherosclerotic plaques, and to evaluate quantitatively the ability of OCT attenuation imaging to differentiate thin-cap (TCFA) and thick-cap fibroatheroma (FA).

View Article and Find Full Text PDF

Objectives: To assess the anatomical and functional impact of final kissing balloon inflation (FKBI) after implantation of a dedicated bifurcation stent system.

Background: Current evidence suggests clinical benefit of FKBI in patients undergoing bifurcation dilatation using the Tryton side branch stent (Tryton-SBS). We hypothesized that FKBI improves anatomical reconstruction and functional results of bifurcation treated by Tryton-SBS.

View Article and Find Full Text PDF

Objectives: This study sought to determine whether indocyanine green (ICG)-enhanced near-infrared fluorescence (NIRF) imaging can illuminate high-risk histologic plaque features of human carotid atherosclerosis, and in coronary atheroma of living swine, using intravascular NIRF-optical coherence tomography (OCT) imaging.

Background: New translatable imaging approaches are needed to identify high-risk biological signatures of atheroma. ICG is a U.

View Article and Find Full Text PDF

Optical coherence tomography (OCT) is an optical diagnostic modality that can acquire cross-sectional images of the microscopic structure of the esophagus, including Barrett's esophagus (BE) and associated dysplasia. We developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires high-resolution images of entire gastrointestinal (GI) tract luminal organs. This device has a potential to become a screening method that identifies patients with an abnormal esophagus that should be further referred for upper endoscopy.

View Article and Find Full Text PDF

Objectives: The authors present the clinical imaging of human coronary arteries in vivo using a multimodality optical coherence tomography (OCT) and near-infrared autofluorescence (NIRAF) intravascular imaging system and catheter.

Background: Although intravascular OCT is capable of providing microstructural images of coronary atherosclerotic lesions, it is limited in its capability to ascertain the compositional/molecular features of plaque. A recent study in cadaver coronary plaque showed that endogenous NIRAF is elevated in necrotic core lesions.

View Article and Find Full Text PDF

Aims: Fibrin deposition and absent endothelium characterize unhealed stents that are at heightened risk of stent thrombosis. Optical coherence tomography (OCT) is increasingly used for assessing stent tissue coverage as a measure of healed stents, but cannot precisely identify whether overlying tissue represents physiological neointima. Here we assessed and compared fibrin deposition and persistence on bare metal stent (BMS) and drug-eluting stent (DES) using near-infrared fluorescence (NIRF) molecular imaging in vivo, in combination with simultaneous OCT stent coverage.

View Article and Find Full Text PDF