Publications by authors named "Giorgio Famiglini"

Mass spectrometry (MS) enables precise identification and quantification of molecules, particularly when combined with chromatography. The advent of atmospheric pressure ionization (API) techniques allowed the efficient coupling of liquid chromatography with MS (LC-MS), extending analyses to nonvolatile and thermolabile compounds. API techniques present limitations such as low informative capacity and reproducibility of mass spectra, increasing instrument complexity and costs.

View Article and Find Full Text PDF

Per- and polyfluoroalkyl substances (PFASs) are a class of aliphatic manufactured compounds comprising fluoro-chemicals with varied functional groups and stable carbon-fluorine bonds. They are defined as "forever chemicals" due to their persistent and bioaccumulative character. These substances have been detected in various environmental samples, including water, air, soil, and human blood, posing significant health hazards.

View Article and Find Full Text PDF

Normal-phase liquid chromatography (NPLC) plays a pivotal role in the rapid separation of non-polar compounds, facilitating isomer separation and finding applications in various crucial areas where aprotic solvents are necessary. Similar to reversed-phase liquid chromatography (RPLC), NPLC requires a robust and sensitive detector to unequivocally identify the analytes, such as a mass spectrometer. However, coupling NPLC with mass spectrometry (MS) poses challenges due to the incompatibility between the non-polar solvents used as the mobile phase and the primary ionization techniques employed in MS.

View Article and Find Full Text PDF

One of modern analytical chemistry main challenges is providing as fast as possible results in different application fields. In this view, real-time analysis techniques are experiencing ever-increasing success as they can provide data quickly, almost without sample preparation steps. Most of real-time approaches are based on direct mass spectrometry (DMS), a method of analyzing samples without the need for separation or pre-treatment steps.

View Article and Find Full Text PDF

Solid-phase microextraction (SPME) directly coupled to MS is a widespread technique for determining small molecules in different matrices in many application fields. Here we present a modified microfluidic open interface (MOI) connected to a passive-flow-splitter device (PFS) for the direct coupling of SPME to a liquid-electron ionization (LEI) interface in a tandem mass spectrometer for the analysis of complex biological samples. No chromatographic separation is involved.

View Article and Find Full Text PDF

Negative chemical ionization (NCI) and electron-capture negative ionization (ECNI) are gas chromatography-mass spectrometry (GC-MS) techniques that generate negative ions in the gas phase for compounds containing electronegative atoms or functional groups. In ECNI, gas-phase thermal electrons can be transferred to electrophilic substances to produce M ions and scarce fragmentation. As a result of the electrophilicity requirements, ECNI is characterized by high-specificity and low background noise, generally lower than EI, offering lower detection limits.

View Article and Find Full Text PDF

This review article traces the history of the use of liquid chromatography coupled with mass spectrometry (LC-MS) using electron ionization (EI) from the first attempts up to the present day. At the time of the first efforts to couple LC to MS, 70 eV EI was the most common ionization technique, typically used in gas chromatography-mass spectrometry (GC-MS) and providing highly reproducible mass spectra that could be collated in libraries. Therefore, it was obvious to transport this dominant approach to the early LC-MS coupling attempts.

View Article and Find Full Text PDF

We present a modified microfluidic open interface (MOI) for the direct coupling of Bio-SPME to a liquid electron ionization-tandem mass spectrometry (LEI-MS/MS) system as a sensitive technique that can directly analyze biological samples without the need for sample cleanup or chromatographic separations as well as without measurable matrix effects (ME). We selected fentanyl as test compound. The method uses a C18 Bio-SPME fiber by direct immersion (DI) in urine and plasma and the subsequent quick desorption (1 min) in a flow-isolated volume (2.

View Article and Find Full Text PDF

Herein we present an efficient, column-switching method that relies on a custom-made T-union passive diffusion micromixer to assist water dilution and promote trap solute focusing of a high sample volume dissolved in pure organic solvent using a 0.075 mm i.d.

View Article and Find Full Text PDF

Mass spectrometry has been the "gold standard" for drugs of abuse (DoA) analysis for many decades because of the selectivity and sensitivity it affords. Recent progress in all aspects of mass spectrometry has seen significant developments in the field of DoA analysis. Mass spectrometry is particularly well suited to address the rapidly proliferating number of very high potency, novel psychoactive substances that are causing an alarming number of fatalities worldwide.

View Article and Find Full Text PDF

Current mass spectrometry-based methodologies for synthetic organic reaction monitoring largely use electrospray ionization (ESI), or other related atmospheric pressure ionization-based approaches. Monitoring of complex, heterogeneous systems may be problematic because of sampling hardware limitations, and many relevant analytes (neutrals) exhibit poor ESI performance. An alternative monitoring strategy addressing this significant impasse is condensed phase membrane introduction mass spectrometry using liquid electron ionization (CP-MIMS-LEI).

View Article and Find Full Text PDF

Buprenorphine and its metabolites are routinely monitored to assess patient compliance with drug detoxification programs or as pain killers. A rapid method for the simultaneous analysis of buprenorphine, norbuprenorphine, and glucuronides in urine using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed. Urine samples were diluted in water containing formic acid 0.

View Article and Find Full Text PDF

Liquid Electron Ionization (LEI), is an innovative liquid chromatography-mass spectrometry (LC-MS) interface that converts liquid HPLC eluent to the gas-phase in a mass spectrometer equipped with an electron ionization (EI) source. LEI extends the electronic spectra libraries access to liquid chromatography, providing a powerful tool in the untargeted approacssh. Negligible matrix effects allow accurate quantitative information.

View Article and Find Full Text PDF

Dispersive liquid-liquid microextraction with and without ultrasound assistance (DLLME, UA-DLLME) and microextraction with packed sorbent (MEPS) methods for the extraction and determination of eight different benzodiazepines (BDZ) (chlordiazepoxide, flurazepam, bromazepam, oxazepam, lorazepam, clobazam, clonazepam, and flunitrazepam) in three commercial non-alcoholic and light alcoholic beverages were optimized and compared. Benzodiazepines are frequently used for their extensive diffusion and strong numbing effect in drug-facilitated crimes (DFC). The tiny small amount of sample required for DLLME and MEPS extraction makes them very suitable for specimens collected at the crime scene of DFCs.

View Article and Find Full Text PDF

A novel liquid chromatography-mass spectrometry (LC-MS) interfacing concept is presented and discussed. The new interface, called liquid-EI (LEI), is based on electron ionization (EI) but, differently from any previous attempt, the vaporization of solutes and mobile phase takes place at atmospheric pressure into a specifically designed region, called "vaporization microchannel", before entering the high-vacuum ion source. The interface is completely independent from the rest of the instrumentation and can be adapted to any gas chromatography/mass spectrometry (GC/MS) system, as an add-on for a rapid LC-MS conversion.

View Article and Find Full Text PDF

This article describes a nano-scale method for the determination and quantification of five benzodiazepines (BDZ) in an alcoholic grappa drink (chlordiazepoxide; lorazepam; diazepam; oxazepam; medazepam). BDZ are typically used in drug-facilitated crimes (DFC) for their accessibility and synergistic effects with alcohol. Specimens collected on the crime scene must be rapidly analyzed to prove the crime, though, in most cases, a very small amount is available.

View Article and Find Full Text PDF

This is the first application based on electron ionization (EI) using a Direct-EI LC interface and MS/MS to detect unequivocally target compounds in a very small real sample. The determination and quantification of benzodiazepines in very small residues of beverages, collected at the scene of drug-facilitated crimes are mandatory in legal procedures. A specific and sensitive analytical instrumentation is needed, involving little or no sample preparation.

View Article and Find Full Text PDF

Polycyclic aromatic hydrocarbons (PAHs) are USEPA regulated priority pollutants. Their low aqueous solubility requires very sensitive analytical methods for their detection, typically involving preconcentration steps. Presented is the first demonstrated ‘proof of concept’ use of condensed phase membrane introduction mass spectrometry (CP-MIMS) coupled with direct liquid electron ionization (DEI) for the direct, on-line measurement of PAHs in aqueous samples.

View Article and Find Full Text PDF

Detection of target and non-target substances and their characterization in complex samples is a challenging task. Here we demonstrate that coating the electron ionization (EI) ion source of an LC-MS system with a sol-gel ceramic film can drastically improve the detection of high-molecular weight and high-boiling analytes. A new ion source coated with a ceramic material was developed and tested with a mixture of polycyclic aromatic hydrocarbons (PAH) with an increasing number of rings.

View Article and Find Full Text PDF

Benzodiazepines (BDZs) are widely used as tranquilizers and anti-depressive drugs in common clinical practice. However, their ready availability and their synergistic effects with alcohol make them attractive for criminal intentions. To prove criminal action for legal reasons, it is often necessary to analyze beverage residues from a crime scene.

View Article and Find Full Text PDF

Sudden infant death syndrome (SIDS) and sudden intrauterine unexpected death syndrome (SIUDS) are an unresolved teaser in the social-medical and health setting of modern medicine and are the result of multifactorial interactions. Recently, prenatal exposure to environmental contaminants has been associated with negative pregnancy outcomes, and verification of their presence in fetal and newborn tissues is of crucial importance. A gas chromatography-tandem mass spectrometry (MS/MS) method, using a triple quadrupole analyzer, is proposed to assess the presence of 20 organochlorine pesticides, two organophosphate pesticides, one carbamate (boscalid), and a phenol (bisphenol A) in human brain tissues.

View Article and Find Full Text PDF

Endocrine disrupting compounds (EDCs) include organochlorine pesticides (OCPs), organophosphate pesticides (OPPs), carbamate pesticides, and plasticizers, such as bisphenol A (BPA). They persist in the environment because of their degradation resistance and bioaccumulate in the body tissues of humans and other mammals. Many studies are focused on the possible correlation between in utero exposure to EDCs and adverse health hazards in fetuses and newborns.

View Article and Find Full Text PDF

An LC-MS method for the analysis of personal care and household products without sample preparation is presented. The method takes advantage of the Direct-electron ionization (EI) LC-MS interface for the quantitation of principal components, as well as for the identification of unknown or undeclared ingredients. The technique has proven its inertness toward matrix effects and the electron ionization allows quantitation and library identification.

View Article and Find Full Text PDF

Electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo-ionization (APPI) are the most important techniques for the ionization of liquid samples. However, working under atmospheric pressure conditions, all these techniques involve some chemical rather than purely physical processes, and therefore, side reactions often yield to matrix-dependent ionization efficiencies. Here, a system is presented that combines both soft single-photon ionization (SPI) and hard 70 eV electron impact ionization (EI) of dissolved compounds under vacuum conditions.

View Article and Find Full Text PDF

We investigated the effect of temperature on the packing procedure of nano-LC columns (up to 50 cm) and on their performance. Several slurries of stationary phase were prepared using different solvent mixtures. Their stability was evaluated at several temperatures: 70°C, 50°C, and room temperature.

View Article and Find Full Text PDF