Publications by authors named "Giorgio Fallica"

Mental workload (MW) represents the amount of brain resources required to perform concurrent tasks. The evaluation of MW is of paramount importance for Advanced Driver-Assistance Systems, given its correlation with traffic accidents risk. In the present research, two cognitive tests (Digit Span Test-DST and Ray Auditory Verbal Learning Test-RAVLT) were administered to participants while driving in a simulated environment.

View Article and Find Full Text PDF

The development and validation of a system for multi-site photoplethysmography (PPG) and electrocardiography (ECG) is presented. The system could acquire signals from 8 PPG probes and 10 ECG leads. Each PPG probe was constituted of a light-emitting diode (LED) source at a wavelength of 940 nm and a silicon photomultiplier (SiPM) detector, located in a back-reflection recording configuration.

View Article and Find Full Text PDF

This paper presents a sub-mW ASIC for multimodal brain monitoring. The ASIC is co-integrated with electrode(s) and optodes (i.e.

View Article and Find Full Text PDF

In this work, we investigate some major issues for the use of silicon photomultiplier (SiPM) devices in continuous wave functional near-infrared spectroscopy (CW fNIRS). We analyzed the after-pulsing effect, proposing the physical mechanism causing it, and determining its relevance for CW fNIRS. We studied the SiPM transients occurring as the SiPM device goes from the dark (LED in off state) to the illumination (LED in on state) conditions, and vice-versa.

View Article and Find Full Text PDF

We report development, testing, and characterization of a multichannel optical probe for continuous wave (CW) functional near-infrared spectroscopy (fNIRS) that relies on silicon photomultipliers (SiPMs) detectors. SiPMs are cheap, low voltage, and robust semiconductor light detectors with performances analogous to photomultiplier tubes (PMTs). In contrast with PMTs, SiPMs allow direct contact with the head and transfer of the analog signals through thin cables greatly increasing the system flexibility avoiding optical fibers.

View Article and Find Full Text PDF

We experimentally analyze the signal-to-noise ratio of continuous wave (CW) near infrared spectroscopy (NIRS) reflectance systems based on light emitting diodes and silicon photomultipliers for high performance low cost NIRS biomedical systems. We show that under suitable experimental conditions such systems exhibit a high SNR, which allows an SDS of 7 cm, to our knowledge the largest ever demonstrated in a CW-NIRs system.

View Article and Find Full Text PDF

New equations for paralyzable, non paralyzable and hybrid DT models, valid for any time dependent sources are presented. We show how such new equations include the equations already used for constant rate sources, and how it's is possible to correct DT losses in the case of time dependent sources. Montecarlo simulations were performed to compare the equations behavior with the three DT models.

View Article and Find Full Text PDF