Article Synopsis
  • The study aimed to evaluate the efficacy of shortening the cast immobilization period for distal radius fractures (DRF) from 3-5 weeks to 1 week followed by gradual mobilization.
  • Conducted in various trauma centers, it involved randomly assigning hospitals to either the usual care or the shorter immobilization method, with patients aged 18 to 85 included if they had isolated, non- or minimally displaced DRF.
  • Results showed no significant differences in functional outcomes, pain scores, or patient satisfaction between the two groups, suggesting that the shorter immobilization period may be equally effective as the conventional approach.
View Article and Find Full Text PDF

The conventional treatment for distal radius fractures typically involves immobilization of the injured extremity using a conventional forearm cast. These casts do cause all sorts of discomfort during wear and impose life-style restrictions on the wearer. Personalized 3D printed splints, designed using three-dimensional (3D) imaging systems, might overcome these problems.

View Article and Find Full Text PDF

Purpose: The optimal duration of immobilization for the conservative treatment of non- or minimally displaced and displaced distal radius fractures remains under debate. This research aims to review studies of these treatments to add evidence regarding the optimal immobilization period.

Methods: A comprehensive database search was conducted.

View Article and Find Full Text PDF

The distal radius fracture is a common fracture with a prevalence of 17% on the emergency departments. The conservative treatment of distal radius fractures usually consists of three to six weeks of plaster immobilization. Several studies show that one week of plaster immobilization is safe for non- or minimally displaced distal radius fractures that do not need reduction.

View Article and Find Full Text PDF

Fractures of the superior pubic ramus can be treated with screw insertion into the osseous fixation pathway (OFP) of the anterior column (AC). The entry point determines whether the screw exits the OFP prematurely. This can be harmful when it enters the hip joint or damages soft tissues inside the lesser pelvis.

View Article and Find Full Text PDF

The use of peptides in immunoassays can be favored over the use of the full protein when more cost effective or less toxic approaches are needed, or when access to the full protein is lacking. Due to restricted access to recombinant bovine somatotropin (rbST), a protein enhancing growth and lactating performances of livestock, which use has been banned in the EU, Canada and Australia (amongst others), we developed a peptide-based biorecognition assay on an imaging planar array analyzer. For this, we identified the rbST epitope that is responsible for binding to the rbST-targeting monoclonal antibody 4H12 (MAb 4H12) to be DLEEGILALMR.

View Article and Find Full Text PDF

Thiouracil (2-thiouracil) is a thyreostatic compound that can be used as an illegal growth promoter. In bovine, porcine and other farm animals, low concentrations of thiouracil are detected in urine. There is much debate on which concentrations can be considered to originate from feed ('natural') and which concentrations are caused by the illegal administration of thiouracil for growth-promoting purposes.

View Article and Find Full Text PDF

The elimination of recombinant bovine somatotropin (rbST) and its induced antibodies through milk of 2 formulations is studied to propose a control strategy for its use or abuse. Two dairy cows were treated with alanine-rbST (Ala-rbST), which is identical to endogenous bovine somatotropin, and ten dairy cows were treated with methionine-rbST (Met-rbST), which differs by 1 amino acid from endogenous bovine somatotropin. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method able to measure rbST at a decision limit (CCα) of 0.

View Article and Find Full Text PDF

Nowadays routine residue monitoring involves the analysis of many compounds from different classes, mainly in urine. In the past two decades, developments heavily focused on the use of mass spectrometers (MS) and faster and more sensitive MS detectors have reached the market. However, chromatographic separation (CS) was rather ignored and the cognate developments in CS were not in line.

View Article and Find Full Text PDF

A robust LC-MS/MS method was developed to quantify a large number of phase I and phase II steroids in urine. The decision limit is for most compounds lower than 1ngml with a measurement uncertainty smaller than 30%. The method is fully validated and was applied to assess the influence of administered synthetic steroids and beta-agonists on the steroidogenesis.

View Article and Find Full Text PDF

A non-targeted workflow is reported for the isolation and identification of antimicrobial active compounds using bioassay-directed screening and LC coupled to high-resolution MS. Suspect samples are extracted using a generic protocol and fractionated using two different LC conditions (A and B). The behaviour of the bioactive compound under these different conditions yields information about the physicochemical properties of the compound and introduces variations in co-eluting compounds in the fractions, which is essential for peak picking and identification.

View Article and Find Full Text PDF

According to EU legislation a confirmatory method used for residue analysis should be able to confirm the identity of a compound beyond reasonable doubt. To provide an adequate instrumental set-up, Commission Decision 2002/657/EC introduced the concept of "identification points". A second aspect to assure unequivocal confirmation, is the establishment of ion ratio and retention time criteria.

View Article and Find Full Text PDF

Selective estrogen receptor modulators (SERMs), anti-estrogens and aromatase inhibitors are prohibited in human sports doping. However, they also present a risk of being used illegally in animal husbandry for fattening purposes. A method was developed and validated using UHPLC-MS/MS for the determination and confirmation of SERMs, anti-estrogens and aromatase inhibiters in bovine and porcine urine.

View Article and Find Full Text PDF

The current laboratory network system in support of residue monitoring programmes within the EU formally started in the early 1990s. Since then, it has undergone a gentle evolution incorporating new techniques and methods for quality assurance and, in parallel to the extension of the European Union itself, was further extended. However, a paradigm shift from production-based to risk-based control now is foreseen.

View Article and Find Full Text PDF

Besides the identification point system to assure adequate set-up of instrumentation, European Commission Decision 2002/657/EC includes performance criteria regarding relative ion abundances in mass spectrometry and chromatographic retention time. In confirmatory analysis, the relative abundance of two product ions, acquired in selected reaction monitoring mode, the ion ratio should be within certain ranges for confirmation of the identity of a substance. The acceptable tolerance of the ion ratio varies with the relative abundance of the two product ions and for retention time, CD 2002/657/EC allows a tolerance of 5%.

View Article and Find Full Text PDF

In 2013 the Dutch authorities issued a warning against a dietary supplement that was linked to 11 reported adverse reactions, including heart problems and in one case even a cardiac arrest. In the UK a 20-year-old woman, said to have overdosed on this supplement, died. Since according to the label the product was a herbal mixture, initial LC-MS/MS analysis focused on the detection of plant toxins.

View Article and Find Full Text PDF

Here we present the concept of a protein microarray-based fluorescence immunoassay for multiple biomarker detection in milk extracts by an ordinary smartphone. A multiplex immunoassay was designed on a microarray chip, having built-in positive and negative quality controls. After the immunoassay procedure, the 48 microspots were labelled with Quantum Dots (QD) depending on the protein biomarker levels in the sample.

View Article and Find Full Text PDF

The use of recombinant bovine somatotropin (rbST) to enhance milk production is approved in several countries, but it is prohibited in the European Union. According to EU legislation, it is necessary to confirm positive screening results prior to enforcement. Although adequate screening assays are available nowadays, development of liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory methods to detect low levels of rbST is still a challenge.

View Article and Find Full Text PDF

The endogenous occurrence of natural hormones obstructs the application of classical targeted methods as confirmatory options. In the case of estradiol, the ultimate confirmation of its exogenous administration relies on gas chromatography coupled to combustion/isotope ratio mass spectrometry (GC-C/IRMS). A serum dipeptide composed of pyroglutamic acid and phenylalanine was identified as a potential biomarker of estradiol treatments in adult cows.

View Article and Find Full Text PDF

Current contaminant and residue monitoring throughout the food chain is based on sampling, transport, administration, and analysis in specialized control laboratories. This is a highly inefficient and costly process since typically more than 99% of the samples are found to be compliant. On-site simplified prescreening may provide a scenario in which only samples that are suspect are transported and further processed.

View Article and Find Full Text PDF

Over the past two years low levels of prednisolone have been reported in bovine urine by a number of laboratories in European Union member states. Concentrations vary, but are reported to be below approximately 3 µg l(-1). Forty per cent of bovine urine samples from the Dutch national control plan had concentrations of prednisolone between 0.

View Article and Find Full Text PDF

Sensitive and robust bioassays able to detect nuclear receptor activation are very useful for veterinary and doping control, pharmaceutical industry and environmental scientists. Here, we used bioassays based on human leukemic monocyte lymphoma U937 and human liver hepatocellular carcinoma HepG2 cell lines to detect the ligand-induced activation of the peroxisome proliferator-activated receptor delta (PPARδ). Exposure of U937 cells to the PPARδ agonist GW501516 resulted in a marked increase in mRNA expression of the PPARδ target gene Angptl4 which was quantified by qRT-PCR analysis.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated the metabolism of seven selective androgen receptor modulators (SARMs) using bovine liver enzymes to identify metabolites through advanced liquid chromatography and mass spectrometry techniques.
  • Key metabolic processes included monohydroxylation, nitro-reduction, dephenylation, and demethylation, with the in vivo study on ostarine revealing additional pathways like glucuronidation and sulfation in a male calf's urine.
  • The analytical method developed for detecting SARMs in bovine urine met EU validation standards, demonstrating high sensitivity and reproducibility, making it effective for future regulatory screening.