Publications by authors named "Gilwon Yoon"

Storing bio-specimens in adequate temperatures is an important task in hospitals. Usually an assigned employee records manually the temperatures of the hospital cold storages such as refrigerators and freezers that keep them at regular intervals. In this research, a low power wireless Bluetooth Low Energy network is applied where the central monitoring personal computer, receives the temperature data and stores in a database.

View Article and Find Full Text PDF

Concentration and immersion belong to a similar mental state in which a person is preoccupied with a particular task. In this study, we investigated a possibility of diagnosing two mental states with a subtle difference. Concentration and immersion states were induced to analyze the electroencephalography (EEG) changes during these states.

View Article and Find Full Text PDF

The number of computer game users is increasing as computers and various IT devices in connection with the Internet are commonplace in all ages. In this research, in order to find the relevance of behavioral activity and its associated biosignal, biosignal changes before and after as well as during computer games were measured and analyzed for 31 subjects. For this purpose, a device to measure electrocardiogram, photoplethysmogram and skin temperature was developed such that the effect of motion artifacts could be minimized.

View Article and Find Full Text PDF

We developed a health monitoring system based on the smartphone. A compact and low-power-consuming biosignal monitoring unit (BMU) measured electrocardiogram (ECG), photoplethysmogram (PPG), temperature, oxygen saturation, energy expenditure, and location information. The 2.

View Article and Find Full Text PDF

Impedance spectroscopy was applied to determine glucose concentration in the interstitial fluid for its potential use in diabetic monitoring. For this purpose, the changes in the measured dielectric properties due to the presence of glucose in water and saline solutions were examined between 40 Hz and 110 MHz. Electrode polarization (EP) was a dominant factor which shaped the spectrum at low frequencies.

View Article and Find Full Text PDF

A ubiquitous health monitoring system for multiple users was developed based on a ZigBee and wireless local area network (WLAN) dual-network. A compact biosignal monitoring unit (BMU) for measuring electrocardiogram (ECG), photoplethysmogram (PPG), and temperature was also developed. A single 8-bit microcontroller operated the BMU including most of digital filtering and wireless communication.

View Article and Find Full Text PDF

Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure (BP) was estimated from pulse transit time (PTT) and PPG waveform. PTT is a time interval between an R-wave of electrocardiography (ECG) and a photoplethysmography (PPG) signal.

View Article and Find Full Text PDF

A compact ubiquitous-health monitor operated by single 8-bit microcontroller was made. An integer signal processing algorithm for this microcontroller was developed and digital filtering of ECG (electrocardiogram) and PPG (photoplethysmogram) was performed. Rounding-off errors due to integer operation was solved by increasing the number of effective integer digits during CPU operation; digital filter coefficients and data expressed in decimal points were multiplied by a certain number and converted into integers.

View Article and Find Full Text PDF

We measure the dynamical mechanical properties of human red blood cells. A single cell response is measured with optical tweezers. We investigate both the stress relaxation following a fast deformation and the effect of varying the strain rate.

View Article and Find Full Text PDF

A fiber-based reflectance imaging system was constructed to produce in vivo absorption spectroscopic images of biological tissues with diffuse light in the cw domain. The principal part of this system is the 783-channel fiber probe, composed of 253 illumination fibers and 530 detection fibers distributed in a 20x20 mm square region. During illumination with the 253 illumination fibers, diffuse reflected lights are collected by the 530 detection fibers and recorded simultaneously as an image with an electron multiplying CCD camera for fast data acquisition.

View Article and Find Full Text PDF

We present a method for glucose prediction from mid-IR spectra by independent component analysis (ICA). This method is able to identify pure, or individual, absorption spectra of constituent components from the mixture spectra without a priori knowledge of the mixture. This method was tested with a two-component system consisting of an aqueous solution of both glucose and sucrose, which exhibit distinct but closely overlapped spectra.

View Article and Find Full Text PDF

Quantitative studies on functional state of acupuncture points and meridians have been done mostly by electrical measurement that requires the contact of the electrode on skin and is subject to pressure, humidity, etc. In this study, a new modality of using microwave was investigated. Microwave energy in the frequency range of 250 approximately 550MHz was irradiated on an acupuncture point.

View Article and Find Full Text PDF

Measurement accuracy for predicting glucose in whole blood was studied based on near-infrared spectroscopy. Optimal wavelength regions, preprocessing, and the influence of hemoglobin were examined using partial least-squares regression. Spectra between 1100 and 2400 nm were measured from 98 whole blood samples.

View Article and Find Full Text PDF

Glucose determination based on near-IR spectroscopy is investigated for reflectance and transmittance measurement. A wavelength range is 1100 to 2500 nm, which includes both the combination and overtone bands of glucose absorption. Intralipid solutions are used as samples, where glucose concentrations vary between 0 and 1000 mg/dl.

View Article and Find Full Text PDF

A compact and easy-to-use home health monitor was developed. A palm-size health monitor contained a finger probe as sensor unit. In the finger probe, light from a light emitting diode (LED) array was illuminated on a finger nail bed, and transmitted light was measured to obtain photoplethysmography (PPG) signals.

View Article and Find Full Text PDF

Left-right biophoton asymmetry from the palm and the dorsum of hands from 7 Korean hemiparesis patients were studied. There is a strong tendency that the left-hemiparesis patients emit more biophotons from the right than the left hands, while the right-hemiparesis patient emits more from the left hand. Acupuncture treatment reduces dramatically the left-right asymmetry of biophoton emission rates.

View Article and Find Full Text PDF

The photon counting statistics of biophotons emitted from hands is studied with a view to test its agreement with the Poisson distribution. The moments of observed probability up to seventh order have been evaluated. The moments of biophoton emission from hands are in good agreement while those of dark counts of photomultiplier tube show large deviations from the theoretical values of Poisson distribution.

View Article and Find Full Text PDF

Among the putative mechanisms, by which extremely low frequency (ELF) magnetic field (MF) may affect biological systems is that of increasing free radical life span in organisms. To test this hypothesis, we investigated whether ELF (60 Hz) MF can modulate antioxidant system in mouse brain by detecting chemiluminescence and measuring superoxide dismutase (SOD) activity in homogenates of the organ. Compared to sham exposed control group, lucigenin-initiated chemiluminescence in exposed group was not significantly increased.

View Article and Find Full Text PDF

We have determined the glucose concentration of whole blood from mid-infrared spectra without sample preparation or use of chemical reagents. We selected 1119-1022 cm(-1) as the optimal wavelength range for our measurement by making a first-loading vector analysis based on partial least-squares regression. We examined the influence of hemoglobin on samples by using different calibration and prediction sets.

View Article and Find Full Text PDF

A method and device for measuring glucose concentration in a scattering medium have been developed. A spectral range of 800-1800 nm is considered for wavelength selection because of its deeper penetration into biological tissue and the presence of a glucose absorption band. An algorithm based on selected wavelengths is proposed to minimize interference from other components.

View Article and Find Full Text PDF

Wavelength selection and prediction algorithm for determining total hemoglobin concentration are investigated. A model based on the difference in optical density induced by the pulsation of the heart beat is developed by taking an approximation of Twersky's theory on the assumption that the variation of blood vessel size is small during arterial pulsing. A device is constructed with a five-wavelength light emitting diode array as the light source.

View Article and Find Full Text PDF