March 2023
The implementation of MRI-guided online adaptive radiotherapy has enabled extension of therapeutic radiographers' roles to include contouring. An offline interobserver variability study compared five radiographers' and five clinicians' contours on 10 MRIs acquired on a MR-Linac from 10 patients. All contours were compared to a "gold standard" created from an average of clinicians' contours.
View Article and Find Full Text PDFBackground And Purpose: The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers' roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed.
Materials And Methods: 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession.
Background: The prostate demonstrates inter- and intra- fractional changes and thus adaptive radiotherapy would be required to ensure optimal coverage. Daily adaptive radiotherapy for MRI-guided radiotherapy can be both time and resource intensive when structure delineation is completed manually. Contours can be auto-generated on the MR-Linac via a deformable image registration (DIR) based mapping process from the reference image.
View Article and Find Full Text PDFTech Innov Patient Support Radiat Oncol
March 2022
The implementation of adaptive radiotherapy for prostate cancer compensates for inter-fraction motion, at the penalty of increased time in room. The subsequent increase in bladder filling may impact dosimetry, which we have investigated on ten patients treated on the MR-linac. Patients drank water before treatment, to achieve a bladder volume of 200-300 cm.
View Article and Find Full Text PDFTech Innov Patient Support Radiat Oncol
June 2021
More than 60,000 plastic cups were used annually for bladder preparation in one radiotherapy centre. As an alternative, patients were provided with a specifically designed reusable water bottle, aiming to reduce waste and improve bladder filling compliance. Cup usage and bladder volume at treatment were calculated pre- and post-implementation.
View Article and Find Full Text PDFTech Innov Patient Support Radiat Oncol
March 2020
The MR-Linac (MRL) provides a novel treatment modality that enables online adaptive treatments, but also creates new challenges for patient positioning in a laser-free environment. The accuracy and duration of prostate patient set-up on the MRL using two different methods for patient alignment was determined to establish standard of practice on the MRL. Differences in set-up accuracy were significant in the longitudinal direction and are accounted for in online plan adaption.
View Article and Find Full Text PDF