Publications by authors named "Gillian A J Jessurun"

Objectives: The optimal targeted temperature in patients with shockable rhythm is unclear, and current guidelines recommend targeted temperature management with a correspondingly wide range between 32°C and 36°C. Our aim was to study survival and neurologic outcome associated with targeted temperature management strategy in postarrest patients with initial shockable rhythm.

Design: Observational substudy of the Coronary Angiography after Cardiac Arrest without ST-segment Elevation trial.

View Article and Find Full Text PDF
Article Synopsis
  • A study was conducted on 552 patients who were resuscitated after cardiac arrest without STEMI, comparing immediate versus delayed coronary angiography and its impact on heart function.
  • Results showed no significant improvement in left ventricular function, with ejection fractions of 45.2% and 48.4% for immediate and delayed groups, respectively.
  • The conclusion indicates that immediate coronary angiography does not enhance heart dimensions or function compared to delaying the procedure after neurological recovery.
View Article and Find Full Text PDF

Objectives: To compare 2-year outcome following treatment with drug-eluting stents (DES) for acute myocardial infarction (MI) versus non-MI clinical syndromes. In acute MI patients, a stent-level comparison was performed, comparing Resolute Onyx versus Orsiro stents.

Background: In patients presenting with acute MI, higher adverse event rates have been reported.

View Article and Find Full Text PDF

Sex differences in out-of-hospital cardiac arrest (OHCA) patients are increasingly recognized. Although it has been found that post-resuscitated women are less likely to have significant coronary artery disease (CAD) than men, data on follow-up in these patients are limited. Data for this data in brief article was obtained as a part of the randomized controlled Coronary Angiography after Cardiac Arrest without ST-segment elevation (COACT) trial.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates whether sex influences survival rates in patients who experience out-of-hospital cardiac arrest (OHCA) without ST-segment elevation myocardial infarction (STEMI).
  • Overall one-year survival rates were similar for men (63.4%) and women (59.6%), with no significant sex differences found.
  • Women had a lower occurrence of significant coronary artery disease (CAD), but when CAD was present, their survival was worse compared to women without CAD, while men did not show this discrepancy; immediate coronary angiography did not improve survival for either sex.
View Article and Find Full Text PDF

Background: Patients with diabetes have more extensive coronary disease, resulting in higher risks of adverse clinical events following stenting. In all-comer patients, contemporary DES have shown excellent safety and efficacy, but data on diabetic patients are scarce. Separately for the BIO-RESORT and BIONYX trials, we assessed the 2-year clinical outcomes of diabetic patients, treated with various contemporary drug-eluting stents (DES).

View Article and Find Full Text PDF

Background: Patients aged ≥80 years are often treated with new-generation drug-eluting stents (DES), but data from randomized studies are scarce owing to underrepresentation in most trials. We assessed 1-year clinical outcome of octogenarians treated with new-generation DES versus younger patients.

Methods: We pooled patient-level data of 9,204 participants in the TWENTE, DUTCH PEERS, BIO-RESORT, and BIONYX (TWENTE I-IV) randomized trials.

View Article and Find Full Text PDF

Importance: Ischemic heart disease is a common cause of cardiac arrest. However, randomized data on long-term clinical outcomes of immediate coronary angiography and percutaneous coronary intervention (PCI) in patients successfully resuscitated from cardiac arrest in the absence of ST segment elevation myocardial infarction (STEMI) are lacking.

Objective: To determine whether immediate coronary angiography improves clinical outcomes at 1 year in patients after cardiac arrest without signs of STEMI, compared with a delayed coronary angiography strategy.

View Article and Find Full Text PDF

Background: Numerous randomized clinical trials have demonstrated the superiority of thin-strut biodegradable polymer second-generation drug-eluting stent to the first-generation drug-eluting stent and the noninferiority to the thin-strut second-generation permanent polymer drug-eluting stent. Data on long-term clinical outcomes with a novel ultrathin drug-eluting stent, to date, are limited.

Methods: The DESSOLVE III trial (Multicenter Randomized Study of the MiStent Sirolimus Eluting Absorbable Polymer Stent System for Revascularization of Coronary Arteries; n=1398) is a prospective, multicenter, single-blinded, all-comers, randomized controlled trial (NCT02385279), allocating in a 1:1 ratio to either ultrathin-strut biodegradable polymer MiStent sirolimus-eluting stent or to thin-strut permanent polymer Xience everolimus-eluting stent.

View Article and Find Full Text PDF

Objectives: The aim of this study was to assess 2-year safety and efficacy of the current-generation thin composite-wire-strut durable-polymer Resolute Onyx zotarolimus-eluting stent (ZES), compared with the ultrathin-strut biodegradable-polymer Orsiro sirolimus-eluting stent (SES) in all-comers and a pre-specified small-vessel subgroup analysis.

Background: The Resolute Onyx ZES is widely used in clinical practice, but no follow-up data beyond 1 year have been published. The randomized BIONYX (Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents) trial (NCT02508714) established the noninferiority of ZES versus SES regarding target vessel failure (TVF) rates.

View Article and Find Full Text PDF

Objectives: This study sought to assess 2-year clinical outcome following percutaneous coronary intervention (PCI) with thin-strut new-generation drug-eluting stents (DES) in patients treated in proximal left anterior descending artery (P-LAD) versus non-P-LAD lesions.

Background: In current revascularization guidelines, P-LAD coronary artery stenosis is discussed separately, mainly because of a higher adverse event risk and benefits of bypass surgery.

Methods: The study included 6,037 patients without previous bypass surgery or left main stem involvement from the TWENTE I, II, and III randomized trials.

View Article and Find Full Text PDF

Objectives: To assess long-term safety and efficacy of the Xposition S self-apposing stent in the treatment of unprotected left main coronary artery (ULMCA) disease.

Background: Percutaneous intervention with stents has emerged as a valid alternative to surgical revascularization to treat ULMCA disease. Conventional balloon-expandable stents face technical challenges, particularly in large left main diameter requiring extensive optimization and side branch access in distal bifurcation.

View Article and Find Full Text PDF
Article Synopsis
  • * In a multicenter trial, 552 patients without STEMI were randomly assigned to receive immediate or delayed coronary angiography, with survival rates at 90 days as the primary focus.
  • * Results showed no significant difference in survival rates between the immediate angiography (64.5% alive) and delayed angiography (67.2% alive) groups after 90 days, suggesting that immediate intervention may not offer a survival advantage in these cases.
View Article and Find Full Text PDF

Background: During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts.

View Article and Find Full Text PDF

Aim: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent.

Methods And Results: The BIONYX trial (ClinicalTrials.gov-no.

View Article and Find Full Text PDF

Objectives: The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts).

Background: The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices.

View Article and Find Full Text PDF

Background: MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical effect of MiStent sirolimus-eluting stent compared with a durable polymer drug-eluting stents has not been investigated in a large randomised trial in an all-comer population.

View Article and Find Full Text PDF

Objective: Limited data is available on the long-term outcome of patients with increased cardiovascular event risk, treated with newer-generation durable polymer drug-eluting stents (DES).

Methods: We therefore assessed 3-year follow-up data of high-risk versus low- to intermediate-risk patients of the randomized DUTCH PEERS trial (NCT01331707). In both risk groups we also compared patients treated with Resolute Integrity versus Promus Element DES.

View Article and Find Full Text PDF

Aims: The aim of this report was to assess the three-year safety and efficacy of implanting newer-generation Resolute Integrity zotarolimus-eluting stents (ZES) versus PROMUS Element everolimus-eluting stents (EES) in all-comers.

Methods And Results: In the randomised, multicentre, investigator-initiated DUTCH PEERS trial, a total of 1,811 all-comers were 1:1 randomly assigned to treatment with ZES versus EES. A total of 1,293 patients (72%) were treated for complex lesions and 455 patients (25%) were treated for multiple lesions.

View Article and Find Full Text PDF

Background: Data on medium-term outcome of patients with acute coronary syndrome (ACS), treated with newer-generation durable polymer drug-eluting stents (DES) in severely calcified coronary lesions, are scarce. We aimed to assess the impact of severe coronary lesion calcification on clinical outcome of patients with ACS, treated with newer-generation DES.

Methods: The TWENTE and DUTCH PEERS randomized trials comprise 1779 ACS patients, who were categorized into patients with versus without severe target lesion calcification.

View Article and Find Full Text PDF

Background: The outcome of percutaneous coronary intervention with newer generation permanent polymer-coated drug-eluting stents (DES) in patients with severely calcified lesions is greatly unknown. We assessed the impact of severe lesion calcification on clinical outcome in patients with stable angina who underwent percutaneous coronary intervention with newer generation DES.

Methods: TWENTE and DUTCH PEERS randomized trials enrolled 1423 patients with stable angina, who were categorized into patients with versus without severe target lesion calcification.

View Article and Find Full Text PDF

Background: Percutaneous coronary intervention (PCI) in bifurcated lesions with second-generation drug-eluting stents (DES) was associated with increased myocardial infarction (MI) rates. Flexible stent designs that accommodate well to vessel tapering may be of benefit in challenging anatomies such as bifurcated target lesions, but so far data are scarce.

Methods: We analyzed the 2-year follow-up data of the DUTCH PEERS (TWENTE II) trial, which randomized 1811 all-comer patients to PCI with newer generation resolute integrity zotarolimus-eluting (Medtronic) or promus element everolimus-eluting stents (Boston Scientific).

View Article and Find Full Text PDF

Objectives: This study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts).

Background: For both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce.

View Article and Find Full Text PDF

Background: Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial.

Methods: In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands.

View Article and Find Full Text PDF

Background: Drug-eluting stents (DES) are increasingly used for the treatment of coronary artery disease. An optimized DES performance is desirable to successfully treat various challenging coronary lesions in a broad population of patients. In response to this demand, third-generation DES with an improved deliverability were developed.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=28 No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/lib/php/sessions)

Filename: Unknown

Line Number: 0

Backtrace: