Purpose: This paper aims to describe a straightforward, efficient, and reliable technique to simplify cannulation maneuvers during aortic branched endograft repair.
Technique: The suggested approach utilizes the Penumbra Neuron Select catheter, which combines diagnostic, sizing, and support capabilities in one. This has the potential to reduce procedural time and minimize the need for serial catheter and guidewire exchanges.
The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them.
View Article and Find Full Text PDFWe describe a successful case of hybrid revascularization of a totally occluded aortobifemoral bypass with retrograde use of the Rotarex S catheter (BD) and complete relining with a Gore Excluder iliac branch endoprosthesis (W.L. Gore & Associates).
View Article and Find Full Text PDFJ Cardiovasc Surg (Torino)
June 2023
Acute limb ischemia still represents a challenge for the contemporary vascular surgeon, representing an immediate threat for patients' limb but potentially also for the proper patient life in some settings. Technology recently evolved and focused on the treatment of such complex situation. Several devices are available as of today allowing a complete acute limb ischemia endovascular management, aiming to remove intraluminal material while leaving the possibility for treating the underlying pathology when needed.
View Article and Find Full Text PDFBackground: Mid-term durability of branches has already been established, and BF-branched and fenestrated endovascular repair has shown comparable results with open repair in the treatment of thoracoabdominal aortic aneurysms (TAAAs). Nevertheless, target vessel instability remains the most frequent adverse event after complex endovascular aortic repair. Type III endoleaks from directional branches have been reported with a low incidence, but risk factors for this complication have not been investigated yet.
View Article and Find Full Text PDFPurpose: To report a successful revascularization case using the Rotarex™S atherothrombectomy system in a recent iliac limb thrombosis, and chronic hypogastric stent obstruction after previous aortoiliac aneurysm endovascular repair (EVAR).
Case Report: A 72-year-old patient was treated for recent right iliac limb thrombosis and left iliac branch chronic hypogastric stent occlusion, 5 years after EVAR. A total endovascular approach, using both upper extremity and femoral vascular access, was settled with 2 Rotarex™S (6Fr and 10Fr) devices.
Background: Current guidelines indicate iliac-branched endografts (IBDs) as the ideal means to preserve pelvic perfusion during endovascular aortic repair. Because patient vascular anatomy represents the main limitation to extensive use of these devices, off-label application may be considered to expand the number of patients being treated. The aim of this study is to evaluate long-term outcomes obtained using the Cook ZBIS endograft in the treatment of aortoiliac aneurysms as per or outside manufacturer's instruction for use (IFU).
View Article and Find Full Text PDFAim of this paper is to describe a simple and helpful technique for challenging visceral vessel catheterization during complex aortic endovascular procedures. In demanding anatomies when standard visceral vessel cannulation maneuvers result ineffective, inflating a compliant balloon above the target arteries may allow easy and safe advancement of the introducer sheath inside selected vessel. This approach lowers the shear forces enhancing device pushability.
View Article and Find Full Text PDFPurpose: To describe a novel technique developed for the treatment of patients with thoracoabdominal aortic aneurysms having narrow aortic lumens using branched endografts.
Technique: When treating patients with a narrow aortic inner diameter with branched endografts, we propose a partial graft deployment leaving the distal portion of the device inside the delivery system with the aim of spare space and facilitate target vessel cannulation.
Conclusions: Partial endograft deployment could be considered in the case of expected difficulty associated with encumbrance deriving from the distal straight graft portion.
Background: A successful case of urgent type II thoracoabdominal aneurysm repair with an inner branched endograft conducted entirely through femoral accesses without the bailout possibility to achieve an upper extremity approach for bridging stents delivery is described.
Case Report: A 70-year-old male patient underwent hybrid treatment for a thoracic aortic aneurysm on complicated type B dissection in 2 steps. First, arch debranching with carotid-carotid-subclavian bypass and then ascending aortic replacement with reimplantation of the anonymous trunk plus TEVAR were performed.