Publications by authors named "Gianluca Ceravolo"

Background: Transcatheter mitral valve replacement (TMVR) is an alternative to conventional surgery to treat severe mitral disease but its use is limited by the risk of left ventricular outflow tract obstruction (LVOTO). Screening depends on ECG-gated computed tomography (CT) that is not widely available and requires contrast. We developed and validated a transthoracic echocardiographic (TTE) method to assess the risk of LVOTO after TMVR with the Tendyne System.

View Article and Find Full Text PDF

Cardiac contractility modulation (CCM) is a novel device-based therapy used in patients with HFrEF. CCM therapy is associated with an improvement in exercise tolerance, increased quality of life, reduced HF hospitalizations, and reverse remodelling of the left ventricle in patients with HFrEF. In this case, we report the clinical benefit of CCM in an older patient with advanced HFrEF due to ischemic dilated cardiomyopathy with frequent heart failure-related hospitalizations and poor quality of life despite optimal medical therapy.

View Article and Find Full Text PDF

Background: The venous access for the insertion of permanent leads of cardiac implantable electronic devices is often achieved by venous cutdown of the cephalic vein, or by "blind" puncture of the subclavian vein using anatomical landmarks, or by fluoroscopy-assisted methods.

Methods: We have retrospectively analyzed our clinical experience to verify the feasibility, the safety, and efficacy of the adoption of ultrasound-guided puncture/cannulation of the axillary vein for this purpose.

Results: Nine hundred eighty-seven leads were placed during 548 consecutive procedures, accessing the axillary vein in the infraclavicular area using real-time ultrasound guidance.

View Article and Find Full Text PDF

Introduction: Implantable cardiac monitor (ICM) is an established tool for the management of unexplained syncope and atrial fibrillation (AF) even if its accuracy of arrhythmia detection may be suboptimal. The aim of this study was to perform an intra-patient comparison of the diagnostic capability of ICM with a dual-chamber PM as a gold standard.

Methods: We included 19 patients with a previously implanted ICM (BioMonitor 2 Biotronik, Berlin, Germany), who received a dual-chamber PM for standard indications.

View Article and Find Full Text PDF

Background: The gold standard to treat cardiovascular implantable electronic devices (CIEDs) infections is the complete system removal. The aim of this retrospective analysis is to assess the feasibility and safety of an alternative conservative surgical system revision approach, to be applied in elderly patients who refused the extraction procedure, in case of no signs of systemic infection.

Methods: Between May 2009 and January 2019, we performed system revision of 25 patients (15 men and 10 women, median age 81 [IQ: 75-85] years) with negative blood culture, no signs of vegetation, who experienced CIED infections.

View Article and Find Full Text PDF

The implantable loop recorder (ILR), also known as insertable cardiac monitor (ICM) is a subcutaneous device used for diagnosing heart rhythm disorders. These devices have been strongly improved and miniaturized during the last years showing several reliable features along with the availability of remote monitoring which improves the diagnostic timing and the follow-up strategy with a potential reduction of costs for health care. The recent advent of injectable ILRs makes the procedure even easier and more tolerated by patients.

View Article and Find Full Text PDF

The rapid hyperemia evoked by muscle compression is short lived and was recently shown to undergo a rapid decrease even in spite of continuing mechanical stimulation. The present study aims at investigating the mechanisms underlying this attenuation, which include local metabolic mechanisms, desensitization of mechanosensitive pathways, and reduced efficacy of the muscle pump. In 10 healthy subjects, short sequences of mechanical compressions ( = 3-6; 150 mmHg) of the lower leg were delivered at different interstimulus intervals (ranging from 20 to 160 s) through a customized pneumatic device.

View Article and Find Full Text PDF