Publications by authors named "GianPaolo Sannino"

Purpose: The aim of this study was to estimate bleeding prevalence and postoperative peri-oral purpura after full-arch immediate implant rehabilitation according to the 'All-on-four' technique, in patients on different oral anticoagulant therapies (warfarin and rivaroxaban).

Materials And Methods: A total of 120 patients (47 women, 73 men, mean age 66.4 years) presented with edentulous or partially edentulous arches.

View Article and Find Full Text PDF

Purpose: This prospective study aims to evaluate the clinical outcomes of 'All-on-four' rehabilitations in controlled human immunodeficiency virus (HIV)-positive patients.

Materials And Methods: Edentulous patients requiring an implant prosthetic restoration of one or both jaws were enrolled in the present study. Each patient received at least one fixed full-arch prosthesis.

View Article and Find Full Text PDF

: The objective of this study was to compare conventional versus digital impressions for Full-Arch maxillary rehabilitations. : Patients selected for this study were treated with full-arch screw-retained rehabilitations supported by six immediately loaded dental implants. Patients have been scheduled randomly into control (conventional impression group, CIG) and test (digital impression group, DIG) groups respectively for a fully conventional workflow and a fully digital workflow.

View Article and Find Full Text PDF

The aim of this in vitro study was to compare the quality of digital workflows generated by different scanners (Intra-oral digital scanners (I.O.S.

View Article and Find Full Text PDF

Objectives: The aim of the study was to evaluate and compare digital and traditional prosthetic workflow for posterior maxillary restorations supported by an upright and a distally tilted implant at 3-year follow-up.

Materials And Methods: Twenty-four patients were treated in the posterior maxilla with 24 immediately loaded axial and 24 distally tilted implants supporting 3-unit or 4-unit screw-retained prostheses. Three months after initial loading patients were randomly stratified into two groups: definitive traditional impressions were carried out in the control group, while digital impressions were performed in the test group.

View Article and Find Full Text PDF

Purpose: To compare intrabony thermal changes induced by two different protocols for guided implant surgery during the whole drilling procedure.

Materials And Methods: Two protocols for guided implant placement were evaluated in vitro using artificial bone cylinders. The control protocol provided traditional metal sleeves and a standard drilling sequence composed of four cylindrical triflute drills (cutting surface length = 16 mm).

View Article and Find Full Text PDF

Objectives: The aim of this clinical study was to evaluate a new type of prefabricated bar system, supported by axial and tilted implants at 5-year follow-up.

Materials And Methods: Twenty-nine consecutive participants (19 females, 10 males) (mean age 61.4 years), edentulous in one or both jaws, with severe atrophy of the posterior regions, were treated according to the All-on-four® protocol with immediately loaded axial (64) and tilted (64) implants supporting complete-arch screw-retained prostheses (12 maxillary, 20 mandibular) featuring a prefabricated bar as framework.

View Article and Find Full Text PDF

Polyunsaturated fatty acids have been reported to play a protective role in a wide range of diseases characterized by an increased metalloproteinases (MMPs) activity. The recent finding that omega-3 and omega-6 fatty acids exert an anti-inflammatory effect in periodontal diseases has stimulated the present study, designed to determine whether such properties derive from a direct inhibitory action of these compounds on the activity of MMPs. To this issue, we investigated the effect exerted by omega-3 and omega-6 fatty acids on the activity of MMP-2 and MMP-9, two enzymes that actively participate to the destruction of the organic matrix of dentin following demineralization operated by bacteria acids.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate and compare the use of straight versus angulated abutments on tilted implants in the All-on-Four immediate function protocol.

Materials And Methods: A total of 85 patients (36 men and 49 women; mean age 56.5 years) with edentulous mandibles were treated according to the All-on-Four concept using computer-guided implant placement.

View Article and Find Full Text PDF

Purpose: The purpose of this retrospective investigation was to evaluate the use of a prefabricated bar system for immediately loaded implants placed and restored according to the All-on-Four concept with up to 24-month follow-up.

Materials And Methods: A total of 51 patients (31 males and 20 females; mean age 63.4 years) presented with edentulous or partially edentulous jaws with severe atrophy of the posterior regions.

View Article and Find Full Text PDF

Aim: To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use.

Methods: 20 packs of TFA small sequence (SybronEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy.

View Article and Find Full Text PDF

Objectives: The aim of the present study was to evaluate the cutting efficiency of two new reciprocating instruments, Twisted File Adaptive and WaveOne Primary.

Material And Methods: 10 new Twisted File Adaptive (TF Adaptive) (SybronEndo, Glendora, CA, USA) and 10 new WaveOne Primary files (Dentsply Maillefer, Ballaigues, Switzerland) were activated using a torque-controlled motor, respectively TFA motor (SybronEndo, Glendora, CA, USA) and Silver motor (VDW, Munich, Germany). The device used for the cutting test consisted on a mainframe to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare bone temperature changes during implant drilling with two drill designs employed in three different drilling sequences.

Materials And Methods: Two implant drill designs and three drilling sequences were evaluated in vitro using artificial bone cylinders. The evaluated drills were different only in the cutting-surface length (control, 16 mm; test, 4 mm).

View Article and Find Full Text PDF

This work investigated the antibacterial activity of 14 bonding agents to predict their ability to inhibit white-spot development during orthodontic treatment. Standardized, sterilized disks of each material were continuously rinsed (for up to 180 d) in a flow of sterile saline. At predetermined time points, the residual ability of each material to inhibit bacterial growth (determined by measuring the size of inhibition halos around disks placed onto appropriate culture media seeded with Streptococcus gordonii DSM6777, Streptococcus sanguinis DSM20567, Streptococcus mutans DSM20523, or Lactobacillus acidophilus DSM20079) and biofilm formation (determined by measuring the numbers of bacteria adherent to disks following incubation in appropriate broths) was tested in triplicate and compared with the baseline activities of freshly prepared materials.

View Article and Find Full Text PDF

Endodontic glide path is the creation of a smooth patency from canal orifice to apex, which can be performed manually or with small tapered NiTi rotary instruments. The use of stainless steel (SS) hand K-files inserted in a reciprocating handpiece can be a possible alternative to create a mechanical glide path. The aim of this study was to compare the cyclic fatigue resistance between SS K-files used in a reciprocating motion and NiTi rotary instruments in artificial curved canals.

View Article and Find Full Text PDF

This study aimed to investigate the influence of implant design (in terms of diameter, length, and thread shape), in-bone positioning depth, and bone posthealing crestal morphology on load transfer mechanisms of osseointegrated dental implants based on platform-switching concept. In order to perform an effective multiparametric comparative analysis, 11 implants different in dimensions and in thread features were analyzed by a linearly elastic 3-dimensional finite element approach, under a static load. Implant models were integrated with the detailed model of a maxillary premolar bone segment.

View Article and Find Full Text PDF
Article Synopsis
  • * These details could indicate potential health issues such as tissue degeneration, inflammation, or tumors, highlighting the need for automated analysis methods to assist physicians in accurate diagnoses.
  • * The study aims to showcase the effectiveness of fractal analysis in enhancing the evaluation of ultrasound images, specifically relating to submandibular diffuse pathology, and addressing the operator dependence of current clinical practices.
View Article and Find Full Text PDF

Aims: Apical extrusion of infected debris to the periradicular tissues is one of the principal causes of postoperative pain and discomfort. Recent researches have shown that reciprocating instrumentation techniques seem to significantly increase the amount of debris extruded beyond the apex and, consequently, the risk of postoperative pain. The goal of the present study was to evaluate and compare postoperative pain using three different nickel-titanium instrumentation techniques: a rotary crown-down technique using TF instruments (SybronEndo, Orange, Ca), a reciprocating single-file technique using WaveOne instruments (Maillefer DEntsply, Baillagues, CH), and a novel instrumentation technique (TF Adaptive, SybronEndo, Orange, Ca), using a unique, proprietary movement, combining reciprocation and continuous rotation.

View Article and Find Full Text PDF

Aim: The aim of the present study was to compare the resistance to cyclic fatigue of Hyflex® (Coltene-Whaledent, Allstatten, Switzerland) size 40 taper.04 nickel titanium instruments used in continuous rotation versus the use with a reciprocating motion. The null hypothesis was that different file motions had no influence on the lifetime of instruments subjected to a cyclic fatigue test.

View Article and Find Full Text PDF

The aim of this work was to study the biomechanical behavior of an All-on-4 implant-supported prosthesis through a finite element analysis comparing 3 different tilt degrees of the distal implants. Three-dimensional finite element models of an edentulous maxilla restored with a prosthesis supported by 4 implants were reconstructed to carry out the analysis. Three distinct configurations, corresponding to 3 tilt degrees of the distal implants (15°, 30°, and 45°) were subjected to 4 loading simulations.

View Article and Find Full Text PDF

The objective of this paper is to assess the role of conventional and high-frequency ultrasound in the evaluation of the depth of cutaneous skin cancer. The study was performed on 46 subjects, divided into 3 categories, according to their skin pathology [basal cell carcinoma (BCC), 18 subjects; superficial spreading melanoma (SSM), 8 subjects; nodular melanoma (NM), 20 subjects]. Conventional and high-frequency ultrasonographic measurements were performed in order to assess the thickness of the tumors and the vascularization degree.

View Article and Find Full Text PDF

Purpose: To evaluate the mechanical properties and behavior of a self-locking taper connection with three different techniques: three-dimensional finite element analysis (FEA), ultimate failure loading, and cyclic loading analysis.

Materials And Methods: The implant-abutment complex was embedded vertically in the center of an acrylic resin support block (Young's modulus > 3 GPa). All materials used in this study were assumed to be homogenous and isotropic, but while the resin was assumed to be linearly elastic, the titanium was assumed to have a multilinear behavior to better represent the implant system in its plastic phase and to compare as closely as possible the numeric simulation with the experimental tests.

View Article and Find Full Text PDF

Statement Of Problem: In the posterior maxilla, tooth loss is usually associated with alveolar bone resorption and sinus pneumatization, limiting the placement of implants without grafting procedures.

Purpose: The purpose of this study was to evaluate a minimally invasive treatment of the atrophic posterior maxilla, with axial and tilted implants and immediate loading. The research hypothesis was that the combination of a guided, minimally invasive approach and the biomimetic features of computer-aided design and computer-aided manufacturing (CAD/CAM) abutments would be an effective alternative to maxillary sinus floor augmentation procedures with reduced bone resorption around implants.

View Article and Find Full Text PDF