Publications by authors named "Gian-Maria A A Sordi"

In this paper we present the impact of variability, a surface source parameter, on the efficiency evaluation of surface contamination monitors. This study was based on two source uniformity correction methodologies and data from real surface source distributions. Surface source intensity distribution has been changed by rearranging the cells (portions of the active area of each LARS) while keeping the same source uniformity value.

View Article and Find Full Text PDF

Based on uniformity measurements of large-area reference sources used in calibration procedures of surface contamination monitors, an investigation was carried out to obtain a method that estimates the bias originated from surface source intensity distribution deviation from the ideal uniform distribution and corrects it. It relies on correcting the estimated instrument efficiency by applying correction factors driven from the uniformity distribution profiles of the sources used in calibration procedure. Simulations of the monitor calibration procedure are run for 2 distinct surface source distributions: the real and the ideally uniform distributions.

View Article and Find Full Text PDF

Radioactive patients may expose others after radiopharmaceutical administrations, and evaluation of the absorbed dose or exposure rates close to patients is important in keeping radiation doses as low as reasonably achievable. Two theoretical exposure models, point source and line source models, are frequently used to calculate exposure or dose rates without the support of actual measurements. If measurements of exposure rates were performed near patients, an experimental exposure model could be implemented.

View Article and Find Full Text PDF

Analytical geometric models for the bones of the knee region have been developed. A survey was done on real pieces to obtain the dimensions of the geometric sections used in each model. The dependence of the section dimensions on the bone length and the estimated dimensions of the bones for a 1.

View Article and Find Full Text PDF

In several countries, low-level radioactive wastes are treated and stored awaiting construction and operation of a final repository. In some cases, interim storage may be extended for decades requiring special attention regarding security issues. The International Atomic Energy Agency (IAEA) recommends segregation of wastes that may be exempted from interim storage or ultimate disposal.

View Article and Find Full Text PDF

The measurement of exposure rates is fundamentally important in the release of patients given radioactive materials and for keeping the exposures of others as low as reasonable achievable. Similar measurement methodologies have generally been used for point and extended sources, but this approach may lead to methodological errors in calculating radiation dose estimates. In this study, nuclear medicine patients who received high activities of Na131I for therapy were monitored using different measurement methodologies, and the results showed that the usual measurement performed at 1.

View Article and Find Full Text PDF

The evaluation of the absorbed dose from radioactive patients during the treatment of thyroid disease is an important factor in establishing precautions in these procedures, and the I retention/excretion by patients' bodies provides additional information to medical and radioprotection service. In 94 patients, the measurement of exposure rates was performed over 7 d following NaI administration, and the rates permitted the study of the dynamics of excretion and the potential dose evaluation. The administered activities ranged from 3.

View Article and Find Full Text PDF

Nuclear medicine procedures that use I activity represent significant sources of potential absorbed dose to medical staff, volunteers, and the general public. The potential exposures are due principally from exposures to excreted and retained activities in the patients' bodies. In general, exposure rate decreases in a simple exponential manner.

View Article and Find Full Text PDF