In recent decades, tissue engineering strategies have been proposed for the treatment of musculoskeletal diseases and bone fractures to overcome the limitations of the traditional surgical approaches based on allografts and autografts. In this work we report the development of a composite porous poly(dl-lactide-co-glycolide) scaffold suitable for bone regeneration. Scaffolds were produced by thermal sintering of porous microparticles.
View Article and Find Full Text PDFBackground: Biomechanical and histological properties of stapled bronchi with and without bovine pericardial matrix plus collagen reinforcement are analyzed.
Materials And Methods: Pneumonectomy with mechanical bronchial suture was performed in the swine model. Pigs were randomly assigned to three groups: three-row staplers without reinforcement (Traditional), with reinforcement (Buttressed) and control "wild type", non-resected normal bronchus (Normal).
The purpose of the study was to evaluate whether using only the semitendinosus as a tripled short graft would affect the electromechanical delay (EMD) of the knee flexors. EMD was evaluated in volunteers (N = 15) after they had undergone surgery for anterior cruciate ligament (ACL) reconstruction where the semitendinosus tendon alone was used as a graft. The results were compared with the intact leg and healthy controls (N = 15).
View Article and Find Full Text PDFObjective: The aim of this study on human cadavers was to compare the accuracy of two electronic apex locators (EALs) Dentaport ZX (J. Morita Corporation, Tokyo, Japan) and Raypex 6 (VDW, Munich, Germany).
Materials And Methods: Twenty-two single rooted teeth of four human cadaver heads were scheduled for this study.
Technol Health Care
January 2017
Background: Biomechanical behaviour evaluation of a suture is an important information for the surgeon to choose the best technique to perform.
Objective: To assess the biomechanical behavior of the native and mechanically sutured bronchi.
Methods: Ten bronchi were harvested from slaughtered pigs and then randomly separated in two groups, a control intact group and a sutured group where specimens were cut in half and sutured, to evaluate mechanical properties during a tensile test using a loading frame machine.
Background: Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement.
View Article and Find Full Text PDF