This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites.
View Article and Find Full Text PDFInt J Periodontics Restorative Dent
August 2010
The purpose of this study was to present a new laboratory technique for cementable implant-supported restorations and to evaluate its efficacy in reducing chair time for both patients and clinicians, while maintaining the precision of an indirect procedure for crown fabrication. The technique consisted of the duplication of the implant portion of a working cast prepared using double-pour or plastic base die systems for single or multiple crowns. For this purpose, a flask previously intended for the production of ceramic inlays and onlays was used.
View Article and Find Full Text PDFBackground: The dual acid-etched (DAE) implant was commercially introduced in 1996 with a hybrid design incorporating a machined surface in the coronal region from approximately the third thread to the seating surface. This design was intended to reduce the risks of peri-implantitis and other related soft tissue complications that were reported for implants with surface roughness in the coronal region. The objective of this prospective, randomized-controlled clinical trial was to determine the incidence of peri-implantitis for a fully etched implant with the DAE surface extending to the implant platform.
View Article and Find Full Text PDFClin Implant Dent Relat Res
May 2010
Background: Clinical studies reporting immediate loading of endosseous implants for edentulous cases and for fixed partial restorations have been well documented with satisfactory survival rates. Implants with a recently developed, nanometer-scale surface topography (NanoTite, BIOMET 3i, Palm Beach Gardens, FL, USA), created by discrete crystalline depositions (DCD) of calcium phosphate nano-crystals onto a dual acid-etched (DAE) surface, show enhanced early fixation in preclinical studies when compared with DAE-surfaced implants. These outcomes suggest DCD-surfaced implants may be advantageous for immediate loading approaches.
View Article and Find Full Text PDFInt J Oral Maxillofac Implants
February 2006
Purpose: In this multicenter study, the performance of Osseotite implants after a 1-stage surgery and abbreviated healing period of 2 months is reported. The implants were followed for up to 5 years.
Materials And Methods: Partially or completely edentulous patients treated at 10 private practice centers were included in the study.
The use of expanded polytetrafluoroethylene (ePTFE) membranes in the treatment of mucogingival problems such as gingival recession, has been recently described. The major issues raised dealt with creating and maintaining space under the membrane and designing a flap that could be coronally positioned and at the same time capable of maintaining a good blood supply. The authors proposed the use of a trapezoidal flap and some technical space-making solutions, such as the use of a suturing technique and different metal structures to support the membranes.
View Article and Find Full Text PDF