Radiat Environ Biophys
November 2024
In addition to specific dosimetric properties of protons, their higher biological effectiveness makes them superior to X-rays and gamma radiation, in radiation therapy. In recent years, enrichment of tumours with metallic nanoparticles as radiosensitizer agents has generated high interest, with several studies attempting to confirm the efficacy of nanoparticles in proton therapy. In the present study Geant4 Monte Carlo (MC) code was used to quantify the increased nanoscopic dose deposition of 50 nm metallic nanoparticles including gold, bismuth, iridium, and gadolinium in water upon exposure to 5, 25, and 50 MeV protons.
View Article and Find Full Text PDFThis study investigates the photon interaction mechanism of various small molecule radiosensitizers, including Hydrogen Peroxide, Nimorazole, 5-Fluorouracil, NVX-108, and others, using the MCNP 6.3 Monte Carlo simulation code. The simulations focused on quantifying the linear attenuation coefficients, mean free path, and accumulation factors of these radiosensitizers, as well as their interactions in a simulated spherical water phantom irradiated with a 100 keV mono-energetic X-ray source.
View Article and Find Full Text PDFThis study provides a comprehensive evaluation of the occupational radiation exposure faced by healthcare professionals during Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures. Utilizing an anthropomorphic RANDO phantom equipped with Thermoluminescent Dosimeters (TLDs), we replicated ERCP scenarios to measure radiation doses received by medical staff. The study meticulously assessed radiation exposure in various corresponding body regions typically occupied by medical staff during ERCP, with a focus on eyes, thyroid, hands, and reproductive corresponding organ regions.
View Article and Find Full Text PDFIn this study, it was aimed to evaluate the effect of ethanol extract of (AM) leaves in the prevention of brain damage caused by ionizing radiation (IR). This study was conducted in the Experimental Animal Research Unit of a university with 28 adults female Wistar Albino rats. The experimental groups were as follows: Control group (n = 8), AM group (n = 6), IR group (n = 8), AM + IR group (n = 6).
View Article and Find Full Text PDFWe report the functional assessment of tungsten (VI) oxide on gamma-ray attenuation properties of 60SbO-(40-x)NaPO-xWO antimony glasses. The elemental mass-fractions and glass-densities of each glass sample are specified separately for the MCNPX Monte Carlo code. In addition to fundamental gamma absorption properties, Transmission Factors throughout a broad radioisotope energy range were measured.
View Article and Find Full Text PDFRadiat Phys Chem Oxf Engl 1993
October 2023
Introduction: CTPA stands for computed tomography pulmonary angiography. CTPA is an X-ray imaging that combines X-rays and computer technology to create detailed images of the pulmonary arteries and veins in the lungs. This test diagnoses and monitors conditions like pulmonary embolism, arterial blockages, and hypertension.
View Article and Find Full Text PDFIntroduction: A lead-acrylic protective screen is suggested to reduce radiation exposure to the unexposed breast during mammography. The presence of toxic lead in its structure may harm the tissues with which it comes in contact. This study aimed to design a CdO-rich quaternary tellurite glass screen (C40) and evaluate its efficiency compared to the Lead-Acrylic protective screen.
View Article and Find Full Text PDFWe report the critical optical properties such as Average Visible Transmittance (AVT), colour, Color Rendering Index (CRI), and Correlated Color Temperature (CCT) of a multicomponent glass system with a nominal composition of 50TeO-30BO-(20-x)LiO-xCeO (x = 0,0.5,1,2,3,4,5,10,15,20 mol%). Various advanced theoretical approaches as well as calculations are utilized in terms of determining the optical properties of studied glasses.
View Article and Find Full Text PDFQuality assurance is an integral part of brachytherapy. Traditionally, radiographic films have been used for source position verification, however, in many clinics, computerized tomography simulators have replaced conventional simulators, and computerized radiography systems have replaced radiographic film processing units. With these advances, the problem of controlling source position verification without traditional radiographic films and conventional simulators has appeared.
View Article and Find Full Text PDFThis study's primary objective is to provide the preliminary findings of novel research on the design of Indium (III) oxide-reinforced glass container that were thoroughly developed for the purpose of a nuclear material container for transportation and waste management applications. The shielding characteristics of an Indium (III) oxide-reinforced glass container with a certain elemental composition against the Co radioisotope was thoroughly evaluated. The energy deposition in the air surrounding the designed portable glass containers is measured using MCNPX general-purpose Monte Carlo code.
View Article and Find Full Text PDFIntroduction: We report the breast and chest radiation dose assessment for mammographic examinations using a three-layer heterogeneous breast phantom through the MCNPX Monte Carlo code.
Methods: A three-layer heterogeneous phantom along with compression plates and X-ray source are modeled. The validation of the simulation code is obtained using the data of AAPM TG-195 report.
: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its performance to that of lead acrylic. : A three-layer heterogeneous-breast phantom was developed, using the MCNPX (version 2.
View Article and Find Full Text PDFThe nuclear spectroscopy method has long been used for advanced studies on nuclear physics. In order to decrease costs and increase the efficiency of nuclear radiation investigations, quick and efficient solutions are required. The purpose of this research was to calculate the whole energy peak efficiency values for a range of gamma-ray energies, from 30.
View Article and Find Full Text PDFIn this study, three different sliding bearing alloy samples were investigated in terms of their performance on attenuation characteristics and behavioral attitudes under 0.015-15 MeV gamma-ray exposure. Accordingly, different types of advanced calculation methods were utilized to calculate the radiation shielding parameters.
View Article and Find Full Text PDFThe direct influence of La ions on the gamma-ray shielding properties of cobalt-doped heavy metal borate glasses with the chemical formula 0.3CoO-(80-x)BO-19.7PbO-xLaO: x = 0, 0.
View Article and Find Full Text PDFThis study aimed to perform an investigation for the potential implementation of bismuth silicate glasses as novel shield equipment instead of ordinary shields in nuclear medicine facilities. Accordingly, a group of BiO reinforced silicate glass system were investigated and compared with ordinary shields in terms of their gamma-ray attenuation properties in diagnostic nuclear medicine radioisotope energies emitted from Tc, In, Ga, I, I, Kr, Tl, Xe. Mass attenuation coefficient (μm) results for glass samples were calculated comparatively with the XCOM program and MCNPX code.
View Article and Find Full Text PDFWe aimed to determine the contribution of various trivalent ions like Al and rare-earths (Y, Nd, Sm, Eu) on resistance behaviors of different types of bismo-borate glasses. Accordingly, eight different bismuth borate glasses from the system: 40BiO-59BO-1TvO (where Tv = Al, Y, Nd, Sm, and Eu) and three glasses of (40BiO-60BO; 37.5BiO-62.
View Article and Find Full Text PDFIn this study, brass (Cu/Zn) reinforced polymer composites with different proportions of brass powders were fabricated. Different types of nuclear shielding parameters such as mass and linear attenuation coefficients, radiation protection efficiency, half and tenth value layers, and effective atomic number values were determined experimentally and theoretically in the energy range of 0.060-1.
View Article and Find Full Text PDFIn this study, a group of heavy metal oxide glasses with a nominal composition of 55BO + 19.5TeO + 10KO + (15-x) PbO + xAlO + 0.5EuO (where x = 0, 2.
View Article and Find Full Text PDFThe radiation shielding characteristics of samples from two TeO and SbO-based basic glass groups were investigated in this research. TeO and SbO-based glasses were determined in the research as six samples with a composition of 10WO-(x)MoO-(90 - x)(TeO/SbO) (x = 10, 20, 30). A general purpose MCNPX Monte Carlo code and Phy-X/PSD platform were used to estimate the radiation shielding characteristics.
View Article and Find Full Text PDFThe performance of keV neutrons based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setups have been observed to improve by enclosing its neutron source inside the moderator. The keV neutrons were produced via (7)Li(p,n) reaction and (3)H(p,n) reactions. For the two PGNAA setups, the maximum intensity of the prompt gamma-ray yield was observed for a 5cm long moderator with the neutron source positioned at a distance of 0.
View Article and Find Full Text PDF