Publications by authors named "Gerson Rosenberg"

The Pennsylvania State University (PSU) Child Pump, a centrifugal continuous-flow ventricular assist device (cf-VAD), is being developed as a suitable long-term implantable device for pediatric heart failure patients between 10 and 35 kg, body surface area (BSA) of 0.5-1.2 m 2 , 1-11 years of age, and requiring a mean cardiac output of 1.

View Article and Find Full Text PDF

The loss of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in aortic stenosis (AS) and continuous-flow left ventricular assist devices (cf-LVADs) is believed to be associated with high turbulent blood shear. The objective of this study is to understand the degradation mechanism of HMWM in terms of exposure time (kinetic) and flow regime (dynamics) within clinically relevant pathophysiologic conditions. A custom high-shear rotary device capable of creating fully controlled exposure times and flows was used.

View Article and Find Full Text PDF

Current generation continuous flow assist devices to operate at a fixed speed, which limits preload response and exercise capacity in left ventricular assist device (LVAD) patients. A feedback control system was developed to automatically adjust pump speed based on direct measurements of ventricular loading using a custom cannula tip with an integrated pressure sensor and volume-sensing conductance electrodes. The input to the control system is the integral of the left ventricular (LV) pressure versus conductance loop (PGA) over each cardiac cycle.

View Article and Find Full Text PDF

We have miniaturized and optimized our implantable rotary blood pump developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the miniaturized Fontan circulation assist device (mini-FCAD) during 30-day sheep studies (n = 5). A complete right heart bypass was performed and all return flow was supported by the pump.

View Article and Find Full Text PDF

Supraphysiologic high shear stresses created in calcific aortic stenosis (AS) are known to cause hemostatic abnormalities, however, the relationship between the complex blood flows over the severity of AS and hemostatic abnormalities still remains unclear. This study systematically characterized the blood flow in mild, moderate, and severe AS. A series of large eddy simulations (LES) validated by particle image velocimetry were performed on physiologically representative AS models with a peak physiologic flow condition of 18 liter per minute.

View Article and Find Full Text PDF

Despite the prevailing use of the continuous flow left ventricular assist devices (cf-LVAD), acquired von Willebrand syndrome (AvWS) associated with cf-LVAD still remains a major complication. As AvWS is known to be dependent on shear stress (τ) and exposure time (t ), this study examined the degradation of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in terms of τ and t . Two custom apparatus, i.

View Article and Find Full Text PDF

The existence of acquired von Willebrand syndrome (AVWS) in patients with continuous flow left ventricular assist devices (LVADs) is well documented and has been verified by numerous investigators. AVWS has not been observed to occur in pulsatile devices such as the SynCardia total artificial heart (TAH), the HeartMate XVE, and the Thoratec pulsatile ventricular assist device (PVAD) used as a single pump. AVWS can also occur in patients with aortic stenosis, ventricular septal defect, mitral stenosis, and patent ductus arteriosus.

View Article and Find Full Text PDF

An implantable rotary blood pump was developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the pump in vivo in a 30 day sheep study. Pump speed was set at 3,900 rpm for the duration of the study, and pump power was between 4.

View Article and Find Full Text PDF

The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK).

View Article and Find Full Text PDF

Despite recent breakthroughs in targeted- and immune-based therapies, rapid development of drug resistance remains a hurdle for the long-term treatment of patients with melanoma. Targeting metastatically spreading circulating tumor cells (CTCs) may provide an additional approach to manage melanoma. This study investigates whether targeting cholesterol transport in melanoma CTCs can retard metastasis development.

View Article and Find Full Text PDF

Reynolds shear stress (RSS) has served as a metric for the effect of turbulence on hemolysis. Forstrom (1969) and Sallam and Hwang (1984) determined the RSS threshold for hemolysis to be 50,000 and 4,000 dyne/cm, respectively, using a turbulent jet. Despite the order of magnitude discrepancy, the threshold by Sallam and Hwang has been frequently cited for hemolytic potential in blood pumps.

View Article and Find Full Text PDF

We compare the velocity and shear obtained from particle image velocimetry (PIV) and computational fluid dynamics (CFD) in a pulsatile ventricular assist device (VAD) to further test our thrombus predictive methodology using microscopy data from an explanted VAD. To mimic physiological conditions , a mock circulatory loop is used with a blood analog that matched blood's viscoelastic behavior at 40% hematocrit. Under normal physiologic pressures and for a heart rate of 75 bpm, PIV data is acquired and wall shear maps are produced.

View Article and Find Full Text PDF

Repeated bolus intravenous (IV) administration of large doses of beta-lactams and aminoglycosides has previously been associated with the development of eosinophilic and occlusive arterial lesions limited to the lungs in calves. Reviewing 13 years worth of records from left ventricular assist device implantation studies, morphologically identical segmental arterial lesions were present in 32 of the 56 calves receiving IV antibiotics, affecting lungs (6/50), kidneys (12/56), or lungs and kidneys (14/50). In 16 of these calves, renal arterial lesions spatially colocalized with renal cortical infarctions.

View Article and Find Full Text PDF

Evaluation of thrombogenicity is a critical component in the preclinical testing and development of blood pumps. Left ventricular assist devices (LVADs), because of their device routing, can produce thromboembolic showers to the kidney resulting in renal cortical ischemia or infarctions. Although postmortem evaluation of renal pathology can confirm ischemic events and infarctions, there are no validated and highly sensitive real-time measures of renal ischemia in the preclinical models.

View Article and Find Full Text PDF

Due to improved reliability and reduced risk of thromboembolic events, continuous flow left ventricular assist devices are being used more commonly as a long term treatment for end-stage heart failure. As more and more patients with these devices are leaving the hospital, a reliable control system is needed that can adjust pump support in response to changes in physiologic demand. An inlet pressure sensor has been developed that can be integrated with existing assist devices.

View Article and Find Full Text PDF

The Penn State Infant Ventricular Assist Device (VAD) is a 12-14 ml stroke volume pneumatically actuated pump, with custom Björk-Shiley monostrut valves, developed under the National Heart, Lung, and Blood Institute Pediatric Circulatory Support program. In this report, we describe the seven most recent chronic animal studies of the Infant VAD in the juvenile ovine model, with a mean body weight of 23.5 ± 4.

View Article and Find Full Text PDF

This article summarizes the use of computational fluid dynamics (CFD) to design a novel suspended Tesla left ventricular assist device. Several design variants were analyzed to study the parameters affecting device performance. CFD was performed at pump speeds of 6500, 6750, and 7000 rpm and at flow rates varying from 3 to 7 liters per minute (LPM).

View Article and Find Full Text PDF

A Tesla type continuous flow left ventricular assist device (VAD) has been designed by Penn State and Advanced Bionics, Inc. (ABI). When a continuous flow device is used, care must be taken to limit low pressures in the ventricle, which can produce an obstruction to the inlet cannula or trigger arrhythmias.

View Article and Find Full Text PDF

The design and initial test results of a new passively suspended Tesla type left ventricular assist device blood pump are described. Computational fluid dynamics (CFD) analysis was used in the design of the pump. Overall size of the prototype device is 50 mm in diameter and 75 mm in length.

View Article and Find Full Text PDF

This investigation determined the ages and weights of children that could be supported with 12 and 25 ml Penn State pediatric ventricular assist devices (PVADs) using 6, 8, and 10 mm outlet cannulas and grafts. Future patients will be matched to devices based on cardiac output (CO) and ascending aortic diameter (AA). These were calculated for children 0-10 years with regression formulas given as clinical standards [<5 kg, CO = 0.

View Article and Find Full Text PDF