Background: Coronary artery disease (CAD) is a leading cause of death and disability. Conventional non-invasive diagnostic modalities for the detection of stable CAD at rest are subject to significant limitations: low sensitivity, and personal expertise. We aimed to develop a reliable and time-cost efficient screening tool for the detection of coronary ischemia using machine learning.
View Article and Find Full Text PDFCurrent left ventricular assist devices (LVADs) differ with respect to their pump characteristics as described by the pump characteristic curve (also called HQ-curve). Pressure sensitive LVADs depict a flat characteristic curve while most available LVADs have a steep, less pressure sensitive characteristic curve. This in vitro study investigated the effect of LVAD pressure sensitivity with a focus on the afterload of the right ventricle (RV) which is one out of many factors influencing right heart failure (RHF).
View Article and Find Full Text PDFBackground: Congestive hepatopathy (CH) and acute liver failure (ALF) are common among biventricular heart failure patients. We sought to evaluate the impact of total artificial heart (TAH) therapy on hepatic function and associated clinical outcomes.
Methods: A total of 31 patients received a Syncardia Total Artificial Heart.
Currently available diagnostic modalities for the detection of graft vasculopathy following orthotopic heart transplantation are subject to various restrictions. We hypothesized that cardiogoniometry, a novel non-invasive diagnostic tool for the detection of atherosclerotic coronary vessel disease, is applicable in the graft vasculopathy setting. Cardiogoniometric results were obtained during routine follow-up in 49 consecutive, unselected heart transplant recipients and then retrospectively correlated blindly by an independent reader to recent angiographic findings.
View Article and Find Full Text PDFNocardia has emerged as an important opportunistic pathogen, especially in organ transplant recipients. Heart transplant (HT) recipients initially had an especially high rate of Nocardia infection, but this could be reduced by the routine use of cyclosporine. Our objective was to clarify the prevalence and presentation of Nocardiosis in HT recipients in a retrospective cross-sectional analysis.
View Article and Find Full Text PDFDespite downsizing, implantation technique of the 50-cm(3) SynCardia Total Artificial Heart and settings of the Companion driver remain unchanged. Owing to the absence of de-airing nipples, de-airing procedure is even more crucial and has to be performed carefully.
View Article and Find Full Text PDFThe 50-cc SynCardia total artificial heart is designed to facilitate orthotopic replacement of the native ventricles in patients with a body surface area below 1.7 m(2) in need of long-term circulatory support as a result of end-stage biventricular heart failure. We describe the implementation of this technology in a female patient with irreversible cardiogenic shock on the grounds of acute myocardial infarction and chronic ischemic cardiomyopathy.
View Article and Find Full Text PDFCoagulation disorders and an immune-altered state are common among total artificial heart patients. In this context, we sought to evaluate the safety of percutaneous dilatational tracheostomy in cases of prolonged need for mechanical ventilatory support. We retrospectively analysed the charts of 11 total artificial heart patients who received percutaneous dilatational tracheostomy.
View Article and Find Full Text PDFCardiogoniometry is an electrocardiographic and vectorcardiographic method utilizing computer-assisted analysis of cardiac potentials focusing on T-wave abnormalities resulting from myocardial malperfusion. We describe a case of diagnosis of obstructive coronary artery disease with this method and discuss the possible implications for the clinical setting.
View Article and Find Full Text PDFObjectives: Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart.
View Article and Find Full Text PDFBackground: Cold ischemia associated with cold static storage is an independent risk factor for primary allograft failure and survival of patients after orthotopic heart transplantation. The effects of normothermic ex vivo allograft blood perfusion on outcomes after orthotopic heart transplantation compared to cold static storage have been studied.
Methods: In this prospective, nonrandomized, single-institutional clinical study, normothermic ex vivo allograft blood perfusion has been performed using an organ care system (OCS) (TransMedics, Andover, MA, USA).
Interact Cardiovasc Thorac Surg
June 2014
The SynCardia total artificial heart is currently used as a bridge to transplantation therapy in cases of irreversible, acute or chronic, biventricular heart failure. We describe the implementation of this technology in the context of destination therapy in a patient with an end-stage heart failure on grounds of primary amyloidosis.
View Article and Find Full Text PDFObjectives: Real-time monitoring of the aortic valve function and the loading state of the left ventricle (LV) during mechanical circulatory support is essential. Therefore, we developed a system that determines accurately the aortic valve closing moment based on integrals derived from the pump inlet pressure and the pump power [pressure-power area (PPA)].
Methods: A Deltastream diagonal pump was implanted in 10 healthy Rhoen sheep.
We report the case of a 64-year old Caucasian male patient with a tear of the left ventricular driveline just above the driveline-air tube junction. We describe the repair technique and the necessary set of tools.
View Article and Find Full Text PDFBackground: Good anatomical compatibility is an important aspect in the development of cardiovascular implants. This work analyzes the interaction of the pump unit of an electrically driven pulsatile Total Artificial Heart (TAH) and the mediastinum. For an adequate compliance, both overall dimensions and alignment of inlets and outlets must be matched.
View Article and Find Full Text PDFWe report the case of a 55 years old caucasian male patient with cardiogenic shock due to an extended myocardial infarction who underwent SynCardia Total Artificial Heart implantation and veno-venous extracorporeal membrane oxygenation with a bicaval dual-lumen cannula for the treatment of adult respiratory distress syndrome.
View Article and Find Full Text PDF