Publications by authors named "Gernot Roessler"

Background: The aim of this study was to compare the outcome of implantation of a XEN45 Gel Stent with the outcome of implantation of a Preserflo MicroShunt in a matched-pair analysis in eyes being naïve to filtering surgery.

Methods: In this comparative, retrospective study, 50 eyes that had undergone XEN45 Gel Stent implantation were compared with 50 eyes after Preserflo implantation. Follow-up was at least 6 months, and surgical success was measured by criteria A (IOP < 21 mmHg, IOP reduction >20%, no repeat surgery); criteria B (IOP < 18 mmHg, IOP reduction >20%, no repeat surgery); and criteria C (IOP ≤15 mmHg, IOP reduction ≥40%, no repeat surgery).

View Article and Find Full Text PDF

Purpose: To determine differing outcomes among either phakic or pseudophakic patients who received standalone XEN45 Gel Stent (Allergan, an AbbVie Company, CA, USA) implantation and patients who underwent combined surgery with phacoemulsification.

Methods: This retrospective single-center study involved 180 eyes of 180 participants who underwent XEN45 Gel Stent implantation, of which 60 eyes received combined surgery with phacoemulsification (combined group). Standalone stent implantation was performed on 60 phakic (phakic group) and on 60 pseudophakic eyes (pseudophakic group).

View Article and Find Full Text PDF

Background: To investigate in combined iStent inject implantation with phacoemulsification carried out bilaterally, whether intraocular pressure (IOP)-lowering effectiveness in the first eye has a predictive potential for the outcome of the second eye in primary open-angle glaucoma (POAG).

Methods: This retrospective study included 72 eyes from 36 participants, who underwent trabecular bypass implantation in combination with cataract surgery at two study centres (Düsseldorf, Cologne). Surgery was classified as either 'success' or 'failure' based on three scores: IOP at follow-up <21 mmHg (Score A) or IOP < 18 mmHg (Score B), with an IOP reduction >20% respectively, without re-surgery and IOP ≤ 15 mmHg with an IOP reduction ≥40%, without re-surgery (Score C).

View Article and Find Full Text PDF

Background/purpose: To determine anatomical success and best-corrected visual acuity after secondary surgery with heavy silicone oil tamponade in patients with persistent full-thickness macular holes.

Methods: In this retrospective study, 63 eyes with persistent full-thickness macular holes after primary pars plana vitrectomy and internal limiting membrane peeling underwent secondary surgery with heavy silicone oil tamponade. Macular spectral domain optical coherence tomography and best-corrected visual acuity measurements were performed during the follow-up.

View Article and Find Full Text PDF

: Visual prostheses, epiretinal stimulating arrays, are a promising therapy in treating retinal dystrophies and degenerations. In the wake of a new generation of devices, an innovative method for epiretinal fixation of stimulator arrays is required. We present the development of tailor-made bioadhesive peptides (peptesives) for fixating epiretinal stimulating arrays omitting the use of traumatic retinal tacks.

View Article and Find Full Text PDF

Introduction: We report a case of endophthalmitis and endocarditis that developed after stent perforation following a XEN45 Gel Stent implantation 10 months ago.

Case Report: A 79-year-old man was referred to our hospital because of endophthalmitis of the right eye. The patient had undergone XEN45 Gel Stent implantation in the same eye 10 months ago.

View Article and Find Full Text PDF

Background: To determine whether the outcome of the first eye may serve as a predictor for intraocular pressure (IOP)-lowering effectiveness in the second eye following bilateral ab interno trabeculectomy.

Methods: This retrospective single-centre study included 168 eyes from 84 participants, who underwent combined Trabectome surgery with phacoemulsification cataract surgery in a hospital setting. The clinical endpoint was defined as either 'success' or 'failure' based on four separate scores at the longest follow-up time point: IOP at follow-up <21 mm Hg (Score A) or IOP < 18 mm Hg (Score B), without re-surgery and IOP reduction >20%; IOP ≤15 mm Hg without re-surgery and IOP reduction ≥40% (Score C); and the sole absence of re-surgery according to the discretion of the surgeon (Score D).

View Article and Find Full Text PDF

Purpose: We assessed the accuracy of lens power calculation in highly myopic patients implanting plus and minus intraocular lenses (IOL).

Methods: We included 58 consecutive, myopic eyes with an axial length (AL) > 26.0 mm, undergoing phacoemulsification and IOL implantation following biometry using the IOLMaster 500.

View Article and Find Full Text PDF

Precis: The XEN45 Gel Stent can be implanted after failed trabeculectomy without disadvantages compared with primary implantation.

Purpose: We aimed to compare the outcomes of XEN45 Gel Stent implantation in pseudophakic eyes after failed trabeculectomy and in pseudophakic eyes without other previous surgeries.

Patients And Methods: In this retrospective study, we included 30 pseudophakic eyes of 30 patients who underwent XEN45 Gel Stent implantation after failed trabeculectomy (trabeculectomy group) and 60 eyes of 60 patients with primary XEN45 Gel Stent implantation (control group).

View Article and Find Full Text PDF

The published online version contains mistake as the author's first name and last name have been interchanged as "Hild Matthias" instead of "Matthias Hild".

View Article and Find Full Text PDF

Purpose: This study investigates the long-term intraocular pressure (IOP) lowering potential, risk profile and success rate of a triple procedure comprising phacoemulsification, trabecular aspiration and trabectome (Microsurgical Technology, Redmond, WA, USA) for treating exfoliation glaucoma.

Methods: A total of 117 eyes of 117 patients with exfoliation glaucoma underwent a combination of phacoemulsification, trabectome and trabecular aspiration. They were followed up for up to 7 years.

View Article and Find Full Text PDF

Purpose: We conducted a retrospective study to evaluate the intraocular pressure (IOP) lowering effect, the success rates, and the risk of bleeding events of patients receiving an iStent inject combined with phacoemulsification under anticoagulation therapy compared with a matched control group.

Methods: In this retrospective study, sixty-four eyes underwent an iStent inject implantation combined with phacoemulsification at two centers. Thirty-two eyes received surgery while under anticoagulation therapy, and another thirty-two eyes served as a control group matched for visual acuity, IOP, and medication score.

View Article and Find Full Text PDF

Purpose: To determine ocular side effects of vardenafil with special regard to color vision and retinal function.

Methods: This was a single center, randomized, double-blind, placebo-controlled, twofold crossover study with an administration of a single oral dose of two 20 mg tablets of BAY 38-9456 (vardenafil hydrochloride) or corresponding placebo in 24 healthy male subjects. Ocular investigations included Farnsworth-Munsell D100 color vision test, electroretinogram, and basic ophthalmological examinations like visual acuity, visual field, and slit-lamp of anterior segment and fundus.

View Article and Find Full Text PDF

Importance: To investigate the long-term safety of a novel intraocular telemetric pressure sensor.

Background: Acquisition of accurate intraocular pressure (IOP) data is vital for sufficient medical care of glaucoma patients. Non-invasive self-tonometry with a telemetric IOP sensor can provide important information regarding the individual IOP profile.

View Article and Find Full Text PDF

Purpose: The aim of the study was to investigate the agreement of intraocular pressure (IOP) measurement using dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in eyes after vitrectomy with intraocular gas endotamponade, in eyes after vitrectomy with no tamponade, and in controls.

Methods: In this prospective comparative study IOP was measured with GAT and DCT in 41 eyes with gas endotamponade (sulfur hexafluoride 20%) 1 to 3 days after vitrectomy, in 32 postvitrectomy eyes with intraocular water, and in 46 control eyes with no history of glaucoma or intraocular surgery. Corneal pachymetry and axial length measurements were additionally performed.

View Article and Find Full Text PDF

Purpose: We investigated the safety of a telemetric IOP sensor and the accuracy of its IOP measurements in six patients with open-angle glaucoma and cataract.

Methods: The study design was a prospective, single-center clinical trial. Here we present 1-year follow-up data.

View Article and Find Full Text PDF

Introduction: In addition to measurement errors, individual anatomical conditions could be made responsible for unexpected prediction errors in the determination of the correct intraocular lens power for cataract surgery. Obviously, such anatomical conditions might be relevant for both eyes. The purpose of this study was to evaluate whether the postoperative refractive error of the first eye has to be taken in account for the biometry of the second.

View Article and Find Full Text PDF

Background: The purpose of this study was to examine retinal recovery processes to pographically by the application of three flash sequences with specific interstimulus intervals.

Methods: Twelve healthy subjects underwent multifocal electroretinography with a light-emitting diode stimulator. Every flash sequence consisted of three flashes with 25 msec between the first and the second flash and 35 msec between the second and the third flash.

View Article and Find Full Text PDF

Purpose: To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes.

Methods: Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery.

View Article and Find Full Text PDF

Purpose: The relationship between number of laser burns of cyclophotocoagulation (CPC) and intraocular pressure (IOP) reduction is unknown. This animal model was established to reveal a possible dose-response-relationship between the number of applied laser burns and the IOP lowering effect.

Methods: 30 chinchilla bastard rabbits were divided into 5 groups and treated with either 1, 5, 10, 20, or 30 CPC burns, respectively.

View Article and Find Full Text PDF

Purpose: Blue-yellow visual-evoked potentials (BY-VEPs) may be used for diagnostics of functional ganglion cell damage in glaucoma and other ocular diseases. In this study we investigated the impact of lenticular opacities on BY- and standard pattern reversal VEPs by examining patients before and after cataract surgery.

Methods: Eighteen patients with moderate cataract were included in a prospective study.

View Article and Find Full Text PDF

Purpose: To demonstrate development and complications in heavy silicone oil (HSO) surgery in 100 eyes following primary vitreoretinal surgery.

Methods: 100 eyes were included in this retrospective study that underwent vitreoretinal surgery using HSO as endotamponade. Indication diagnoses were retinal detachments (n = 76), complicated macular holes (MH) (n = 20), and others (n = 4).

View Article and Find Full Text PDF

Background: Retinal implants have been developed to treat blindness causing retinal degenerations such as Retinitis pigmentosa (RP). The retinal stimulators are covering only a small portion of the retina usually in its center. To restore not only central vision but also a useful visual field retinal stimulators need to cover a larger area of the retina.

View Article and Find Full Text PDF

Background: The purpose of this study was to test the effect of ethyl alcohol on the koniocellular and magnocellular pathway of visual function and to investigate the relationship between such visual field changes and retrobulbar blood flow in healthy subjects.

Methods: In 12 healthy subjects (mean age 32 ± 4 years), color Doppler imaging, short-wavelength automated perimetry, and frequency doubling perimetry was performed before and 60 minutes after oral intake of 80 mL of 40 vol% ethanol. Mean and pattern standard deviations for short-wavelength automated and frequency doubling perimetry were assessed.

View Article and Find Full Text PDF