Background And Purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials. However, clinical implementation of this promising treatment option has been limited because of the lack of availability of accelerators capable of delivering UHDR RT. Commercial options are finally reaching the market that produce electron beams with average dose rates of up to 1000 Gy/s.
View Article and Find Full Text PDFPurpose: This study explores the dosimetric feasibility and plan quality of hybrid ultra-high dose rate (UHDR) electron and conventional dose rate (CDR) photon (HUC) radiotherapy for treating deep-seated tumours with FLASH-RT.
Methods: HUC treatment planning was conducted optimizing a broad UHDR electron beam (between 20-250 MeV) combined with a CDR VMAT for a glioblastoma, a pancreatic cancer, and a prostate cancer case. HUC plans were based on clinical prescription and fractionation schemes and compared against clinically delivered plans.
Background & Purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials. However, clinical implementation of this promising treatment option has been limited because of the lack of availability of accelerators capable of delivering UHDR RT. Commercial options are finally reaching the market that produce electron beams with average dose rates of up to 1000 Gy/s.
View Article and Find Full Text PDFPurpose: Clinical translation of FLASH-radiotherapy (RT) to deep-seated tumours is still a technological challenge. One proposed solution consists of using ultra-high dose rate transmission proton (TP) beams of about 200-250 MeV to irradiate the tumour with the flat entrance of the proton depth-dose profile. This work evaluates the dosimetric performance of very high-energy electron (VHEE)-based RT (50-250 MeV) as a potential alternative to TP-based RT for the clinical transfer of the FLASH effect.
View Article and Find Full Text PDFBackground: Pre-clinical ultra-high dose rate (UHDR) electron irradiations on time scales of 100 ms have demonstrated a remarkable sparing of brain and lung tissues while retaining tumor efficacy when compared to conventional dose rate irradiations. While clinically-used gantries and intensity modulation techniques are too slow to match such time scales, novel very-high energy electron (VHEE, 50-250 MeV) radiotherapy (RT) devices using 3D-conformed broad VHEE beams are designed to deliver UHDR treatments that fulfill these timing requirements.
Purpose: To assess the dosimetric plan quality obtained using VHEE-based 3D-conformal RT (3D-CRT) for treatments of glioblastoma and lung cancer patients and compare the resulting treatment plans to those delivered by standard-of-care intensity modulated photon RT (IMRT) techniques.
Purpose: Compared with conventional dose rate irradiation (CONV), ultrahigh dose rate irradiation (UHDR) has shown superior normal tissue sparing. However, a clinically relevant widening of the therapeutic window by UHDR, termed "FLASH effect," also depends on the tumor toxicity obtained by UHDR. Based on a combined analysis of published literature, the current study examined the hypothesis of tumor isoefficacy for UHDR versus CONV and aimed to identify potential knowledge gaps to inspire future in vivo studies.
View Article and Find Full Text PDFAt the Photo Injector Test facility at DESY in Zeuthen (PITZ), an R&D platform for electron FLASH and very high energy electron radiation therapy and radiation biology is being prepared (FLASHlab@PITZ). The beam parameters available at PITZ are worldwide unique. They are based on experiences from 20 + years of developing high brightness beam sources and an ultra-intensive THz light source demonstrator for ps scale electron bunches with up to 5 nC bunch charge at MHz repetition rate in bunch trains of up to 1 ms length, currently 22 MeV (upgrade to 250 MeV planned).
View Article and Find Full Text PDFBackground And Purpose: We describe a multicenter cross validation of ultra-high dose rate (UHDR) (>= 40 Gy/s) irradiation in order to bring a dosimetric consensus in absorbed dose to water. UHDR refers to dose rates over 100-1000 times those of conventional clinical beams. UHDR irradiations have been a topic of intense investigation as they have been reported to induce the FLASH effect in which normal tissues exhibit reduced toxicity relative to conventional dose rates.
View Article and Find Full Text PDFPurpose: Normal tissue (NT) sparing by ultra-high dose rate (UHDR) irradiations compared to conventional dose rate (CONV) irradiations while being isotoxic to the tumor has been termed "FLASH effect" and has been observed when large doses per fraction (d ≳ 5 Gy) have been delivered. Since hypofractionated treatment schedules are known to increase toxicities of late-reacting tissues compared to normofractionated schedules for many clinical scenarios at CONV dose rates, we developed a formalism based on the biologically effective dose (BED) to assess the minimum magnitude of the FLASH effect needed to compensate the loss of late-reacting NT sparing when reducing the number of fractions compared to a normofractionated CONV treatment schedule while remaining isoeffective to the tumor.
Methods: By requiring the same BED for the tumor, we derived the "break-even NT sparing weighting factor" W for the linear-quadratic (LQ) and LQ-linear (LQ-L) models for an NT region irradiated at a relative dose r (relative to the prescribed dose per fraction d to the tumor).
Int J Radiat Oncol Biol Phys
December 2022
Purpose: The FLASH effect designates normal tissue sparing by ultra-high dose rate (UHDR) compared with conventional dose rate irradiation without compromising tumor control. Understanding the magnitude of this effect and its dependency on dose are essential requirements for an optimized clinical translation of FLASH radiation therapy. In this context, we evaluated available experimental data on the magnitudes of normal tissue sparing provided by the FLASH effect as a function of dose, and followed a phenomenological data-driven approach for its parameterization.
View Article and Find Full Text PDFPurpose: The Oriatron eRT6 is a linear accelerator (linac) used in FLASH preclinical studies able to reach dose rates ranging from conventional (CONV) up to ultrahigh (UHDR). This work describes the implementation of commercially available beam current transformers (BCTs) as online monitoring tools compatible with CONV and UHDR irradiations for preclinical FLASH studies.
Methods: Two BCTs were used to measure the output of the Oriatron eRT6 linac.
A patient with a cutaneous lymphoma was treated on the same day for 2 distinct tumors using a 15 Gy single electron dose given in a dose rate of 0.08 Gy/second versus 166 Gy/second. Comparing the two treatments, there was no difference for acute reactions, late effects at 2 years and tumor control.
View Article and Find Full Text PDFPurpose: To derive the isodose line R relative to the prescription dose below which irradiated normal tissue (NT) regions benefit from a hypofractionated schedule with an isoeffective dose to the tumor. To apply the formalism to clinical case examples.
Methods: From the standard biologically effective dose (BED) equation based on the linear-quadratic (LQ) model, the BED of an NT that receives a relative proportion r of the prescribed dose per fraction for a given α/β-ratio of the tumor, (α/β) , and NT, (α/β) , is derived for different treatment schedules while keeping the BED to the tumor constant.
Purpose: To implement and validate a beam current transformer as a passive monitoring device on a pulsed electron beam medical linear accelerator (LINAC) for ultra-high dose rate (UHDR) irradiations in the operational range of at least 3 Gy to improve dosimetric procedures currently in use for FLASH radiotherapy (FLASH-RT) studies.
Methods: Two beam current transformers (BCTs) were placed at the exit of a medical LINAC capable of UHDR irradiations. The BCTs were validated as monitoring devices by verifying beam parameters consistency between nominal values and measured values, determining the relationship between the charge measured and the absorbed dose, and checking the short- and long-term stability of the charge-absorbed dose ratio.
Purpose: Driven by advances in accelerator technology and the potential of exploiting the FLASH effect for the treatment of deep-seated targets (>5 cm), there is an active interest in the construction of devices to deliver very high-energy electron (VHEE) beams for radiation therapy. The application of novel VHEE devices, however, requires an assessment of the tradeoffs between the different beam parameter choices including beam energies, beam divergences, and maximal field sizes. This study systematically examines the dosimetric beam properties of VHEE beams, determining their clinical usefulness while marking their limits of applications for different beam configurations.
View Article and Find Full Text PDFPurpose: To present the acceptance and the commissioning, to define the reference dose, and to prepare the reference data for a quality assessment (QA) program of an ultra-high dose rate (UHDR) electron device in order to validate it for preclinical animal FLASH radiotherapy (FLASH RT) experiments and for FLASH RT clinical human protocols.
Methods: The Mobetron device was evaluated with electron beams of 9 MeV in conventional (CONV) mode and of 6 and 9 MeV in UHDR mode (nominal energy). The acceptance was performed according to the acceptance protocol of the company.
Purpose: Recent data have shown that single-fraction irradiation delivered to the whole brain in less than tenths of a second using FLASH radiotherapy (FLASH-RT), does not elicit neurocognitive deficits in mice. This observation has important clinical implications for the management of invasive and treatment-resistant brain tumors that involves relatively large irradiation volumes with high cytotoxic doses.
Experimental Design: Therefore, we aimed at simultaneously investigating the antitumor efficacy and neuroprotective benefits of FLASH-RT 1-month after exposure, using a well-characterized murine orthotopic glioblastoma model.
Purpose: To investigate the impact of respiratory motion in the treatment margins for lung SBRT frameless treatments and to validate our treatment margins using 4D CBCT data analysis.
Methods: Two hundred and twenty nine fractions with early stage NSCLC were retrospectively analyzed. All patients were treated in frameless and free breathing conditions.
Purpose: The purpose of this study was to calculate dose distributions from CyberKnife image-guided radiation therapy (IGRT) for brain, H&N, lung, and pelvis treatment regions and use them to extract the corresponding effective dose and estimate-related risk.
Methods: We developed a CyberKnife IGRT kV beam model in a standard treatment planning system and validated it against measurements in heterogeneous phantoms. Five brain, five head and neck, five thorax, and 10 (five male and five female) pelvis patient computed tomographies (CTs) were contoured.
Background: When compared to conventional radiotherapy (RT) in pre-clinical studies, FLASH-RT was shown to reproducibly spare normal tissues, while preserving the anti-tumor activity. This marked increase of the differential effect between normal tissues and tumors prompted its clinical translation. In this context, we present here the treatment of a first patient with FLASH-RT.
View Article and Find Full Text PDFOver the past decades, technological advances have transformed radiation therapy (RT) into a precise and powerful treatment for cancer patients. Nevertheless, the treatment of radiation-resistant tumors is still restricted by the dose-limiting normal tissue complications. In this context, FLASH-RT is emerging in the field.
View Article and Find Full Text PDFPurpose: Preclinical studies using a new treatment modality called FLASH Radiotherapy (FLASH-RT) need a two-phase procedure to ensure minimal uncertainties in the delivered dose. The first phase requires a new investigation of the reference dosimetry lying outside the conventional metrology framework from national metrology institutes but necessary to obtain traceability, repeatability, and stability of irradiations. The second consists of performing special quality assurance procedure prior to irradiation.
View Article and Find Full Text PDF