Obsessive-Compulsive Disorder (OCD) is characterized by intrusive thoughts and repetitive behaviors, with associated brain abnormalities in various regions. This study explores the correlation between neural biomarkers and the response to transcranial Direct Current Stimulation (tDCS) in OCD patients. Using structural MRI data from two tDCS trials involving 55 OCD patients and 28 controls, cortical thickness, and gray matter morphometry was analyzed.
View Article and Find Full Text PDFThe existing body of literature on the biomechanical implications of ramp lesions is limited, leaving a significant gap in our understanding of how these lesions impact joint kinematics and loading in the medial compartment. This cadaveric biomechanical study aims to address this gap by employing an innovative Digital Volume Correlation (DVC) method, utilizing 7 Tesla Magnetic Resonance Imaging (MRI) images under various loading conditions. The primary objective is to conduct a comprehensive comparison of medial meniscal mobility between native knees and knees affected by grade 4 ramp lesions.
View Article and Find Full Text PDFLumbar disc arthroplasty is a surgical procedure designed to treat degenerative disc disease by replacing the affected disc with a mobile prosthesis. Several types of implants fall under the term total disc replacement, such as ball-and-socket, mobile core or elastic prostheses. Some studies have shown that facet arthritis can develop after arthroplasty, without much precision on the mechanical impact of the different implant technologies on the facet joints.
View Article and Find Full Text PDFThe aim of treatments of vertebral fractures is the anatomical reduction to restore the physiological biomechanics of the spine and the stabilization of the fracture to allow bone healing. However, the three-dimensional shape of the fractured vertebral body before the fracture is unknown in the clinical setting. Information about the pre-fracture vertebral body shape could help surgeons to select the optimal treatment.
View Article and Find Full Text PDFIntroduction: Fractures of the calcaneus are common, with 65% being intra-articular, which can lead to a major impairment of the patient's quality of life. Open reduction and internal fixation with locking plates can be considered as gold-standard technique but has a high rate of post-operative complications. Minimally invasive calcaneoplasty combined with minimally invasive screw osteosynthesis is largely drawn from the management of depressed lumbar or tibial plateau fractures.
View Article and Find Full Text PDFIntroduction: Spinal fractures with a split component present specific bone union problems (pseudarthrosis). The purpose of this study was to assess the rate of pseudarthrosis after stand-alone percutaneous kyphoplasties and analyze clinical and radiographic parameters that are predictive of its efficacy in thoracolumbar spine fractures with a split-type of injury.
Hypothesis: Stand-alone kyphoplasty results in satisfactory bone union of the treated vertebral body despite the diastasis of fracture fragments.
Purpose: Although the mechanisms of injury are similar to ACL rupture in adults, publications dealing with meniscal lesions resulting from fractures of the intercondylar eminence in children are much rarer. The main objective was to measure the frequency of meniscal lesions associated with tibial eminence fractures in children. The second question was to determine whether there is any available evidence on association between meniscal tears diagnostic method, and frequencies of total lesions, total meniscal lesions, and total entrapments.
View Article and Find Full Text PDFPurpose: The objective of this study was to analyze the intra- and interobserver variability of this measurement according to a strict methodology and on a representative sample of the general population, as well as to identify the possible difficulties of measurement in case of patellar or trochlear dysplasia.
Methods: This observational study involved radiographic analysis by three independent observers of a total of 50 patients who had a loaded patellofemoral X-ray taken with the knee flexed to 45°. An initial reading was taken to measure the angle of the trochlear sulcus, the Merchant angle, and to classify the knees according to a possible trochlear dysplasia and/or patellar dysplasia according to Wiberg.
Introduction: The objective of this study was to compare the rates of radiological and clinical complications after sequential treatment of a tibial shaft fracture by external fixation followed by secondary nailing with an early-stage conversion (C1S) versus a two-stage late conversion (C2S). The hypothesis of this work was that treatment with C1S does not increase the risk of surgical site infections compared to C2S, and allows faster healing with a lower malunion rate.
Material And Methods: We carried out a retrospective and comparative study based on the files of the traumatology department of the Édouard Herriot University Hospital in Lyon.
To date, no study has described the microbiological profile of surgical site infections (SSIs) after spine surgery in a tropical environment. The main objective of this study is to describe the microbiology and the risk factors of SSI after spinal surgery in a tropical climate. Our hypothesis is that the microbiology of SSIs in tropical areas is different to what is mainly described in temperate countries.
View Article and Find Full Text PDFThe development of new percutaneous treatment techniques using a balloon for the reduction and cement for the stabilization for tibial plateau fractures (TPF) are promising. The biomechanical changes brought by the cement in the periarticular fracture are unknown. The objective of this study was to provide elements of understanding of the bone behavior in an epiphyseal fracture treated with cementoplasty and to define the modifications brought about by the presence of this cement in the bone from both an architectural and biomechanical point of view.
View Article and Find Full Text PDFTibial plateau fracture is a frequent entity for which surgical management is difficult both surgically and postoperatively, with multiple complications and often delayed recovery. The challenge lies in the anatomical reduction of the joint, the limitation of complications and the rapid functional recovery. Tuberoplasty appears to be an innovative technique that meets current expectations.
View Article and Find Full Text PDFIntroduction: The understanding of the stresses and strains and their dependence on loading direction caused by an axial deformity is very important for understanding the mechanism of femural neck fractures. The hypothesis of this study is that lower limb malalignment is correlated with a substantial stress variation on the upper end of the femur. The purpose of this biomechanical trial using the finite element method is to determine the effect of the loading direction on the proximal femur regarding the malalignment of the lower limb, and also enlighten the relation between the lower limb alignment and the risk of a femoral neck fracture.
View Article and Find Full Text PDFThe most common type of fracture of the lateral tibial plateau is the Schatzker type II split-depressed fracture. Minimally invasive surgery using balloon reduction appears to be very promising compared to the gold standard using a bone tamp. This surgery aims to have the best reduction and stabilization to benefit from an early passive and active rehabilitation to avoid stiffening and muscle wasting.
View Article and Find Full Text PDFBackground: Atypical femoral fractures (AFF) are diaphyseal fractures of the elderly that occur at the end of a minor trauma. The objective of this biomechanical study, using finite element modelling, was to evaluate the variations of the femoral diaphysis fracture indicator according to the variations of the mechanical axis of the lower limb, which can explain all the different atypical fracture types identified in the literature.
Methods: In order to measure variations in stress and risk factors for fracture of the femoral diaphysis, the distal end of the femur was constrained in all degrees of freedom.
Surgical procedures are evolving toward less invasive and more tailored approaches to consider the specific pathology, morphology, and life habits of a patient. However, these new surgical methods require thorough preoperative planning and an advanced understanding of biomechanical behaviors. In this sense, patient-specific modeling is developing in the form of digital twins to help personalized clinical decision-making.
View Article and Find Full Text PDFMinimally invasive methods, such as balloon kyphoplasty (BKP) and percutaneous sacroplasty (PS), which are now widely used for the surgical treatment of compression fractures, involve injection of a bolus of poly (methyl methacrylate) bone cement (hereafter, "bone cement") into the fractured tissue. Many of the common complications following these surgeries, such as cement leakage and adjacent-level fractures (in the case of BKP), have been postulated to be related to the quality of the cancellous bone-bone cement interface, which, in turn, is a function of its fracture resistance. It is common to use bovine cancellous bone or polyurethane foam (PF) as a substitute for human cancellous bone in biomechanical studies of these surgical methods.
View Article and Find Full Text PDFLow back pain is a dramatic burden worldwide. Discography studies have shown that 39% of chronic low back pain patients suffer from discogenic pain due to a radial fissure of intervertebral disc. This can have major implications in clinical therapeutic choices.
View Article and Find Full Text PDFObjective: To compare radiologically balloon kyphoplasty (BKP) and vertebral compression fracture (VCF) expansion and corroborate with a finite element (FE) analysis. The principle of BKP is to stabilize VCF by restoring vertebral body anatomy using bone expansion and cement filling. More recently, vertebral body stenting (VBS) has been developed to reduce the loss of vertebral height observed after balloon deflation.
View Article and Find Full Text PDFBackground: Occipito-cervical fusion can be necessary in case of cranio-cervical junction instability. Proximal stabilisation is usually ensured by bi-cortical occipital screws implanted through one median or two lateral occipital plate(s). Bone thickness variability as well as the proximity of vasculo-nervous elements can induce substantial morbidity.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
February 2020
The fracture mechanics (FM) parameters of cancellous bone tissues are very important from a clinical point of view especially for the bone cement augmentation. From the literature review, one can observe that the experimental determination of fracture mechanic parameters of cancellous bone are still lacking. This can be due to the conditions associated with the unstable crack propagation in the cancellous bone and lack of tools to extract and measure the parameters (like crack opening displacement (COD) and crack length) in the course of fracture tests, which are necessary to evaluate the fracture properties.
View Article and Find Full Text PDFIntroduction: Fractures of the tibial plateau are in constant progression. They affect an elderly population suffering from a number of comorbidities, but also a young population increasingly practicing high-risk sports. The conventional open surgical technique used for tibial plateau fractures has several pitfalls: bone and skin devascularisation, increased risks of infection and functional rehabilitation difficulties.
View Article and Find Full Text PDFBackground: Schatzker type II tibial plateau fractures necessitate the least invasive treatment possible. Arthroscopic reduction by bone tamp followed by osteosynthesis is the current gold standard for this type of tibial plateau fracture. The objective of this study was to compare this technique to anterior approach tuberoplasty with balloon reduction.
View Article and Find Full Text PDFBackground: Treatment for fractures of the tibial plateau is in most cases carried out by stable fixation in order to allow early mobilization. Minimally invasive technologies such as tibioplasty or stabilization by locking plate, bone augmentation and cement filling (CF) have recently been used to treat this type of fracture. The aim of this paper was to determine the mechanical behavior of the tibial plateau by numerically modeling and by quantifying the mechanical effects on the tibia mechanical properties from injury healing.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
October 2017