Background: Criteria such as electrograms voltage or late potentials have been largely utilized in the past to help identify areas of substrate maps that are within the ventricular tachycardia (VT) isthmus; yet their specificity and positive predictive value are quite low. The Lumipoint fractionation tool of the Rhythmia system illuminates regions with fractionated electrograms irrespective of their timing and annotation. We aimed to ascertain whether the use of this tool can rapidly identify areas within VT isthmuses from substrate maps.
View Article and Find Full Text PDFBackground: Contact force (CF)-sensing catheters have not proved superior to standard catheters in the ablation of premature ventricular contractions (PVCs) from the right and left ventricular outflow tract (RVOT, LVOT). In this context, the utility of measuring local impedance (LI) is not known. We aimed to ascertain whether the use of a catheter combining LI and CF information was associated with superior outcomes in comparison with other catheter technologies.
View Article and Find Full Text PDFBackground: The very high-power short-duration (vHPSD) temperature-controlled ablation (vHPSD) improves the efficiency of pulmonary vein isolation (PVI) procedures. We evaluated the procedural and 12-months outcomes in atrial fibrillation (AF) patients undergoing PVI by means of vHPSD ablation. In patients with AF or atrial tachyarrythmia (AT) recurrence undergoing a redo procedure the durability of the PVI was investigated.
View Article and Find Full Text PDFBackground: Local impedance (LI) drop predicts acute conduction block during pulmonary vein isolation (PVI). Whether the LI drop predicts also the achievement of left atrial posterior wall isolation (LAPWI) in persistent atrial fibrillation (PersAF) patients is unknown. We evaluated the efficacy and the safety of LI drop-guided LAPW ablation by using high power (50 watts) and investigated the impact of ablation parameters on the LI drop.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
July 2022
Introduction: A new dielectric-based method (KODEX-EPD mapping system, EPD Solutions, a Philips company) for measuring tissue thickness at the catheter-tissue interface has recently been developed. We reported preliminarydata on real-time catheter-based measuring myocardial wall thickness in vivo, during typical atrial flutter radio frequency ablation.
Methods And Results: The study population consisted of 12 consecutive patients, suffering from symptomatic paroxysmal or persistent cavo-tricuspid isthmus dependent, counter clockwise and clockwise AFL, under going a first catheter ablation between April 2021 and November 2021.
J Cardiovasc Electrophysiol
July 2022
Introduction: Low-voltage activity beyond pulmonary veins (PVs) may contribute to the failure of ablation of atrial fibrillation (AF) in the long term. We aimed to assess the presence of gaps (PVG) and residual potential (residual antral potential [RAP]) within the antral scar by means of an ultra-high-density mapping (UHDM) system.
Methods: We studied consecutive patients from the CHARISMA registry who were undergoing AF ablation and had complete characterization of residual PV antral activity.
Background: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. We evaluated the feasibility, efficacy and safety of the vHPSD ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL).
Methods: This prospective non-randomized study enrolled 28 consecutive patients (FAST Group) with typical AFL undergoing CTI ablation.
Introduction: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. This study aimed to clarify the contribution of contact force (CF) and temperature and their interrelationship in making an adequate lesion with the vHPSD catheter.
Methods: We enrolled 46 consecutive patients undergoing first catheter ablation for atrial fibrillation (AF).
Pulmonary vein (PV) isolation using cryoballoon (CB) catheter is generally characterized by a high radiation and contrast media exposure. A new dielectric imaging system (KODEX-EPD imaging system) allows pulmonary vein (PV) occlusion assessment without dye use. The purpose of this study was to verify the feasibility of reducing the radiation and dye use during CB ablation in patients with atrial fibrillation (AF) using the new dielectric imaging system.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
September 2020
Introduction: Recently, a novel technology able to measure local impedance (LI) and tissue characteristics has been made available for clinical use. This analysis explores the relationships among LI and generator impedance (GI) parameters in atrial fibrillation (AF) patients. Characterization of LI among different ablation spots and procedural success were also evaluated.
View Article and Find Full Text PDFBackground: Cardiac resynchronization therapy (CRT) is an established treatment in patients with heart failure and prolonged QRS duration. A biventricular device is implanted to achieve faster activation and more synchronous contraction of the ventricles. Despite the convincing effect of CRT, 30-40% of patients do not respond.
View Article and Find Full Text PDFWe report a first case of a highly complicated lead extraction in a young man who previously underwent orthotopic heart transplantation (OHT).Lead extraction in transplanted patients may be a feasible and safe procedure in order to maintain a low infective risk and to preserve alternative vascular access sites.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
January 2019
Purpose: Reconnection of pulmonary veins (PVs) remains common following radiofrequency catheter ablation for atrial fibrillation (AF). Ablation Index (AI) is a novel ablation quality marker that incorporates stability, contact force (CF), time, and power in a weighted formula. Its use seems to improve lesion durability.
View Article and Find Full Text PDFThe creation of a durable radiofrequency (RF) lesion depends on several parameters, including catheter tip electrode size and composition, tip orientation, temperature, RF pulse duration, power, blood flow, and catheter to tissue contact. The development of new contact force (CF) sensor catheters has allowed the measurement of the tip to tissue CF during the RF ablation procedure. Here, we describe the clinical experience obtained using CF catheters for atrial fibrillation ablation, with a specific focus on the impact of CF technology on acute procedural data (procedure and fluoroscopy time).
View Article and Find Full Text PDFPacing Clin Electrophysiol
March 2009
Objective: To compare the rates of all-cause mortality in recipients of cardiac resynchronization therapy devices without (CRT-PM) versus with defibrillator (CRT-D).
Methods: Between February 1999 and July 2004, 233 patients (mean age = 69 +/- 8 years, 180 men) underwent implantation of CRT-PM or CRT-D devices. New York Heart Association (NYHA) heart failure functional class II was present in 11%, class III in 69%, and class IV in 20% of patients; mean left ventricle ejection fraction (LVEF) was 26.
Pacing Clin Electrophysiol
January 2007
Background: Little is known regarding the long-term performance of coronary sinus (CS) leads, which have an effect on the longevity of cardiac resynchronization therapy (CRT) systems.
Methods: This study included 109 patients (79 men) whose mean age was 68 +/- 9 years, New York Heart Association (NYHA) functional class 3.2 +/- 0.