Background: Homogeneous intraocular lens (IOL) calcification deteriorates patient's visual quality. There is a lack of functional and patient-reported data on patients with this material change undergoing IOL exchange surgery. The aim of this study was to evaluate subjective and objective outcomes following IOL exchange due to homogeneous IOL calcification to improve evidence-based patient counseling.
View Article and Find Full Text PDFIntroduction: To evaluate the anterior chamber (AC) inflammation in the early postoperative period after cataract surgery and before Descemet membrane endothelial keratoplasty (DMEK) by quantifying oxidative stress and inflammatory mediators in aqueous humor of patients with Fuchs' endothelial corneal dystrophy (FECD).
Methods: In this prospective single-center study, 15 patients with FECD underwent cataract surgery and DMEK in a two-stage procedure. Aqueous humor was collected from the AC at the beginning of cataract surgery and 3 months later at the beginning of DMEK.
This study presents a systematic method to simulate various intraocular lenses (IOLs) available in the market. Five IOLs (two trifocals, one bifocal, one enhanced monofocal, and one extended depth of focus (EDOF)) were evaluated in terms of through focus visual Strehl (TFVS) utilizing the OptiSpheric IOL PRO2 device (Trioptics GmbH). Then, the estimated TFVS (ETFVS) and the temporal coefficients necessary for temporal multiplexing were computed, and through an iterative process, the SimVis TFVS was obtained.
View Article and Find Full Text PDFGraefes Arch Clin Exp Ophthalmol
November 2024
Purpose: To assess visual outcomes and stability of lens alignment more than 3 years after implanting either the AT Lisa Tri Toric (Carl Zeiss Meditec) or the Acrysof IQ Restor Toric (Alcon Laboratories, Inc) intraocular lens (IOL).
Methods: Patients who had received either the AT Lisa Tri Toric or the Acrysof IQ Restor Toric IOL were included in the study. The average follow-up period was 5.
Purpose: In October 2023, other cases with early silicone oil opacification within hours after intraocular implantation in the absence of emulsification occurred. While multiple, small series of this phenomenon are now documented during the last decade, the cause was never unmasked. In this study, we analyzed explanted patient samples, unused samples of the affected, and a control batch of the same silicone oil.
View Article and Find Full Text PDFPurpose: The purpose of this study was to report the safety and efficacy results of an artificial lamellar implant for the treatment of chronic corneal edema.
Methods: The EndoArt (EyeYon Medical, Ness Ziona, Israel), an artificial endothelial replacement membrane designed to treat corneal edema, was implanted in 24 eyes of 24 patients with low-to-normal visual potential. We present the safety and efficacy results from a prospective, open-label, single-arm, multicenter study conducted over a 12-month period.
Purpose: AT ELANA is a recently introduced trifocal intraocular lens (IOL) made of a hydrophobic material. The new IOL's optical function was examined against an equivalent version made of hydrophilic material. .
View Article and Find Full Text PDFCurr Opin Ophthalmol
January 2025
Purpose Of Review: This review summarizes the evidence on the effect of intraocular lens (IOL) material on the outcomes of cataract surgery, as well as on the surgical procedure itself.
Recent Findings: Differences in capsular biocompatibility between IOL materials lead to variations in capsular stability and posterior capsule opacification (PCO), while differences in uveal biocompatibility affect postoperative inflammatory response.
Summary: Refractive outcomes are affected by both incision size and the rotational stability of toric IOLs.
Vitreous floaters are visual phenomena resulting from floating opacities inside the eye that disturb vision. The opacities consist of microscopic collagen fibers that aggregate in myopia and during aging. These collagen fibers are then seen as irregular, sometimes worm-like shadows or structures of a translucent to black color.
View Article and Find Full Text PDFThis study aimed to determine the through-focus performance and the effect of misalignment on the optical quality of different aspheric monofocal intraocular lenses (IOLs). To this end, optical quality was assessed in three IOL models with different optic surfaces: standard aberration neutral model and two spherical aberration (SA) correcting, one of which utilizes higher-order aspheric terms. The optical quality was measured by means of the modulation transfer function at 3- and 4.
View Article and Find Full Text PDFBackground: Small Descemet membrane detachments after cataract surgery are relatively common and most cases do not require any secondary surgical intervention and can be treated conservatively. However, in case of advanced Descemet membrane detachment (DMD), it needs to be recognized and treated appropriately. The advent of anterior segment imaging using optical coherence tomography (OCT) technology has made diagnosing pathologies of the anterior segment accurate and time efficient and has proven as an invaluable tool to guide decision making.
View Article and Find Full Text PDFGraefes Arch Clin Exp Ophthalmol
September 2024
Polypseudophakia, the concept of using a second intraocular lens (IOL) to supplement an IOL that has already been placed in the capsular bag, was first used as a corrective measure where the power requirement was higher than that of available single IOLs. Subsequently, the technique was modified to compensate for post-operative residual refractive errors. In these early cases, an IOL designed for the capsular bag would be implanted in the sulcus.
View Article and Find Full Text PDFAnti-VEGF agents, e.g., bevacizumab, are used in retinal surgery, while their interaction with silicone oils and novel hydrogels remains unclear.
View Article and Find Full Text PDFA variety of situations can lead to the need for an alternative method of intraocular lens (IOL) fixation if implantation in the capsular bag is not possible. Depending on the situation, sulcus-fixated IOLs, iris-fixated IOLs (IFIOLs) and scleral-fixated IOLs (SFIOLs) are available. With SFIOLs, a distinction is made between suture-fixated and sutureless-fixated techniques.
View Article and Find Full Text PDFPurpose: We investigated the vertical implantation of a toric implantable collamer lens (ICL) and compared the rotational stability with that of horizontal implantation.
Methods: This matched comparative study retrospectively reviewed and analyzed data from patients who underwent ICL implantation from 2003-2022 by 1:1 matching vertical and horizontal (V and H toric groups, respectively) implantation patients according to preoperative astigmatism, spherical equivalent, sulcus-to-sulcus, anterior chamber depth, and ICL size. Visual acuity, manifest refraction, vaulting, and rotation were measured 3 months postoperatively.
Intravitreal injections (IVI s) have gained increased popularity in the past decades and are used to treat a multitude of ailments. In 2010, the total number of IVI s surpassed the number of cataract surgeries performed, making it the most common procedure in ophthalmology. As the number of injections increases, so does the number of injected-related complications.
View Article and Find Full Text PDFIn modern ophthalmic surgery, an intraocular lens (IOL) is commonly implanted into the patient's eye with an IOL injector. Many injectors are available, showing various technological differences, from the early manually loaded injector systems to the modern preloaded injectors. This review aims to give a concise overview of the defining characteristics of injector models and draws attention to complications that may occur during IOL implantation.
View Article and Find Full Text PDF