Publications by authors named "Gerardo Nigro"

The historical restriction of magnetic resonance imaging (MRI) for patients with cardiac implantable electronic devices (CIEDs) has been lifted by certified MRI-conditional systems in recent years. Mixed-brand CIED systems consisting of a generator from one manufacturer and at least one lead from another manufacturer are not certified for MRI. We evaluated the temporal trend in the prevalence of mixed-brand systems in the era of MRI-conditional systems.

View Article and Find Full Text PDF

Background: Neurally mediated reflex syncope (NMRS) has been recently described as a possible trigger of Takotsubo syndrome (TTS). There are few data in the literature about this association.

Methods: In the present meta-summary, 6 case reports describing patients who experienced TTS following an NMRS episode were included.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess how common vasodepressor (VD) responses are during head-up tilt tests (HUTT) in patients with a history of fainting (syncope) over a six-year period.
  • Out of 1,780 patients, 7% exhibited a VD response, with higher rates observed in males and those over 69 years old.
  • Age was found to be the only significant predictor of VD response, while factors like smoking and atypical fainting presentations reduced the likelihood of this response.
View Article and Find Full Text PDF

Aims: The study evaluated the positivity rate, haemodynamic responses, and prognosis in terms of syncopal recurrence among patients with situational syncope (SS) stratified according to the underlying situational triggers.

Methods And Results: We retrospectively evaluated all consecutive patients with SS who underwent nitroglycerine (NTG)-potentiated head-up tilt test (HUTT) at Syncope Unit of the University of Campania 'Luigi Vanvitelli'-Monaldi Hospital from 1 March 2017 to 1 May 2023. All patients were followed for at least one year.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated the prevalence of out-of-range plasma levels of direct oral anticoagulants (DOACs) in patients with atrial fibrillation (AF) who underwent elective cardiac procedures, focusing on proper timing of DOAC withdrawal.
  • Out of 90 AF patients evaluated, 82.22% had DOAC concentrations outside expected ranges; about 41% had levels below the trough, which is the minimum effective concentration of the drug.
  • Key predictors for low DOAC levels included inappropriate withdrawal periods and increased kidney function (creatinine clearance), while diabetes was linked to higher DOAC levels above the trough range.
View Article and Find Full Text PDF

Background: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE.

Objective: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence.

View Article and Find Full Text PDF

Background: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking.

View Article and Find Full Text PDF
Article Synopsis
  • - The study examines patients with unexplained syncope and negative head-up tilt tests (HUTT), finding that about 50% have asystolic pauses during spontaneous syncope events recorded by implantable loop recorders (ILR).
  • - A total of 113 patients were analyzed, revealing that 28 showed asystolic syncope during monitoring, mostly categorized as type 1A; the age distribution for asystolic syncope was bimodal, with peaks in those under 19 and those aged 60-79.
  • - The research concluded that the absence of warning signs before syncope (prodromes) and the use of beta blockers were significant predictors of asystolic events detected by ILR, indicating
View Article and Find Full Text PDF

Background: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG).

Objective: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG.

Methods: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG.

View Article and Find Full Text PDF

Background: Remote monitoring is recommended for patients with implantable cardiac monitors (ICMs), but compared to other cardiac implantable devices, ICMs are less accurate and transmit a higher number of alerts.

Objective: The aim of this study was to investigate the predictors of false-positive (FP) arrhythmic alerts in patients with unexplained syncope who were implanted with ICM and followed by an automatic remote monitoring system.

Methods: We retrospectively evaluated all consecutive patients who received a long-sensing vector ICM for unexplained syncope between January 2019 to September 2021 at our Syncope Unit.

View Article and Find Full Text PDF

Background: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P.

Methods: Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P.

View Article and Find Full Text PDF

Aims: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation.

View Article and Find Full Text PDF

Objective: The study compared clinical characteristics and response at head-up tilt test (HUTT) between situational (SS) and vasovagal syncope (VVS).

Methods: Consecutive patients who underwent nitroglycerin-potentiated HUTT were retrospectively dichotomised into two groups: those with a history of SS and those with a history of VVS. The patients with SS were further subdivided into patients with SS alone and with SS and at least one episode of VVS.

View Article and Find Full Text PDF

Sodium-glucose cotransporter 2 inhibitors (SGLT2-i) are a novel class of oral hypoglycemic agents currently used among patients with type 2 diabetes mellitus (T2DM). The effects of SGLT2-i inhibitors on cardiac structure and function are not fully understood. The aim of this study is to evaluate the echocardiographic changing among patients with well-controlled T2DM treated with SGLT2-i in real-world setting.

View Article and Find Full Text PDF

Background: There are little data on remote monitoring (RM) of implantable loop recorders (ILRs) in patients with unexplained syncope and whether it confers enhanced diagnostic power.

Objective: To evaluate the effect of RM in ILR recipients for unexplained syncope for early detection of clinically relevant arrhythmias by comparison with a historical cohort with no RM.

Methods: SyncRM is a propensity score (PS)-matched study prospectively including 133 consecutive patients with unexplained syncope and ILR followed up by RM (RM-ON group).

View Article and Find Full Text PDF

Aims: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice.

View Article and Find Full Text PDF

Background: The traditional nitroglycerin (NTG) head-up tilt test (HUTT) is time-consuming and the test duration is a barrier to widespread utilization in clinical practice. It was hypothesized that a short-duration protocol is not inferior to the traditional protocol regarding the positivity rate and has a similar distribution of hemodynamic response.

Methods And Results: Patients undergoing HUTT were randomized 1:1 to a 10 min passive phase plus a 10 min 0.

View Article and Find Full Text PDF

Thromboembolic events (TEE) associated with atrial fibrillation (AF) are highly recurrent and usually severe, causing permanent disability or, even, death. Previous data consistently showed significantly lower TEE in anticoagulated patients. While warfarin, a vitamin K antagonist, is still used worldwide, direct-acting oral anticoagulants (DOACs) have shown noninferiority to warfarin in the prevention of TEE, and represent, to date, the preferred treatment.

View Article and Find Full Text PDF

Aims: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies.

Methods And Results: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres.

View Article and Find Full Text PDF

Background: Conduction system pacing (CSP) using His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has emerged as an alternative to right ventricular pacing (RVP). Comparative data on the risk of complications between CSP and RVP are lacking.

Objective: This prospective, multicenter, observational study aimed to compare the long-term risk of device-related complications between CSP and RVP.

View Article and Find Full Text PDF