Aims: To compare 5-year angiographic, optical coherence tomography (OCT), and clinical outcomes between patients treated with bioresorbable vascular scaffolds (BVS) and drug-eluting stents (DES).
Methods: The EverBio-2 trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) was a single-center, assessor-blinded, randomized controlled trial in which 240 patients were randomly allocated (1:1:1) to BVS, everolimus-eluting (EES) or biolimus-eluting (BES) DES. Clinical follow-up was scheduled up to 5 years.
Aims: To compare endothelium-dependent vasomotor function and vascular healing 15 months after implantation of two new-generation drug-eluting stents and biovascular scaffolds (BVS).
Methods And Results: A total of 28 patients previously treated with a SYNERGY stent (bioabsorbable polymer everolimus-eluting stents (BP-EES)), a PROMUS stent (persistent polymer everolimus-eluting stents (PP-EES)) or an ABSORB (BVS) underwent control coronary angiography, 15 months after implantation, coupled with optical coherence tomography imaging and supine bicycle exercise. Intracoronary nitroglycerin was administered after exercise testing.
Background: Data from randomized controlled trials have shown that the ABSORB BVS is non-inferior to Cobalt Chromium everolimus-eluting stents at 2years.
Methods & Results: The EVERBIO II trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) is a single-center, assessor-blind, randomized controlled trial enrolling 240 patients with an allocation ration of 1:1:1 conducted at University and Hospital Fribourg, Switzerland. The studied devices were an everolimus-eluting persistent polymer stent (EES), a biolimus-eluting stent with bioabsorbable polymer (BES) and a fully bioresorbable vascular scaffold (BVS).
This investigation sought to determine the feasibility of a novel mitral ring designed to reshape mitral annulus on beating heart, after surgery. The mitral ring is intended to improve mitral leaflets coaptation to correct residual and recurrent mitral regurgitations. It could also provide progressive correction of mitral regurgitation.
View Article and Find Full Text PDFWe sought to compare operator radiation exposure during procedures using right femoral access (RFA), right radial access (RRA), and left radial access (LRA) during coronary angiography (CA) and percutaneous coronary intervention (PCI). Because of an increased incidence of long-term malignancy in interventional cardiologists, operator radiation exposure is of rising concern. This prospective study included all consecutive patients who underwent elective or emergency CA ± PCI from September 2014 to March 2015.
View Article and Find Full Text PDFQuestions Under Study: Head-to-head optical coherence tomography (OCT) data comparing metallic stents with bioresorbable vascular scaffolds (BVS) are lacking. This study assessed vascular healing at 9-month follow-up after implantation of everolimus- and biolimus-eluting stents (EES; BES) and everolimus-eluting BVS.
Methods: OCT was performed in 74 patients enrolled in the EVERBIO II (NCT01711931) trial (23 with EES: 26 lesions, 7 625 struts; 23 with BES: 26 lesions, 6 140 struts; 28 with BVS: 33 lesions, 10 891 struts).
Int J Cardiol
January 2016
Background: Drug-eluting stents (DES) have been associated with local endothelial dysfunction in the segments proximal and distal to the stent (peristent segments) and increased thrombotic risk in long term follow-up. Little data exists on endothelial function post-implantation of new DES with biodegradable polymer. The aim of our study was to compare the local endothelial function assessed by exercise induced coronary vasomotion after implantation of a biolimus A9-eluting stent with biodegradable polymer (BES) with an everolimus-eluting stent with durable polymer (EES).
View Article and Find Full Text PDFBackground: The first CE-approved bioresorbable vascular scaffold (BVS) is effective at treating simple lesions and stable coronary artery disease, but it has yet to be assessed versus the best-in-class drug-eluting stents (DES).
Objectives: This study sought to compare the performance of a BVS with that of everolimus-eluting stents (EES) and biolimus-eluting stents (BES) in all-comer patients.
Methods: The EVERBIO II (Comparison of Everolimus- and Biolimus-Eluting Stents With Everolimus-Eluting Bioresorbable Vascular Scaffold Stents II) trial was a single-center, assessor-blinded study of 240 patients randomly assigned in a 1:1:1 ratio to EES, BES, or BVS.
Background: Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates.
View Article and Find Full Text PDFQuestions Under Study: Diagnosis of acute kidney injury (AKI) relies on measurement of serum creatinine (SCr). SCr is a late marker of impaired renal function. Urinary Neutrophil Gelatinase-Associated Lipocalin (uNGAL) has given encouraging results for an early and sensitive detection of AKI.
View Article and Find Full Text PDFAims: Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES.
View Article and Find Full Text PDFBackground: The salt linked to the clopidogrel molecule in generic preparations is suspected to affect its clinical efficacy. There is a lack of information about inhibition of platelet reactivity by generic preparations.
Aims: To compare the effect of original clopidogrel (clopidogrel bisulphate [Plavix(®)]), generic clopidogrel preparations (clopidogrel hydrochloride [Clopidogrel-Mepha(®)]; clopidogrel besylate [Clopidogrel Sandoz(®)]) and prasugrel (Efient(®)) on platelet reactivity in patients with coronary artery disease.