Publications by authors named "Gerard A de Kort"

Introduction: Lifetime risk of aneurysmal subarachnoid haemorrhage (aSAH) is high (7%) in persons ⩾35 years with hypertension who smoke(d). Whether screening for intracranial aneurysms (IAs) to prevent aSAH is effective in these patients is unknown.

Patients And Methods: Participants were retrieved from a cohort of patients with clinically manifest atherosclerotic vascular disease included between 2012 and 2019 at the University Medical Centre Utrecht (SMART-ORACLE, NCT01932671) in whom CT-angiography (CTA) of intracranial arteries was performed.

View Article and Find Full Text PDF

Background and Purpose- Interventional treatment of unruptured brain arteriovenous malformations (BAVMs) has become increasingly controversial. Because medical therapy is still lacking, we aimed to obtain insight into the disease mechanisms implicated in BAVMs and to identify potential targets for medical treatment to prevent rupture of a BAVM. Methods- We used next-generation RNA sequencing to identify differential expression on a transcriptome-wide level comparing tissue samples of 12 BAVMs to 16 intracranial control arteries.

View Article and Find Full Text PDF

Study Question: What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage?

Methods: This prospective diagnostic study enrolled 298 adults (18-70 years) treated in 22 hospitals in the Netherlands over six years. CT angiography was performed within seven days of haemorrhage. If the result was negative, MRI/MRA was performed four to eight weeks later.

View Article and Find Full Text PDF

Although implanted metallic devices constitute a relative contraindication to magnetic resonance imaging (MRI) scanning, the safety of brain imaging in a patient with a vagus nerve stimulator (VNS) is classified as "conditional," provided that specific manufacturer guidelines are followed when a transmit and receive head coil is used at 1.5 or 3.0 Tesla.

View Article and Find Full Text PDF

Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.

View Article and Find Full Text PDF

Purpose: To assess whether magnetic resonance (MR) angiography can be used as a noninvasive alternative to intraarterial digital subtraction angiography (DSA) to indicate additional treatment in the follow-up of patients with coil-treated intracranial aneurysms.

Materials And Methods: This was an ethics committee-approved multicenter study. Consecutive patients who were scheduled for follow-up intraarterial DSA after coil placement were invited for additional MR angiography after providing written informed consent.

View Article and Find Full Text PDF

Background: The term psychosis refers to a combination of symptoms, without pointing to the origin of these symptoms. In a subset of psychotic patients, symptoms are attributable to an organic disease. It is important to identify these organic causes of psychosis early, as urgent treatment of the primary disease may be required.

View Article and Find Full Text PDF

Background And Purpose: In aneurysms that are adequately occluded 6 months after coiling, the risk of late reopening is largely unknown. We assessed the occurrence of late aneurysm reopening and possible risk factors.

Methods: From January 1995 to June 2005, 1808 intracranial aneurysms were coiled in 1675 patients at 7 medical centers.

View Article and Find Full Text PDF

Background And Purpose: Rates of development of de novo intracranial aneurysms and of growth of untreated additional aneurysms are largely unknown. We performed MRA in a large patient cohort with coiled aneurysms at 5-year follow-up.

Methods: In 276 patients with coiled intracranial aneurysms and 5±0.

View Article and Find Full Text PDF

Background And Purpose: The purpose of this study was to investigate position changes of the vagina after hysterectomy for early stage cervical or endometrial cancer and their impact on CTV-PTV margins. We also studied their correlation with surrounding organ filling.

Materials And Methods: Fifteen patients underwent T2-weighted MR scans before and weekly during the course of their EBRT.

View Article and Find Full Text PDF

Purpose: To analyze the influence of different b-value combinations on apparent diffusion coefficient (ADC)-based differentiation of known malignant and benign tissue in cervical cancer patients.

Materials And Methods: A total of 35 patients with stage IB1, IB2, IIA cervical cancer underwent a 3.0T MRI scan prior to radical hysterectomy and pelvic lymph node dissection.

View Article and Find Full Text PDF

Purpose: To determine the test characteristics of magnetic resonance (MR) angiography in the assessment of occlusion of aneurysms treated with coil placement.

Materials And Methods: This was an ethics committee-approved multicenter study. written informed consent was obtained in 311 patients with 343 aneurysms, who had been treated with coil placement and were scheduled for routine follow-up with intraarterial digital subtraction angiography (DSA).

View Article and Find Full Text PDF

The purpose of this study was to investigate the results of a staged treatment of symptomatic focal nodular hyperplasia (FNH), consisting of first embolization and then resection. A 36-year-old woman presented with pulmonary embolism caused by an inferior caval vein thrombosis owing to external compression by FNH in liver segment I (5.2 x 6.

View Article and Find Full Text PDF

Purpose: To study 3T compared to 1.5T phased array magnetic resonance imaging (MRI) in the presurgical work-up of patients with epilepsy with complex focus localization.

Materials And Methods: In all, 37 patients (>10 years) in preoperative work-up for epilepsy surgery were offered 3T in addition to 1.

View Article and Find Full Text PDF

Aim: Conventional MRI and the recently developed diffusion weighted imaging (DWI) technique both are being used for the detection of pelvic lymph node metastasis in gynaecologic cancers. Little is known about the reproducibility of DWI. This study assesses the reproducibility of pelvic lymph node detection by conventional MRI and DWI.

View Article and Find Full Text PDF

Background And Purpose: For cervical cancer patients the CTV consists of multiple structures, exhibiting complex inter-fraction changes. The purpose of this study is to use weekly MR imaging to derive PTV margins that accommodate these changes.

Materials And Methods: Twenty patients with cervical cancer underwent a T2-weighted MRI exam before and weekly during IMRT.

View Article and Find Full Text PDF

Three-dimensional rotational angiography is capable of exquisite visualization of cerebral blood vessels and their pathophysiology. Unfortunately, images obtained using this modality typically show a small region of interest without exterior landmarks to allow patient-to-image registration, precluding their use for neuronavigation purposes. The aim of this study was to find an alternative technique to enable 3D rotational angiography-guided vascular neurosurgery.

View Article and Find Full Text PDF

Purpose: To prospectively assess the effects of lower tube voltage and various effective tube currents on image quality for computed tomographic (CT) angiography of the circle of Willis.

Materials And Methods: Institutional review board approval was obtained. Patients or family provided written informed consent.

View Article and Find Full Text PDF

Purpose: Investigating the impact of tumor regression on the dose within cervical tumors and surrounding organs, comparing conventional, conformal, and intensity-modulated radiotherapy (IMRT) and the need for repeated treatment planning during irradiation.

Methods And Materials: Fourteen patients with cervical cancer underwent magnetic resonance (MR) imaging before treatment and once during treatment, after about 30 Gy. Target volumes and critical organs were delineated.

View Article and Find Full Text PDF

The purpose of this study was to assess the image quality and diagnostic value of MR urography in detecting abnormalities of the urinary collecting system relevant for the preoperative evaluation of living renal donors. Study subjects were selected from the existing intravenous urography (IVU) reports: 18 consecutive patients with a duplication or another abnormality of the collecting system and 20 consecutive patients with normal anatomy. They underwent a respiratory-triggered 3D T2-weighted fast spin-echo acquisition after oral administration of furosemide, without and with abdominal compression.

View Article and Find Full Text PDF