Academic radiology departments have added increasing numbers of entirely remote "work-from-home" or hybrid faculty. This change has presented both an opportunity to recruit and retain faculty as well as a set of challenges to maintaining the full academic mission and educational environment. In this article we describe our experience with creating a remote faculty position and the key elements that we believe made it successful.
View Article and Find Full Text PDFPurpose: Medical imaging is an increasingly important source of radiation exposure for the general population, and there are risks associated with such exposure; however, recent studies have demonstrated poor understanding of medical radiation among various groups of health care providers. This study had two aims: (1) analyze physicians' knowledge of radiation exposure and risk in diagnostic imaging across multiple specialties and levels of training, and (2) assess the effectiveness of a brief educational presentation on improving physicians' knowledge.
Methods: From 2014 to 2016, 232 health care providers from multiple departments participated in an educational presentation and pre- and postpresentation tests evaluating knowledge of radiation exposure and risk at a large academic institution.
Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model.
Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software.
Purpose To investigate the effect of change in portal vein flow rates on the size and shape of ablations created by a bipolar radiofrequency (RF) ablation device. Materials and Methods This study was exempt from institutional animal care and use committee review. An in vitro bovine liver model perfused with autologous blood via the portal vein at three flow rates (60, 80, 100 mL/min per 100 g of liver) was used.
View Article and Find Full Text PDFThe membership of the Intersociety Committee convened to consider how best to continue to stimulate, nurture, and support innovation in radiologic research and education in the face of ever increasing clinical demands and financial constraints. The topic was chosen in recognition that the growth and success of radiology over the past 50-plus years have been driven by spectacular technological developments in imaging and intervention and that the future relevance of the specialty will hinge on how the specialty continues to evolve. To keep radiology a dynamic and vital component of the health care enterprise will require continued innovation in technology and the requisite education that goes with it.
View Article and Find Full Text PDFDue to increasing rates of international travel, hepatic fascioliasis is appearing in nonendemic areas, where diagnosis can be difficult. We present two confirmed cases of hepatic fascioliasis in a nonendemic region. The purposes of this report are to discuss computed tomography (CT) findings of hepatic fascioliasis and to review the literature.
View Article and Find Full Text PDFPurpose: To investigate the effect of change in portal venous blood flow rates on the size and shape of ablations created by a 2.45-GHz microwave ablation device.
Materials And Methods: This study was exempt from review by the institutional animal care and use committee.
The current initiative to reform health care from both a quality and a cost perspective has already had a profound impact on the radiology enterprise. We have seen a decrease in the utilization of imaging studies, a reduction in reimbursement, a declining payer mix, shrinking incomes, a proliferation of performance indices, creation of radiology mega-groups, growth of national radiology companies, and increasing turf incursions. Our cheese is clearly on the move, and we must take action to reengineer the radiology enterprise.
View Article and Find Full Text PDFImage-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies.
View Article and Find Full Text PDFJ Am Coll Radiol
January 2015
The digital and online revolution is having a profound impact on radiology journals, forcing a migration from print to online publication and altering traditional revenue streams needed to sustain the journals. The 2013 Intersociety Committee Summer Conference attendees reviewed the history of the development of radiology journals, explored the forces driving the transition from print to electronic publication, and examined the impact of the alteration of the traditional revenue streams, such as subscription and advertisement dollars, on the financial sustainability of journals. The attendees also discussed the international movement toward open access to journal content and its impact on a journal's financial viability.
View Article and Find Full Text PDFImage-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies.
View Article and Find Full Text PDFThe ACR Task Force on Medical Student Education in Radiology, in partnership with the Alliance of Medical Student Educators in Radiology, investigated the current status of how and to what extent medical imaging was being taught in medical schools. The task force executed a 3-part survey of medical school deans, radiology department chairs, and intern physicians. The results provided an updated understanding of the status of radiology education in medical schools in the United States.
View Article and Find Full Text PDFPurpose: This study outlines the design and fabrication techniques for two portal vein flow phantoms.
Methods: A materials study was performed as a precursor to this phantom fabrication effort and the desired material properties are restated for continuity. A three-dimensional portal vein pattern was created from the Visual Human database.
Tablet computing and mobile resources are the hot topics in technology today, with that interest spilling into the medical field. To improve resident education, a fully configured iPad, referred to as the "Radiology Resident iPad Toolbox," was created and implemented at the University of Colorado. The goal was to create a portable device with comprehensive educational, clinical, and communication tools that would contain all necessary resources for an entire 4-year radiology residency.
View Article and Find Full Text PDFPurpose: This study investigated the ultrasound, MRI, and CT imaging characteristics of several industrial casting and molding compounds as a precursor to the future development of durable and anatomically correct flow phantoms.
Methods: A set of usability and performance criteria was established for a proposed phantom design capable of supporting liquid flow during imaging. A literature search was conducted to identify the materials and methods previously used in phantom fabrication.
The "new online" (Web 2.0) world is evolving rapidly, and the digital information, education, and networking resources available to radiologists have exploded over the past 2 decades. The 2012 Intersociety Committee Summer Conference attendees explored the online resources that have been produced by societies, universities, and commercial entities.
View Article and Find Full Text PDFThe Intersociety Committee is a freestanding committee of the ACR established to promote collegiality and improve communication among national radiology organizations. The Intersociety Committee began in 1980 with 22 member organizations and has grown to approximately 50 member organizations. Each year, the Intersociety Committee sponsors a summer conference, at which representatives from the member organizations discuss issues facing radiology.
View Article and Find Full Text PDFPurpose: To assess whether there is a significant difference in the effect of incremental changes of portal venous blood flow rates on the size of radiofrequency (RF) versus microwave (MW) ablation lesions in an ex vivo blood-perfused bovine liver model.
Materials And Methods: This study was exempt from approval by the Institutional Animal Care and Use Committee. Sixty ablations (30 MW and 30 RF ablations) were performed ex vivo in 15 bovine livers perfused with autologous blood via the portal vein at 60, 70, 80, 90, and 100 mL/min per 100 g of liver tissue (three livers were used for each flow rate).
The presented cases detail percutaneous radiofrequency (RF) ablation of multiple giant hepatic hemangiomas in two patients who presented with right upper-quadrant pain and fullness and chose not to undergo surgical resection. Treatment of two hemangiomas per patient, 7 cm and 6 cm in one and 9 cm and 2 cm in the other, was accomplished in single ablation sessions with 12 and nine cycles, respectively. Patients had durable resolution of symptoms with reduction of lesion size by 68%-82% at a mean follow-up of 13 months.
View Article and Find Full Text PDFRationale And Objectives: An in vitro perfused bovine liver model was used to evaluate the relationship between the sizes of radiofrequency ablation lesions and variation in portal venous blood flow.
Materials And Methods: Fourteen bovine livers were perfused with autologous heparinized blood at 37°C and 40% to 50% oxygenation via the portal vein. Flow rates were adjusted from 10 to 50 mL/min/100 g tissue.
The member organizations of the Intersociety Conference have agreed that radiology would benefit from consolidation and collaboration of the 50-plus radiology organizations. At this year's annual meeting, the participants concluded that the educational and research missions of the organizations would benefit from the creation of a unified strategic plan that addressed the coordination of annual meetings, online educational materials, research infrastructure, and the creation of a direct relationship between the research initiatives of the organizations and the patient advocacy groups of the Academy of Radiology Research. The socioeconomic mission of the organizations would be enhanced through the creation of a formal communication network with the ACR, and certification could be enhanced by the orchestration of the creation of educational materials related to the maintenance of certification.
View Article and Find Full Text PDF