Proton (p) and carbon (C) ion beams are in clinical use for cancer treatment, although other particles such as He, Be, and B ions have more recently gained attention. Identification of the most optimal ion beam for radiotherapy is a challenging task involving, among others, radiobiological characterization of a beam, which is depth-, energy-, and cell type- dependent. This study uses the FLUKA and MCDS Monte Carlo codes in order to estimate the relative biological effectiveness (RBE) for several ions of potential clinical interest such as p, He, Li, Be, B, and C forming a spread-out Bragg peak (SOBP).
View Article and Find Full Text PDFPreoperative management of rectal carcinoma can be performed by employing either conventionally or hypo-fractionated Radiotherapy (CFRT or HFRT, respectively), delivered by Intensity Modulated Radiotherapy (IMRT) or Volumetric Modulated Arc Therapy (VMAT) plans, employing 6 MV or 10 MV photon beams. This study aims to dosimetrically and radiobiologically compare all available approaches, with emphasis on the risk of radiation-induced second cancer to the bladder and bowel. Computed Tomography (CT) scans and relevant radiotherapy contours from 16 patients were anonymized and analyzed retrospectively.
View Article and Find Full Text PDFColorectal cancer screening has long been recommended for middle age and older individuals. Recent evidence indicates increasing incidence and mortality among young adults. Therefore, the present study re-examined the current recommendations using an asymptomatic average-risk population screened by colonoscopy.
View Article and Find Full Text PDFPurpose: This work aims at promoting target localization accuracy in cranial stereotactic radiosurgery (SRS) applications by focusing on the correction of sequence-dependent (also patient induced) magnetic resonance (MR) distortions at the lesion locations. A phantom-based quality assurance (QA) methodology was developed and implemented for the evaluation of three distortion correction techniques. The same approach was also adapted to cranial MR images used for SRS treatment planning purposes in single or multiple brain metastases cases.
View Article and Find Full Text PDFPurpose: The aim of this study is to introduce a novel DWI-MRI phantom and to compare Apparent Diffusion Coefficient (ADC) measurements, utilizing EPI-DWI and HASTE-DWI sequences and two different fitting algorithms.
Materials And Methods: 23 test tubes with different sucrose concentrations and polyacrylamide gels were used as a phantom for ADC measurements. The phantom was scanned on a clinical MRI system (1.
External beam radiation therapy (RT) is often offered to breast cancer patients after surgical mastectomy followed by breast reconstruction with silicone implants. In some cases, the RT is administered while the patient is still implanted with a temporary tissue expander including a high-density metallic port, which is expected to affect the planned dose distribution. This work uses Monte Carlo (MC) simulation in order to evaluate the aforementioned effect when the McGhan Style 133 Tissue Expander with the Magna-Site injection port is used.
View Article and Find Full Text PDFPurpose: The present report addresses the question of what could be the appropriate dose and dose rate for 125I and 103PD permanent seed implants for breast cancer as monotherapy for early stage breast cancer. This is addressed by employing a radiobiological methodology, which is based on the linear quadratic model, to identify a biologically effective dose (BED) to the prescription point of the brachytherapy implant, which would produce equivalent cell killing (or same cell survival) when compared to a specified external radiotherapy scheme.
Methods: In the present analysis, the tumor and normal tissue BED ratios of brachytherapy and external radiotherapy are examined for different combinations of tumor proliferation constant (K), alpha/beta ratios, initial dose rate (R0), and reference external radiotherapy scheme (50 or 60 Gy in 2 Gy per fraction).