Eur J Obstet Gynecol Reprod Biol
May 2024
Substandard or disrespectful care during labour should be of serious concern for healthcare professionals, as it can affect one of the most important events in a woman's life. Substandard care refers to the use of interventions that are not considered best-practice, to the inadequate execution of interventions, to situations where best-practice interventions are withheld from patients, or there is lack of adequate informed consent. Disrespectful care refers to forms of verbal and non-verbal communication that affect patients' dignity, individuality, privacy, intimacy, or personal beliefs.
View Article and Find Full Text PDFEur J Obstet Gynecol Reprod Biol
March 2024
In high-resource countries, adverse perinatal outcomes are currently rare in term, non-malformed fetuses, undergoing labor, but they remain a leading cause of medico-legal dispute. Precise terminology is important to describe situations related to inadequate fetal oxygenation in labor, to ensure appropriate communication between healthcare professionals and adequate transmission of information to parents. This position statement provides consensus definitions from European perinatologists and midwives regarding the most appropriate terminology to describe situations related to inadequate fetal oxygenation in labor: suspected fetal hypoxia, severe newborn acidemia, newborn metabolic acidosis, and hypoxic-ischemic encephalopathy.
View Article and Find Full Text PDFJ Matern Fetal Neonatal Med
December 2022
OF RECOMMENDATIONS1. Oxytocin for induction or augmentation of labor should not be started when there is a previous scar (such as previous classical cesarean section, uterine perforation or myomectomy when uterine cavity is reached) or in any other condition where labor or vaginal delivery are contraindicated. (; ).
View Article and Find Full Text PDFBackground: In the past century, some areas of obstetric including intrapartum care have been slow to benefit from the dramatic advances in technology and medical care. Although fetal heart rate monitoring (cardiotocography) became available a half century ago, its interpretation often differs between institutions and countries, its diagnostic accuracy needs improvement, and a technology to help reduce the unnecessary obstetric interventions that have accompanied the cardiotocography is urgently needed.
Study Design: During the second half of the 20th century, key findings in animal experiments captured the close relationship between myocardial glycogenolysis, myocardial workload, and ST changes, thus demonstrating that ST waveform analysis of the fetal electrocardiogram can provide information on oxygenation of the fetal myocardium and establishing the physiological basis for the use of electrocardiogram in intrapartum fetal surveillance.