Publications by authors named "George T Harea"

Microfluidic membrane oxygenators are designed to mimic branching vasculature of the native lung during extracorporeal lung support. To date, scaling of such devices to achieve clinically relevant blood flow and lung support has been a limitation. We evaluated a novel multilayer microfluidic blood oxygenator (BLOx) capable of supporting 750-800 ml/min blood flow versus a standard hollow fiber membrane oxygenator (HFMO) in vivo during veno-venous extracorporeal life support for 24 hours in anesthetized, mechanically ventilated uninjured swine (n = 3/group).

View Article and Find Full Text PDF

Device-induced thrombosis remains a major complication of extracorporeal life support (ECLS). To more thoroughly understand how blood components interact with the artificial surfaces of ECLS circuit components, assessment of clot deposition on these surfaces following clinical use is urgently needed. Scanning electron microscopy (SEM), which produces high-resolution images at nanoscale level, allows visualization and characterization of thrombotic deposits on ECLS circuitry.

View Article and Find Full Text PDF

Numerous biomaterials have been developed for application in blood-contacting medical devices to prevent thrombosis; however, few materials have been applied to full-scale devices and evaluated for hemocompatibility under clinical blood flow conditions. We applied a dual-action slippery liquid-infused (LI) nitric oxide (NO)-releasing material modification (LINO) to full-scale blood circulation tubing for extracorporeal lung support and evaluated the tubing ex vivo using swine whole blood circulated for 6 h at a clinically relevant flow. LINO tubing was compared to unmodified tubing (CTRL) and isolated LI and NO-releasing modifications (n = 9/group).

View Article and Find Full Text PDF

Background: Patients with kidney failure are at risk for lethal complications from hyperkalemia. Resuscitation, medications, and hemodialysis are used to mitigate increased potassium (K) levels in circulating blood; however, these approaches may not always be readily available or effective, especially in a resource limited environment. We tested a sorbent cartridge (KC, Kontrol CytoSorbents Medical Inc.

View Article and Find Full Text PDF
Article Synopsis
  • ECMO technology is rapidly evolving due to increasing lung diseases and advancements in its safety and effectiveness, despite existing challenges like clotting and bleeding in the blood circuit.
  • Recent microfluidic advancements allow for precise control over essential design elements, which could lead to enhanced ECMO devices.
  • A new multilayer microfluidic oxygenator has been developed that closely mimics physiological blood flow and shows significant improvements in oxygen transfer and blood flow rates compared to previous designs, with future studies planned for testing in large animals.
View Article and Find Full Text PDF

Medical devices that require substantial contact between blood and a foreign surface would be dramatically safer if constructed from materials that prevent clot formation and coagulation disturbance at the blood-biomaterial interface. Nitric oxide (NO), an endogenous inhibitor of platelet activation in the vascular endothelium, could provide anticoagulation at the blood-surface interface when applied to biomaterials. We investigated an application of a copper-based metal-organic framework, H[(CuCl)(BTTri)-(HO)]·72HO where HBTTri = 1,3,5-tris(1-1,2,3-triazole-5-yl)benzene] (CuBTTri), which has been shown to be an effective catalyst to generate NO from -nitrosothiols that are endogenously present in blood.

View Article and Find Full Text PDF

Background: We assessed the use of an FDA-cleared transport ventilator with limited functions and settings during ground transport in a swine model of ground evacuation. We hypothesized that when used as an adjunct to extracorporeal life support (ECLS), the device would enable safe mobile ventilatory support during ground evacuation.

Methods: Female Yorkshire swine (n = 11; mean, 52.

View Article and Find Full Text PDF

The recent emergence of microfluidic extracorporeal lung support technologies presents an opportunity to achieve high gas transfer efficiency and improved hemocompatibility relative to the current standard of care in extracorporeal membrane oxygenation (ECMO). However, a critical challenge in the field is the ability to scale these devices to clinically relevant blood flow rates, in part because the typically very low blood flow in a single layer of a microfluidic oxygenator device requires stacking of a logistically challenging number of layers. We have developed biomimetic microfluidic oxygenators for the past decade and report here on the development of a high-flow (30 mL/min) single-layer prototype, scalable to larger structures via stacking and assembly with blood distribution manifolds.

View Article and Find Full Text PDF

Introduction: Extracorporeal life support (ECLS) patients are at risk for complications caused by gaseous microemboli (GME). GMEs can cause hypoxia, inflammation, coagulation, and end-organ damage. The objective of this in vitro study was to assess dynamics of GME formation during circulation of whole blood or a glycerol blood surrogate.

View Article and Find Full Text PDF

Coagulopathic complications during extracorporeal life support (ECLS) result from two parallel processes: 1) foreign surface contact and shear stress during blood circulation and 2) administration of anticoagulant drugs to prevent circuit thrombosis. To address these problems, biocompatible surfaces are developed to prevent foreign surface-induced coagulopathy, reducing or eliminating the need for anticoagulants. Tethered liquid perfluorocarbon (TLP) is a nonadhesive coating that prevents adsorption of plasma proteins and thrombus deposition.

View Article and Find Full Text PDF

Background: We investigated the expression of high mobility group box 1 (HMGB1) protein in a combat-relevant polytrauma/ acute respiratory distress syndrome (ARDS) model. We hypothesized that systemic HMGB1 expression is increased after injury and during aeromedical evacuation (AE) at altitude.

Methods: Female Yorkshire swine (n =15) were anesthetized and cannulated with a 23Fr dual-lumen catheter.

View Article and Find Full Text PDF

Coagulation management is the leading challenge during extracorporeal life support (ECLS) due to shear stress and foreign-surface-induced coagulation disturbance during circulation. A nonadhesive, liquid-infused coating called tethered liquid perfluorocarbon (TLP) was developed to prevent adhesion of blood on medical materials. We investigated the novel application of TLP to commercial ECLS circuits compared with standard heparin-coated circuits in vivo in anesthetized swine for 6 hours veno-venous ECLS (1 L/min blood flow) without systemic anticoagulation (n = 3/group).

View Article and Find Full Text PDF

Background: Coagulation monitoring capabilities during transport are limited. Thromboelastography (TEG) is a whole-blood clotting test measuring clot formation, stabilization, and fibrinolysis and is traditionally performed in a laboratory. We evaluated a new point-of-care TEG analyzer, TEG 6s (Haemonetics, Braintree, MA), in a large animal model of combat-relevant trauma managed with extracorporeal life support during ground and high-altitude aeromedical evacuation.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionspu1nsgmbdgi2v9vb6s2ihh0p5kp68ov): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once