Stroke is a very frequent disorder and one of the major leading causes of death and disability worldwide. Timely detection of stroke is essential in order to select and perform the correct treatment strategy. Thus, the use of an efficient imaging method for an early diagnosis of this syndrome could result in an increased survival's rate.
View Article and Find Full Text PDFWe present a radio-frequency-activated switching system that can automatically detune a metamaterial resonator to enhance magnetic resonance imaging (MRI) performance. Local sensitivity-enhancing metamaterials typically consist of resonant components, which means that the transmitted radio frequency field is spatially inhomogeneous. The switching system shows for the first time that a metamaterial resonator can be detuned during transmission and tuned during reception using a digital circuit.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2019
Magnetic resonance imaging (MRI) is a widely used clinical tool for medical diagnosis and therapy. Several research studies focus on passively improving MRI sensitivity using high dielectric constant (HDC) materials and metamaterials. In this work, we investigate a new metasurface resonator which can enhance local transmit and receive efficiency in 1.
View Article and Find Full Text PDFWe present an approach to enhance microwave brain imaging with an innovative metamaterial (MM) planar design based on a cross-shaped split-ring resonator (SRR-CS). The proposed metasurface is incorporated in different setups, and its interaction with EM waves is studied both experimentally and by using CST Microwave Studio and is compared to a "no MM" case scenario. We show that the MM can enhance the penetration of the transmitted signals into the human head when placed in contact with skin tissue, acting as an impedance-matching layer.
View Article and Find Full Text PDFWe present a first prototype of a wideband microwave tomography system with potential application to medical imaging. The system relies on a compact and robust printed monopole antenna which can operate in the 1.0⁻3.
View Article and Find Full Text PDFWe present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples.
View Article and Find Full Text PDF