Publications by authors named "George Donati"

The traditional external standard calibration method (EC) is automated and simplified using a four-port switching valve (SV4) and a multi-signal approach that enables the generation of several calibration points from a single calibration solution. The SV4-EC method is applied to inductively coupled plasma optical emission spectrometry (ICP-OES) and is based on gradient dilution taking place within the instrument's sample introduction tubing. Both the calibration solution and the samples are diluted by a blank solution containing an internal standard species.

View Article and Find Full Text PDF

Urinary tract infections (UTIs) are a major global health problem and are caused predominantly by uropathogenic (UPEC). UTIs are a leading cause of prescription antimicrobial use. Incessant increase in antimicrobial resistance in UPEC and other uropathogens poses a serious threat to the current treatment practices.

View Article and Find Full Text PDF

The use of mouthguards is advocated by the American Dental Association for orofacial injury prevention and teeth protection. However, the chemical environment in the mouth may cause harmful substances within the mouthguard's polymer material to leach out and be absorbed by the user. Considering this, the present study for the first time analyzed commercially available mouthguards and disclosed the presence of trace elements.

View Article and Find Full Text PDF

Urinary tract infection (UTI) is a ubiquitous infectious condition, and uropathogenic (UPEC) is the predominant causative agent of UTI. Copper (Cu) is implicated in innate immunity, including against UPEC. Cu is a trace element utilized as a co-factor, but excess Cu is toxic due to mismetalation of non-cognate proteins.

View Article and Find Full Text PDF

Nickel-metal hydride batteries (NiMH) are a secondary source of high aggregate value elements, such as nickel, manganese, cobalt, and rare earths, for which recycling typically involves acid lixiviation. Designing the recycling process requires accurate determination of the elements in the leachates, which is hindered by the high complexity of the matrix. In the present study, microwave-induced plasma atomic emission spectrometry (MIP-OES) was selected as the quantitative method for elemental analysis because of its environment friendliness and cost-effectiveness.

View Article and Find Full Text PDF

Background: The effects of coronavirus disease 2019 (COVID-19) remain a global public health emergency because of the ensuing economic burden and death. With robust research into vaccines, antibody treatments, and antiviral drugs for COVID-19, there is still a dearth of evidence on the role of an individual's nutritional status on the severity of COVID-19.

Objective: This study aimed to investigate the association between selenium (Se) and zinc (Zn) status and COVID-19 severity among individuals diagnosed with COVID-19 in North Carolina.

View Article and Find Full Text PDF

Approximately one-in-ten reproductive age adults in the USA follow a plant-based diet, yet there is limited information on the influence of vegan and vegetarian diets on the mineral composition of breast milk. This study explored the major and trace mineral composition in breast milk and associations with maternal diet patterns. We used a cross-sectional design to collect a single sample of breast milk from individuals following vegan ( 23), vegetarian ( 19) and omnivore ( 21) diet patterns.

View Article and Find Full Text PDF

Breast milk iodine concentration (BMIC) from vegan and vegetarian lactating mothers has not previously been evaluated. The goal of this study was to assess BMIC from vegans, vegetarians, and omnivores and to assess intake of iodine by breastfed infants. Breast milk samples from vegans ( = 12), vegetarians ( = 6), and omnivores ( = 12) living in the United States were analyzed.

View Article and Find Full Text PDF

Raman spectroscopy (RS) was used to identify and quantify different nitrogen species in fertilizers. This is a fast and inexpensive method that requires no extensive sample preparation. Urea and nitrate were determined at 1000 and 1045 cm, respectively.

View Article and Find Full Text PDF

Several species are simultaneously used for internal standardization to improve accuracy in inductively coupled plasma optical emission spectrometry (ICP-OES). In multi-internal standard calibration (MISC), signal ratios between the analyte and each of several internal standard species are used for calibration. A single calibration solution is required, and the MISC graph is built with intensity ratios calculated with analytical signals recorded for the sample (I) on the y-axis, while those recorded for the calibration standard (I) are plot on the x-axis (i.

View Article and Find Full Text PDF

The contamination of water sources by anthropogenic activities is a topic of growing interest in the scientific community. Therefore, robust analytical techniques for the determination and quantification of multiple substances are needed, which often require complex and time-consuming procedures. In this context, we describe a univariate calibration method to determine emerging multi-class contaminants in different water sources.

View Article and Find Full Text PDF

Background: Precisely how silver nanoparticles (AgNPs) kill mammalian cells still is not fully understood. It is not clear if AgNP-induced damage differs from silver cation (Ag), nor is it known how AgNP damage is transmitted from cell membranes, including endosomes, to other organelles. Cells can differ in relative sensitivity to AgNPs or Ag, which adds another layer of complexity to identifying specific mechanisms of action.

View Article and Find Full Text PDF

Urinary tract infection (UTI) is one of the most common infectious conditions affecting people in the United States and around the world. Our knowledge of the host-pathogen interaction during UTI caused by Gram-positive bacterial uropathogens is limited compared to that for Gram-negative pathogens. Here, we investigated whether copper and the primary copper-containing protein, ceruloplasmin, are mobilized to urine during naturally occurring UTI caused by Gram-positive uropathogens in patients.

View Article and Find Full Text PDF

Molecular profiling of tumors shows that triple-negative breast cancer (TNBC) can be stratified into mesenchymal (claudin-low breast cancer; CLBC) and epithelial subtypes (basal-like breast cancer; BLBC). Subtypes differ in underlying genetics and in response to therapeutics. Several reports indicate that therapeutic strategies that induce lipid peroxidation or proteotoxicity may be particularly effective for various cancers with a mesenchymal phenotype such as CLBC, for which no specific treatment regimens exist and outcomes are poor.

View Article and Find Full Text PDF

Copper (Cu) is a key transition metal that is involved in many important biological processes in a cell. Cu is also utilized by the immune system to hamper pathogen growth during infection. However, genome-level knowledge on the mechanisms involved in adaptation to Cu stress is limited.

View Article and Find Full Text PDF

The effect of genetic crossing and nutritional management on weight gain and the concentration of minerals and trace elements in the carcass, blood, leather, and viscera of sheep were evaluated. Several statistical strategies were used to evaluate the different elemental composition characteristics of pure breed animals, i.e.

View Article and Find Full Text PDF

The extrapolation approach, traditionally used with standard additions (SA), is compared with the alternative strategies of interpolation, reversed-axis, and normalization. The interpolation approach is based on employing twice the analytical signal recorded for the sample (y) to determine an unknown analyte concentration. In the reversed-axis strategy, x- and y-axes are swapped when building the SA calibration plot to facilitate uncertainty estimation.

View Article and Find Full Text PDF

Supervised and unsupervised machine learning methods are used to evaluate matrix effects caused by carbon and easily ionizable elements (EIEs) on analytical signals of inductively coupled plasma optical emission spectrometry (ICP OES). A simple experimental approach was used to produce a series of synthetic solutions with varying levels of matrix complexity. Analytical lines (n = 29), with total line energies (E) in the 5.

View Article and Find Full Text PDF

Few schools and child care facilities test for Pb in their drinking water. Reviewing the United States Environmental Protection Agency Lead and Copper rule data can contribute to guiding future legislation on Pb testing. This work aims to (i) identify variations in Pb levels in North Carolina school and child care drinking water by building age, (ii) evaluate the effect of corrosion control measures on reducing these levels, and (iii) evaluate the adequacy of Pb reporting limits according to modern instrumentation.

View Article and Find Full Text PDF

Copper and superoxide are used by the phagocytes to kill bacteria. Copper is a host effector encountered by uropathogenic Escherichia coli (UPEC) during urinary tract infection in a non-human primate model, and in humans. UPEC is exposed to higher levels of copper in the gut prior to entering the urinary tract.

View Article and Find Full Text PDF

Nanoparticles offer many promising advantages for improving current surgical regimens through their ability to detect and treat disseminated colorectal cancer (CRC). Hybrid Donor-Acceptor Polymer Particles (HDAPPs) have recently been shown to fluorescently detect and thermally ablate tumors in a murine model. Here, HDAPPS were functionalized with hyaluronic acid (HA) to improve their binding specificity to CT26 mouse CRC cells using HA to target the cancer stem cell marker CD44.

View Article and Find Full Text PDF

Silver nanoparticles (AgNPs) show promise for treatment of aggressive cancers including triple-negative breast cancer (TNBC) in preclinical cancer models. For clinical development of AgNP-based therapeutics, it will be necessary to clearly define the specific physicochemical features of the nanoparticles that will be used, and to tie these properties to biological outcomes. To fill this knowledge gap, we performed thorough structure/function, mechanistic, safety, and efficacy studies to assess the potential for AgNPs to treat TNBC.

View Article and Find Full Text PDF

Grasses accumulate high concentrations of silicon (Si) in their tissues, with potential benefits including herbivore defense, improved water balance, and reduced leaf construction costs. Although Si is one of the most widely varying leaf constituents among individuals, species, and ecosystems, the environmental forces driving this variation remain elusive and understudied. To understand relationships between environmental factors and grass Si accumulation better, we analyzed foliar chemistry of grasses from 17 globally distributed sites where nutrient inputs and grazing were manipulated.

View Article and Find Full Text PDF

Selenium deficiency has been linked to anemia of inflammation, which is mediated by hepcidin. However, there are few studies providing evidence of the role of hepcidin in this relationship. In this study, we investigated the interrelationships among selenium biomarkers, hepcidin concentration, and iron status among individuals with overweight/obesity compared to their normal weight counterparts, since obesity is associated with chronic inflammation.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session9pqa58k3g8fu363q3cvedb8jli42nat7): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once