Publications by authors named "George Bolcsfoldi"

As recommended by the mouse lymphoma assay (MLA) Workgroup of the International Workshop on Genotoxicity Testing (Aberdeen, 2003), a trend test is critical if an induced mutant frequency (MF) of at least 126 × 10(-6) (global evaluation factor, GEF) is achieved at one or more test concentrations. Only those responses that both achieve the GEF and a significant trend are biologically relevant. While no specific trend test was recommended by the Workshop, a trend test was recommended by the UK Environmental Mutagen Society (1989).

View Article and Find Full Text PDF

An improved protocol for the radiolabel DNA-binding assay, which gives a high yield of highly pure DNA has been developed by use of mouse lymphoma cells. The critical difference from previously published methods is the use of enzymatic degradation of proteins in the later DNA purification steps rather than during the homogenisation procedure. Different DNA-purification methodologies were first compared and the protocol of choice was optimized later on; both steps were performed with [(35)S]-labelled amino acids for labelling of cellular protein, which enabled both the quantification of cellular protein contaminating the DNA sample and the distinction between cellular and enzyme-derived protein.

View Article and Find Full Text PDF
Article Synopsis
  • The Mouse Lymphoma Assay (MLA) Workgroup, consisting of global experts, met on September 9, 2005, to reach consensus on the 24-hour treatment protocol in genotoxicity testing.
  • Recommendations were made regarding acceptable values for negative and positive controls, including mutant frequency and cloning efficiency.
  • The Workgroup supported the inclusion of 24-hour treatments without S-9 in the MLA assay when shorter treatments yielded negative results, aligning with International Committee on Harmonization guidelines.
View Article and Find Full Text PDF

The Mouse Lymphoma Assay (MLA) Workgroup of the International Workshop on Genotoxicity Testing (IWGT), comprised of experts from Japan, Europe, and the United States, met on August 29, 2003, in Aberdeen, Scotland, United Kingdom. This meeting of the MLA Workgroup was devoted to reaching a consensus on the appropriate approach to data evaluation and on acceptance criteria for both the positive and negative/vehicle controls. The Workgroup reached consensus on the acceptance criteria for both the agar and microwell versions of the MLA.

View Article and Find Full Text PDF

An interlaboratory study was performed to validate an anti-CD71/flow cytometry-based technique for enumerating micronucleated reticulocytes (MN-RETs) in mouse peripheral blood. These experiments were designed to address International Workshop on Genotoxicity Test Procedures validation criteria by evaluating the degree of correspondence between MN-RET measurements generated by flow cytometry (FCM) with those obtained using traditional microscopy-based methods. In addition to these cross-methods data, flow cytometric MN-RET measurements for each blood sample were performed at two separate sites in order to evaluate the reproducibility of data between laboratories.

View Article and Find Full Text PDF

Experiments described herein were designed to evaluate the performance characteristics of a flow cytometry-based system that scores the incidence of peripheral blood micronucleated reticulocytes (MN-RETs). These procedures represent the continued refinement of a previously reported anti-CD71-based method (Dertinger et al. [1996]: Mutat Res 371:283-292), with the following modifications: incorporation of a third fluorescent label to exclude platelets from the MN-RET region, and use of a CD71-associated fluorescence thresholding technique to increase data acquisition rates.

View Article and Find Full Text PDF

The Mouse Lymphoma Assay (MLA) Workgroup of the International Workshop on Genotoxicity Tests (IWGT) met on June 28th and 29th, 2002, in Plymouth, England. This meeting of the MLA group was devoted to discussing the criteria for assay acceptance and appropriate approaches to data evaluation. Prior to the meeting, the group conducted an extensive analysis of data from both the microwell and soft agar versions of the assay.

View Article and Find Full Text PDF

Extended-term cultures of human lymphocytes provide a source of uniform human cells that can be used for several experiments performed over a long time, avoiding the variability arising from taking blood samples for individual experiments. The use of extended-term cultures of human T-lymphocytes in the alkaline single-cell gel electrophoresis assay (comet assay) was evaluated as a test for the potential genotoxicity of chemicals. The DNA-damaging effects of five DNA-reactive mutagens and clastogens (benzo[a]pyrene, cyclophosphamide, formaldehyde, 4-nitroquinoline-N-oxide (4NQO) and N-nitrosopiperidine) was determined and compared with the effects of one non-DNA-reactive mutagen (5-hydroxyurea), and one non-mutagenic agent (ethanol).

View Article and Find Full Text PDF

The Mouse Lymphoma Assay (MLA) Workgroup of the International Workshop on Genotoxicity Test Procedures held a second harmonization meeting just prior to the U.S. Environmental Mutagen Society Meeting in New Orleans, LA, in April 2000.

View Article and Find Full Text PDF

Fluorescence microscopy of A549 cells stained with a glutathione (L-gamma-glutamyl-L-cysteinylglycine, GSH)-specific polyclonal antibody displayed uniform staining of the peri-nuclear cytosol, with the nuclear region apparently lacking GSH staining. This discontinuous staining was confirmed in other cell types and also corroborated in A549 cells stained with the thiol-reactive dye mercury orange. The selectivity of antibody binding was confirmed by buthionine sulfoximine (BSO)-dependent inhibition of GSH synthesis.

View Article and Find Full Text PDF