Knowledge of both tibio-femoral kinematics and kinetics is necessary for fully understanding knee joint biomechanics, guiding implant design and testing, and driving and validating computational models. In 2017, the CAMS-Knee datasets were presented, containing synchronized in vivo implant kinematics measured using a moving fluoroscope and tibio-femoral contact loads measured using instrumented implants from six subjects. However, to date, no representative summary of kinematics and kinetics obtained from measurements at the joint level of the same cohort of subjects exists.
View Article and Find Full Text PDFThe long term performance of total knee arthroplasty (TKA) with regards to the bearing materials is related to the aging behaviour of these materials. The use of highly crosslinked materials in hip arthroplasty improved the clinical outcome. Nevertheless, the outcome for these materials compared to conventional UHMWPE (ultra-high molecular weight polyethylene) remains controversial in TKA and alternative bearing materials may be advantageous to improve its outcome in the second and third decade.
View Article and Find Full Text PDFBackground: Hip joint loading is dominated by muscular activity. Thus, contact forces exceeding many times one's body weight are a consequence of imbalanced muscular activity. The objective was to analyze the influence of muscle atrophy after total hip arthroplasty on in vivo hip joint contact loading initially and long term.
View Article and Find Full Text PDFDuring whole body vibrations, the total contact force in knee and hip joints consists of a static component plus the vibration-induced dynamic component. In two different cohorts, these forces were measured with instrumented joint implants at different vibration frequencies and amplitudes. For three standing positions on two platforms, the dynamic forces were compared to the static forces, and the total forces were related to the peak forces during walking.
View Article and Find Full Text PDFJ Bone Joint Surg Am
October 2018
Background: High friction moments in hip implants contribute to the aseptic loosening of cementless cups, of which there are approximately 100,000 cases per year; sustained joint loading may cause such high moments. The most "critical" physical activities associated with sustained joint loading were identified in this study.
Methods: Friction moments in the cup were telemetrically measured about 33,000 times in the endoprostheses of 9 subjects during >1,400 different activities.
Combined knowledge of the functional kinematics and kinetics of the human body is critical for understanding a wide range of biomechanical processes including musculoskeletal adaptation, injury mechanics, and orthopaedic treatment outcome, but also for validation of musculoskeletal models. Until now, however, no datasets that include internal loading conditions (kinetics), synchronized with advanced kinematic analyses in multiple subjects have been available. Our goal was to provide such datasets and thereby foster a new understanding of how in vivo knee joint movement and contact forces are interlinked - and thereby impact biomechanical interpretation of any new knee replacement design.
View Article and Find Full Text PDFIntroduction: It has been suspected that friction in hip implants is higher when walking is initiated after a resting period than during continuous movement. It cannot be excluded that such increased initial moments endanger the cup fixation in the acetabulum, overstress the taper connections in the implant or increase wear. To assess these risks, the contact forces, friction moments and friction coefficients in the joint were measured in vivo in ten subjects.
View Article and Find Full Text PDFAquatic exercises are widely used for rehabilitation or preventive therapies in order to enable mobilization and muscle strengthening while minimizing joint loading of the lower limb. The load reducing effect of water due to buoyancy is a main advantage compared to exercises on land. However, also drag forces have to be considered that act opposite to the relative motion of the body segments and require higher muscle activity.
View Article and Find Full Text PDFWalking is a task that we seek to understand because it is the most relevant human locomotion. Walking causes complex loading patterns and high load magnitudes within the human body. This work summarizes partially published load data collected in earlier in vivo measurement studies on 9 patients with telemeterized knee endoprostheses, 10 with hip endoprostheses and 5 with vertebral body replacements.
View Article and Find Full Text PDFUnlabelled: As total knee arthroplasty (TKA) patients are getting more active, heavier and younger and structural material fatigue and delamination of tibial inserts becomes more likely in the second decade of good clinical performance it appears desirable to establish advanced pre-clinical test methods better characterizing the longterm clinical material behaviour. The questions of our study were 1) Is it possible to induce subsurface delamination and striated pattern wear on standard polyethylene TKA gliding surfaces? 2) Can we distinguish between γ-inert standard polyethylene (PEstand.30kGy) as clinical reference and vitamin E stabilised materials (PEVit.
View Article and Find Full Text PDFWith the increasing success of hip joint replacements, the average age of patients has decreased, patients have become more active and their expectations of the implant durability have risen. Thus, pre-clinical endurance tests on hip implants require defining realistic in vivo loads from younger and more active patients. These loads require simplifications to be applicable for simulator tests and numerical analyses.
View Article and Find Full Text PDFThe repeated lifting of heavy weights has been identified as a risk factor for low back pain (LBP). Whether squat lifting leads to lower spinal loads than stoop lifting and whether lifting a weight laterally results in smaller forces than lifting the same weight in front of the body remain matters of debate. Instrumented vertebral body replacements (VBRs) were used to measure the in vivo load in the lumbar spine in three patients at level L1 and in one patient at level L3.
View Article and Find Full Text PDFClin Biomech (Bristol)
October 2015
Background: The medial knee contact force may be lowered by modified foot loading to prevent the progression of unilateral gonarthrosis but the real effects of such gait modifications are unknown. This study investigates how walking with a more medial or lateral rollover of the foot influences the in vivo measured knee contact forces.
Methods: Five subjects with telemeterized knee implants walked on a treadmill with pronounced lateral or medial foot loading.
Loosening of the artificial cup and inlay is the most common reasons for total hip replacement failures. Polyethylene wear and aseptic loosening are frequent reasons. Furthermore, over the past few decades, the population of patients receiving total hip replacements has become younger and more active.
View Article and Find Full Text PDFKnowledge of in vivo spinal loads and muscle forces remains limited but is necessary for spinal biomechanical research. To assess the in vivo spinal loads, measurements with telemeterised vertebral body replacements were performed in four patients. The following postures were investigated: (a) standing with arms hanging down on sides, (b) holding dumbbells to subject the patient to a vertical load, and (c) the forward elevation of arms for creating an additional flexion moment.
View Article and Find Full Text PDFKnowledge about in vivo spinal loads is required for the identification of risk factors for low back pain and for realistic preclinical testing of spinal implants. Therefore, the aim of the present study was to measure the in vivo forces on a vertebral body replacement (VBR) during trunk flexion and to analyze in detail the typical relationship between trunk inclination and spinal load. Telemeterized VBRs were implanted in five patients.
View Article and Find Full Text PDFThe wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty.
View Article and Find Full Text PDFAfter spinal surgery, physiotherapeutic exercises are performed to achieve a rapid return to normal life. One important aim of treatment is to regain muscle strength, but it is known that muscle forces increase the spinal loads to potentially hazardous levels. It has not yet been clarified which exercises cause high spinal forces and thus endanger the surgical outcome.
View Article and Find Full Text PDFActivities with high spinal loads should be avoided by patients with back problems. Awareness about these activities and knowledge of the associated loads are important for the proper design and pre-clinical testing of spinal implants. The loads on an instrumented vertebral body replacement have been telemetrically measured for approximately 1000 combinations of activities and parameters in 5 patients over a period up to 65 months postoperatively.
View Article and Find Full Text PDFCycling on an ergometer is an effective exercise for improving fitness. However, people with back problems or previous spinal surgery are often not aware of whether cycling could be harmful for them. To date, little information exists about spinal loads during cycling.
View Article and Find Full Text PDFObjective: The external knee adduction moment (EAM) is often considered a surrogate measure of the distribution of loads across the tibiofemoral joint during walking. This study was undertaken to quantify the relationship between the EAM and directly measured medial tibiofemoral contact forces (Fmed ) in a sample of subjects across a spectrum of activities.
Methods: The EAM for 9 patients who underwent total knee replacement was calculated using inverse dynamics analysis, while telemetric implants provided Fmed for multiple repetitions of 10 activities, including walking, stair negotiation, sit-to-stand activities, and squatting.
The loads acting in knee joints must be known for improving joint replacement, surgical procedures, physiotherapy, biomechanical computer simulations, and to advise patients with osteoarthritis or fractures about what activities to avoid. Such data would also allow verification of test standards for knee implants. This work analyzes data from 8 subjects with instrumented knee implants, which allowed measuring the contact forces and moments acting in the joint.
View Article and Find Full Text PDFThe external knee adduction moment is considered a surrogate measure for the medial tibiofemoral contact force and is commonly used to quantify the load reducing effect of orthopedic interventions. However, only limited and controversial data exist about the correlation between adduction moment and medial force. The objective of this study was to examine whether the adduction moment is indeed a strong predictor for the medial force by determining their correlation during gait.
View Article and Find Full Text PDFFriction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used.
View Article and Find Full Text PDFIntroduction: After hip surgery, it is the orthopedist's decision to allow full weight bearing to prevent complications or to prescribe partial weight bearing for bone ingrowth or fracture consolidation. While most loading conditions in the hip joint during activities of daily living are known, it remains unclear how demanding physiotherapeutic exercises are. Recommendations for clinical rehabilitation have been established, but these guidelines vary and have not been scientifically confirmed.
View Article and Find Full Text PDF