Arsenic (As)-bearing Fe(III) precipitate groundwater treatment sludge has traditionally been viewed by the water sector as a disposal issue rather than a resource opportunity, partly due to assumptions of the low value of As. However, As has now been classified as a Critical Raw Material (CRM) in many regions, providing new incentives to recover As and other useful components of the sludge, such as phosphate (P) and the reactive hydrous ferric oxide (HFO) sorbent. Here, we investigate alkali extraction to separate As from a variety of field and synthetic As-bearing HFO sludges, which is a critical first step to enable sludge upcycling.
View Article and Find Full Text PDFLong-term consumption of groundwater containing elevated levels of arsenic (As) can have severe health consequences, including cancer. To effectively remove As, conventional treatment technologies require expensive chemical oxidants to oxidise neutral arsenite (As(III)) in groundwater to negatively charged arsenate (As(V)), which is more easily removed. Rapid sand filter beds used in conventional aeration-filtration to treat anaerobic groundwater can naturally oxidise As(III) through biological processes but require an additional step to remove the generated As(V), adding complexity and cost.
View Article and Find Full Text PDFThe co-precipitation of Fe(III) (oxyhydr)oxides with arsenic (As) is one of the most widespread approaches to treat As-contaminated groundwater in both low- and high-income settings. Fe-based co-precipitation of As occurs in a variety of conventional and decentralized treatment schemes, including aeration and sand filtration, ferric chloride addition and technologies based on controlled corrosion of Fe(0) (i.e.
View Article and Find Full Text PDFIndustrial wastewater containing heavy metals, such as Cd and Pb, must be treated prior to discharge to meet increasingly stringent discharge guidelines and to limit the impact of toxic metals on ecosystems and human health. The application of olivine particles is a natural mineral-based solution to treat heavy metal-laden wastewaters, but little is known about the efficiency and mechanism of metal removal by this solid phase. In this work, we investigate the potential of olivine for heavy metal treatment by combining batch metal removal experiments with solid-phase characterization by synchrotron-based X-ray techniques and electron microscopy.
View Article and Find Full Text PDFIron (Fe)-based treatment methods are widely applied to remove carcinogenic arsenic (As) from drinking water, but generate toxic As-laden Fe (oxyhydr)oxide waste that has traditionally been ignored for resource recovery by the water sector. However, the European Commission recently classified As as a Critical Raw Material (CRM), thus providing new incentives to re-think As-laden groundwater treatment sludge. Before As recovery techniques can be developed for groundwater treatment waste, detailed information on its structure and composition is essential.
View Article and Find Full Text PDFIron (Fe)-based groundwater treatment removes carcinogenic arsenic (As) effectively but generates toxic As-rich Fe oxide water treatment residuals (As WTRs) that must be managed appropriately to prevent environmental contamination. In this study, we apply life cycle assessment (LCA) to compare the toxicity impacts of four common As WTR disposal strategies that have different infrastructure requirements and waste control: (i) landfilling, (ii) brick stabilization, (iii) mixture with organic waste, and (iv) open disposal. The As disposal toxicity impacts (functional unit = 1.
View Article and Find Full Text PDFGroundwater contaminated with arsenic (As) must be treated prior to drinking, as human exposure to As at toxic levels can cause various diseases including cancer. Conventional aeration-filtration applied to anaerobic arsenite (As(III)) contaminated groundwater can remove As(III) by co-oxidizing native iron (Fe(II)) and As(III) with oxygen (O). However, the As(III) removal efficiency of conventional aeration can be low, in part, because of incomplete As(III) oxidation to readily-sorbed arsenate (As(V)).
View Article and Find Full Text PDFManganese oxide-coated sand can oxidize electron-rich organic contaminants, but after extended exposure to contaminated water its reactivity decreases. To assess the potential for regenerating geomedia, we measured the ability of passivated manganese-oxide coated sand to oxidize bisphenol A after treatment with oxidants, acid, or methanol. Among the regenerants studied, KMnO, HOCl, HOBr, and pH 2 or 3 HCl solutions raised the average oxidation state of the Mn, but only HOCl and HOBr restored the reactivity of passivated geomedia to levels comparable to those of the virgin manganese-oxide coated sand.
View Article and Find Full Text PDFEffective arsenic (As) removal from groundwater is a pressing need in view of increasingly stringent As drinking water limits in some US states and European countries. In this study, we compared the addition of weak (O), intermediate (NaOCl), and strong (KMnO) groundwater oxidants on the fate of As during As(III), Fe(II), and Mn(II) co-oxidation. Experiments were performed with 50 μg/L As(III), 5 mg/L Fe(II), and 0.
View Article and Find Full Text PDFArsenic (As) is a toxic element present in many (ground)water sources in the world. Most conventional As removal techniques require pre-oxidation of the neutral arsenite (As(III)) species to the negatively charged arsenate (As(V)) oxyanion to optimize As removal and minimize chemical use. In this work, a novel, continuous-flow As removal system was developed that combines biological As(III) oxidation by bacteria with Fe electrocoagulation (EC), an Fe(0)-based electrochemical technology that generates reactive Fe(III) precipitates to bind As.
View Article and Find Full Text PDFSorption of nutrients such as phosphate (P) and silicate (Si) by ferric iron (oxyhydr)oxides (FeOx) modulates nutrient mobility and alters the structure and reactivity of the FeOx. We investigated the impact of these interactions on FeOx transformations using a novel approach with samplers containing synthetic FeOx embedded in diffusive hydrogels. The FeOx were prepared by Fe(III) hydrolysis and Fe(II) oxidation, in the absence and presence of P or Si.
View Article and Find Full Text PDFMillions of people are exposed to toxic levels of dissolved arsenic in groundwater used for drinking. Iron electrocoagulation (FeEC) has been demonstrated as an effective technology to remove arsenic at an affordable price. However, FeEC requires long operating times (∼hours) to remove dissolved arsenic due to inherent kinetics limitations.
View Article and Find Full Text PDFIron electrocoagulation (Fe-EC) is an effective technology to remove arsenic (As) from groundwater used for drinking. A commonly noted limitation of Fe-EC is fouling or passivation of electrode surfaces via rust accumulation over long-term use. In this study, we examined the effect of removing electrode surface layers on the performance of a large-scale (10,000 L/d capacity) Fe-EC plant in West Bengal, India.
View Article and Find Full Text PDFConsumption of drinking water containing arsenic at concentrations even below the World Health Organization provisional limit of 10 μg/L can still lead to unacceptable health risks. Consequently, the drinking water sector in the Netherlands has recently agreed to target 1 μg/L of arsenic in treated water. Unfortunately, in many poor, arsenic-affected countries, the costs and complexity of current methods that can achieve <1 μg/L are prohibitive, which highlights the need for innovative methods that can remove arsenic to <1 μg/L without costly support infrastructure and complicated supply chains.
View Article and Find Full Text PDFEnviron Sci Process Impacts
September 2019
We investigated the impact of aging-induced structural modifications of carbonate green rust (GR), a mixed valent Fe(ii,iii) (hydr)oxide with a high oxyanion sorption affinity, on the partitioning and binding mode of arsenic (As). Suspensions of carbonate GR were produced in the presence of As(v) or As(iii) (i.e.
View Article and Find Full Text PDFIron (oxyhydr)oxides (FeOx) control retention of dissolved nutrients and contaminants in aquatic systems. However, FeOx structure and reactivity is dependent on adsorption and incorporation of such dissolved species, particularly oxyanions such as phosphate and silicate. These interactions affect the fate of nutrients and metal(loids), especially in perturbed aquatic environments such as eutrophic coastal systems and environments impacted by acid mine drainage.
View Article and Find Full Text PDFIn this work, we combined macroscopic measurements of precipitate aggregation and chemical composition (Mn/Fe solids ratio) with Fe and Mn K-edge X-ray absorption spectroscopy to investigate the solids formed by co-oxidation of Fe(II) and Mn(II) with O, MnO, and HOCl in the presence of groundwater ions. In the absence of the strongly sorbing oxyanions, phosphate (P) and silicate (Si), and calcium (Ca), O and HOCl produced suspensions that aggregated rapidly, whereas co-oxidation of Fe(II) and Mn(II) by MnO generated colloidally stable suspensions. The aggregation of all suspensions decreased in P and Si solutions, but Ca counteracted these oxyanion effects.
View Article and Find Full Text PDFIron-electrocoagulation is a promising contaminant (e.g. arsenic) removal technology that is based on electrochemical Fe(II) production from steel electrodes and subsequent transport of Fe(II) to the bulk solution, where contaminant removal occurs.
View Article and Find Full Text PDFIn this study, concrete stabilization is adopted to sustainably manage hazardous arsenic-iron sludge near the vicinity of a community-based arsenic water treatment plant for potential use as material for local construction. The strength and workability of the sludge mixed with fresh concrete were investigated to determine the suitability of the concrete mixture for building materials. We found that over 25% sludge (with respect to cement weight) can be incorporated safely into different grades of concrete (M15 and M20).
View Article and Find Full Text PDFUrban stormwater, municipal wastewater effluent, and agricultural runoff contain trace amounts of organic contaminants that can compromise water quality. To provide a passive, low-cost means of oxidizing substituted phenols, aromatic amines, and other electron-rich organic compounds during infiltration of contaminated waters, we coated sand with manganese oxide using a new approach involving the room-temperature oxidation of Mn with permanganate. Manganese oxide-coated sand effectively oxidized bisphenol A under typical infiltration conditions and sustained reactivity longer than previously described geomedia.
View Article and Find Full Text PDFEnviron Sci Process Impacts
June 2018
Bacterial bioreporters are engineered microorganisms that have found recent application as a low-cost method of detecting arsenic (As) in environmental systems. However, no assessment exists of bioreporter detection of particle-bound As. We applied an Escherichia coli-based bioreporter to assess the bioavailability of As(v) adsorbed by goethite (α-FeOOH), 2-line ferrihydrite and As(v) co-precipitated with Fe(iii).
View Article and Find Full Text PDFEfficient and low-cost methods of removing aqueous Mn(II) are required to improve the quality of impacted groundwater supplies. In this work, we show that Fe(0) electrocoagulation (EC) permits the oxidative removal of Mn(II) from solution by reaction with the reactive oxidant species produced through Fe(II) oxidation. Manganese(II) removal was enhanced when the accumulation of aqueous Fe(II) was minimized, which was achieved at low Fe(II) production rates, high pH, the presence of HO instead of O as the initial Fe(II) oxidant, or a combination of all three.
View Article and Find Full Text PDFIron electrocoagulation (Fe-EC) is a low-cost process in which Fe(II) generated from an Fe(0) anode reacts with dissolved O2 to form (1) Fe(III) precipitates with an affinity for bacterial cell walls and (2) bactericidal reactive oxidants. Previous work suggests that Fe-EC is a promising treatment option for groundwater containing arsenic and bacterial contamination. However, the mechanisms of bacteria attenuation and the impact of major groundwater ions are not well understood.
View Article and Find Full Text PDFEnviron Sci Process Impacts
August 2016
Birnessite minerals (layer-type MnO2), which bear both internal (cation vacancies) and external (particle edges) metal sorption sites, are important sinks of contaminants in soils and sediments. Although the particle edges of birnessite minerals often dominate the total reactive surface area, especially in the case of nanoscale crystallites, the metal sorption reactivity of birnessite particle edges remains elusive. In this study, we investigated the sorption selectivity of birnessite particle edges by combining Cd(ii) and Pb(ii) adsorption isotherms at pH 5.
View Article and Find Full Text PDF