Introduction: Accurate platelet (PLT) counting is crucial for disease diagnosis and treatment, especially under the condition of thrombocytopenia and platelet transfusion. A few PLT counting approaches have been established including impedance and fluorescent methods. The impedance PLT counting (PLT-I) approach could be interfered by small non-PLT particles in the blood, such as RBC/WBC fragments, microcytes, bacteria, and cryoglobulins.
View Article and Find Full Text PDFTraditional "one for one channel" long-wavelength probes in hematology analyzers limit their resolution and detection efficiency. In this study, we developed a "one for two channels" probe named NATO, which shows a short wavelength (λ = 460 nm), good nucleus and nucleolus location, and a high signal-to-noise ratio to nucleic acids. When NATO was made into a hematology analysis kit and applied in an automated hematology analyzer, short-wavelength absorbance endows NATO with higher resolution, which in turn leads to better separation of red blood cells and platelets in the blood shadow of the differentiating (DIFF) channel.
View Article and Find Full Text PDFThe introduction of Lawesson's reagent into a bis-rhodamine spirolactam system afforded a new fluorescent sensor for Cu(2+) ions, SRR, which contained a new tridentate sulfur ligand. SRR showed excellent specificity for Cu(2+) ions over other cations (including Cu(+), Hg(2+), and Fe(3+)), very high sensitivity (10 nM), and a rapid response time (3 min). The detection mechanism was investigated by (1)H NMR, (13)C NMR, (31)P NMR, and ESR spectroscopy, MS, and Gaussian calculations.
View Article and Find Full Text PDFBorn to dye: Five fluorescein analogues were synthesised (see scheme). One analogue was found to emit in the NIR region with a high quantum yield, excellent photostability and good permeability. Three derivatives were found to specifically stain mitochondria and one dye responds to thiols with a strong turn-on NIR fluorescence signal and colorimetric change, in vitro and in vivo.
View Article and Find Full Text PDFChem Commun (Camb)
March 2012
A specific ratiometric nanoprobe for hypochlorite was constructed as a paradigm of FRET spectral unmixing. The separation of FRET pairs' emissions reaches 175 nm, which ensures that the FRET probing is more accurate. This new nanoprobe shows high selectivity and potential in biological systems.
View Article and Find Full Text PDFZhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi
February 2004
Objective: To provide scientific basis data for revising the national hygiene criteria of "Classification of hazard conditions of productive dust" (GB5817-86).
Methods: The data of the retrospective study and the field survey data were analyzed with correlation and regression analysis. The product of total dust concentration of respiratory exposure (mg/m(3)), total ventilation during exposure (m(3)/d per psrson), and level of free SiO(2) in dust (%) was the respiratory exposure dose of free SiO(2) (mg per day per person) which was used as dose criteria value of classification of hazard degree of dust.