Focal adhesions (FAs) strengthen their link with the actin cytoskeleton to resist force. Talin-vinculin association could reinforce actin anchoring to FAs by controlling actin polymerization. However, the actin polymerization activity of the talin-vinculin complex is not known because it requires the reconstitution of the mechanical and biochemical activation steps that control the association of talin and vinculin.
View Article and Find Full Text PDFIn preclinical research, in vivo imaging of mice and rats is more common than any other animal species, since their physiopathology is very well- known and many genetically altered disease models exist. Animal studies based on small rodents are usually performed using dedicated preclinical imaging systems with high spatial resolution. For studies that require animal models such as mini- pigs or New-Zealand White (NZW) rabbits, imaging systems with larger bore sizes are required.
View Article and Find Full Text PDFIEEE Trans Vis Comput Graph
November 2024
Previous research has shown that integrating haptic feedback can improve immersion and realism in automotive VR applications. However, current haptic feedback approaches primarily focus on a single feedback type. This means users must switch between devices to experience haptic stimuli for different feedback types, such as grabbing, collision, or weight simulation.
View Article and Find Full Text PDFIn movement analysis, correlated random walk (CRW) models often use so-called turning angles, which are measured relative to the previous movement direction. To segregate between different movement modes, hidden Markov models (HMMs) describe movements as piecewise stationary CRWs in which the distributions of turning angles and step sizes depend on the underlying state. This typically allows for the segregation of movement modes that show different movement speeds.
View Article and Find Full Text PDFBackground: Preclinical research and organ-dedicated applications use and require high (spatial-)resolution positron emission tomography (PET) detectors to visualize small structures (early) and understand biological processes at a finer level of detail. Researchers seeking to improve detector and image spatial resolution have explored various detector designs. Current commercial high-resolution systems often employ finely pixelated or monolithic scintillators, each with its limitations.
View Article and Find Full Text PDFSteroid hormone receptors are ligand-binding transcription factors essential for mammalian physiology. The androgen receptor (AR) binds androgens mediating gene expression for sexual, somatic and behavioural functions, and is involved in various conditions including androgen insensitivity syndrome and prostate cancer. Here we identified functional mutations in the formin and actin nucleator DAAM2 in patients with androgen insensitivity syndrome.
View Article and Find Full Text PDFEffective science communication is fundamental to closing the gap from research and innovation to clinical implementation. Existing paradigms of science communication are often challenged by a lack of skill and engagement, particularly from those who progress the science. Currently, a standardized curriculum on science communication, with global applicability, does not exist.
View Article and Find Full Text PDFBackground: The prevalence of mental disorders, particularly adjustment disorder (AD), major depressive disorder (MDD) and panic disorder (PD) is increased in patients with pulmonary arterial hypertension (PAH). However, it is unclear which pathogenic mechanisms determine their development and could therefore be targeted in prevention or therapeutic interventions. Here, we assessed metacognitions in a sample of PAH patients with and without MDD and PD.
View Article and Find Full Text PDFBackground: Mental disorders are common among patients with severe cardiovascular diseases (CVD). Yet, there is a lack of easily accessible evidence-based treatments. Recent research indicates elevated prevalence of dysfunctional metacognitions in patients with mental disorders following cardiovascular events.
View Article and Find Full Text PDFPlants respond to higher temperatures by the action of heat stress (HS) transcription factors (Hsfs), which control the onset, early response, and long-term acclimation to HS. Members of the HsfA1 subfamily, such as tomato HsfA1a, are the central regulators of HS response, and their activity is fine-tuned by other Hsfs. We identify tomato HsfA7 as capacitor of HsfA1a during the early HS response.
View Article and Find Full Text PDFHistone deacylase 11 and human sirtuins are able to remove fatty acid-derived acyl moieties from the ε-amino group of lysine residues. Specific substrates are needed for investigating the biological functions of these enzymes. Additionally, appropriate screening systems are required for identification of modulators of enzymatic activities of HDAC11 and sirtuins.
View Article and Find Full Text PDFThe power degradation and failure of photovoltaic (PV) modules can be caused by changes in the mechanical properties of the polymeric components during the module lifetime. This paper introduces instrumented nanoindentation as a method to investigate the mechanical properties of module materials such as polymeric encapsulants. To this end, nanoindentation tests were carried out on ethylene vinyl acetate (EVA) surfaces, which have been separated from the glass panel.
View Article and Find Full Text PDFBackground And Purpose: The restricted bore diameter of current simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI) systems can be an impediment to achieving similar patient positioning during PET/MRI planning and radiotherapy. Our goal was to evaluate the B transmit (B ) uniformity, B efficiency, and specific absorption rate (SAR) of a novel radiofrequency (RF) body coil design, in which RF shielded PET detectors were integrated with the specific aim of enabling a wide-bore PET/MRI system.
Materials And Methods: We designed and constructed a wide-bore PET/MRI RF body coil to be integrated with a clinical MRI system.
Wild relatives of crops thrive in habitats where environmental conditions can be restrictive for productivity and survival of cultivated species. The genetic basis of this variability, particularly for tolerance to high temperatures, is not well understood. We examined the capacity of wild and cultivated accessions to acclimate to rapid temperature elevations that cause heat stress (HS).
View Article and Find Full Text PDFThe Hyperion II PET insert is the first scanner using fully digital silicon photomultipliers for simultaneous PET/MR imaging of small animals up to rabbit size. In this work, we evaluate the PET performance based on the National Eletrical Manufacturers Association (NEMA) NU 4-2008 standard, whose standardized measurement protocols allow comparison of different small-animal PET scanners. The Hyperion II small-animal PET/MR insert comprises three rings of 20 detector stacks with pixelated scintillator arrays with a crystal pitch of 1 mm, read out with digital silicon photomultipliers.
View Article and Find Full Text PDFBackground: Optimal healing of the myocardium following myocardial infarction (MI) requires a suitable degree of inflammation and its timely resolution, together with a well-orchestrated deposition and degradation of extracellular matrix (ECM) proteins.
Methods And Results: MI and SHAM-operated animals were imaged at 3,7,14 and 21 days with 3T magnetic resonance imaging (MRI) using a F/H surface coil. Mice were injected with F-perfluorocarbon (PFC) nanoparticles to study inflammatory cell recruitment, and with a gadolinium-based elastin-binding contrast agent (Gd-ESMA) to evaluate elastin content.
J Phys Chem C Nanomater Interfaces
April 2018
Aerosols can act as cloud condensation nuclei and/or ice-nucleating particles (INPs), influencing cloud properties. In particular, INPs show a variety of different and complex mechanisms when interacting with water during the freezing process. To gain a fundamental understanding of the heterogeneous freezing mechanisms, studies with proxies for atmospheric INPs must be performed.
View Article and Find Full Text PDFPurpose: In order to integrate electronic devices into a magnetic resonance imaging (MRI) scanner, shielding of the electronics with respect to the radio frequency (RF) transmit and receive system of the MRI scanner is required. Furthermore, MRI uses time-varying low-frequency magnetic fields for spatial encoding, i.e.
View Article and Find Full Text PDFIn this work we synthesized well-ordered, TaO films with a 3D-interconnected gyroid mesopore architecture with large pore sizes beyond 30 nm and extended crystalline domains through self-assembly of tailor-made triblock-terpolymers. This has effectively eliminated diffusion limitations inherent to previously reported mesoporous photocatalysts and resulted in superior hydrogen evolution with apparent quantum yields of up to 4.6% in the absence of any cocatalyst.
View Article and Find Full Text PDFThe combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET-MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is challenging. As one of the major issues, both the PET detectors and the MRI radio-frequency (RF) subsystem are exposed to electromagnetic (EM) interference, which may lead to PET and MRI signal-to-noise ratio (SNR) deteriorations.
View Article and Find Full Text PDFHyperion-II(D) is a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. To read out the scintillation light of the employed lutetium yttrium orthosilicate crystal arrays with a pitch of 1 mm and 12 mm in height, digital silicon photomultipliers (DPC 3200-22, Philips Digital Photon Counting) (DPC) are used. The basic PET performance in terms of energy resolution, coincidence resolution time (CRT) and sensitivity as a function of the operating parameters, such as the operating temperature, the applied overvoltage, activity and configuration parameters of the DPCs, has been evaluated at system level.
View Article and Find Full Text PDFBiomed Phys Eng Express
February 2016
Advances in solid-state photon detectors paved the way to combine positron emission tomography (PET) and magnetic resonance imaging (MRI) into highly integrated, truly simultaneous, hybrid imaging systems. Based on the most recent digital SiPM technology, we developed an MRI-compatible PET detector stack, intended as a building block for next generation simultaneous PET/MRI systems. Our detector stack comprises an array of 8 × 8 digital SiPM channels with 4 mm pitch using Philips Digital Photon Counting DPC 3200-22 devices, an FPGA for data acquisition, a supply voltage control system and a cooling infrastructure.
View Article and Find Full Text PDF