Purpose: To compare the development of posterior capsule opacification (PCO) between eyes with and without posterior capsule plaque after single-piece hydrophobic acrylic intraocular lens (IOL) implantation 5 years postoperatively.

Design: A prospective observational case-control study.

Methods: One hundred one consecutive eyes with posterior capsule plaque (cases) were compared with the same number of cataractous eyes without posterior capsule plaque (controls).

View Article and Find Full Text PDF

Purpose: To evaluate the long-term effect of a single-piece hydrophobic acrylic intraocular lens (IOL), AcrySof SN60AT (Alcon Laboratories, Fort Worth, Texas, USA), on the development of posterior capsule opacification (PCO) 5 years postoperatively.

Design: Prospective, observational, consecutive, case series.

Methods: setting: Iladevi Cataract and IOL Research Center, Ahmedabad, India.

View Article and Find Full Text PDF

Purpose: To determine the incidence of intraoperative posterior capsule striae after implantation of a 1-piece hydrophobic acrylic intraocular lens (IOL), study the clinical impact on the patients' vision, and assess whether the presence of posterior capsule striae increases the risk for posterior capsule opacification (PCO).

Setting: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.

Design: Case-control study.

View Article and Find Full Text PDF

Purpose: To evaluate the rotational stability of a toric intraocular lens (IOL) using purpose-designed software and to determine the influence of axial length (AL) and in-the-bag IOL alignment on IOL rotation.

Setting: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.

Design: Prospective observational case series.

View Article and Find Full Text PDF

Purpose: To evaluate posterior capsule opacification (PCO) development after cataract surgery in eyes with or without a history of steroid use.

Setting: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.

Design: Comparative case series.

View Article and Find Full Text PDF

Purpose: To determine whether axial myopia affects posterior capsule opacification (PCO) in eyes with high myopia (axial length [AL] > or = 26.00 mm) 4 years after implantation of an AcrySof single-piece intraocular lens (IOL).

Setting: Clinical practice, Ahmedabad, India.

View Article and Find Full Text PDF

A specially designed grid and software used to assess the postoperative rotation of a toric intraocular lens (IOL) are described. Postoperatively, a digital retroillumination image of the patient is taken and this image is superimposed on the grid. The software determines the center of the IOL.