Publications by authors named "Garsse L"

Background: Patients with severe aortic stenosis present frequently (∼50%) with concomitant obstructive coronary artery disease. Current guidelines recommend combined surgical aortic valve replacement (SAVR) and coronary artery bypass grafting (CABG) as the preferred treatment. Transcatheter aortic valve implantation (TAVI) and fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) represent a valid treatment alternative.

View Article and Find Full Text PDF
Article Synopsis
  • - The study evaluated the safety and efficacy of using an upper-extremity approach for secondary access during transfemoral transcatheter aortic valve implantation (TAVI) compared to the traditional lower-extremity method, as it may reduce significant bleeding risks.
  • - Conducted between November 2022 and November 2023 in the Netherlands, the TAVI XS trial involved 238 patients with severe aortic stenosis, who were randomly assigned to either the upper or lower access groups.
  • - Results showed that the upper-extremity approach had a lower incidence of clinically relevant bleeding (4.2% vs. 13.4% for the lower extremity), suggesting it could be a safer option for patients undergoing
View Article and Find Full Text PDF

Mitral annular abscesses are rare and can be caused by infective endocarditis. We present the case of a patient with an infected mitral prosthesis, with multiple suspected periprosthetic abscesses. However, perioperative inspection showed a supra-annular implanted prosthesis.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is the standard of care in aortic stenosis with results comparable to surgical aortic valve replacement. However, paravalvular regurgitation (PVR) is more common after TAVR. With the alteration of devices and implantation techniques, the incidence of moderate or more PVR has declined.

View Article and Find Full Text PDF

Background: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking.

View Article and Find Full Text PDF

The femoral vein is commonly used as a pacemaker access site during transcatheter aortic valve replacement (TAVR). Using an upper arm vein as an alternative access site potentially causes fewer bleeding complications and shorter time to mobilization. We aimed to assess the safety and efficacy of an upper arm vein as a temporary pacemaker access site during TAVR.

View Article and Find Full Text PDF

Background: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD.

View Article and Find Full Text PDF
Article Synopsis
  • The study compares transaxillary (TAx) access and transfemoral (TF) access in transcatheter aortic valve implantation (TAVI) to assess their safety and efficacy.
  • A total of 6,334 patients were evaluated, with 322 from each group after reducing selection bias.
  • Results showed that both access methods had similar mortality rates at 30 days and one year, but TAx had a higher rate of myocardial infarction and a lower rate of permanent pacemaker implantations compared to TF access.
View Article and Find Full Text PDF

Background: endocarditis is a rare but fulminant disease.

Case Summary: A 74-year-old female with a history of asymptomatic severe aortic valve stenosis and permanent atrial fibrillation presented with acute onset of fever (39.0°C).

View Article and Find Full Text PDF

Aims: Paravalvular regurgitation (PVR) is a common complication after transcatheter aortic valve replacement (TAVR) that poses an increased risk of rehospitalization for heart failure and mortality. The aim of this study was to assess the accuracy of haemodynamic indices to predict relevant PVR.

Methods And Results: In this prospective single-centre clinical trial, four haemodynamic indices of PVR measured during TAVR were assessed for their correlation with gold standard cardiac magnetic resonance (CMR)-derived regurgitant fraction (CMR-RF) at 1 month follow-up: diastolic delta (DD), heart rate-adjusted diastolic delta (HR-DD), aortic regurgitation index (ARI), and aortic regurgitation index ratio (ARI ratio).

View Article and Find Full Text PDF

Minimally invasive mitral valve surgery is evolving rapidly since the early 1990's and is now increasingly adopted as the standard approach for mitral valve surgery. It has a long and challenging learning curve and there are many considerations regarding technique, planning and patient selection when starting a minimally invasive program. In the current review, we provide an overview of all considerations and the decision-making process during the learning curve.

View Article and Find Full Text PDF

Introduction: The coronavirus disease 2019 (COVID-19) pandemic has put tremendous pressure on healthcare systems. Most transcatheter aortic valve implantation (TAVI) centres have adopted different triage systems and procedural strategies to serve highest-risk patients first and to minimise the burden on hospital logistics and personnel. We therefore assessed the impact of the COVID-19 pandemic on patient selection, type of anaesthesia and outcomes after TAVI.

View Article and Find Full Text PDF
Article Synopsis
  • Grading paravalvular leak (PVL) during TAVI deployment is difficult, and using invasive hemodynamic measurements can help improve grading and predict outcomes.
  • The study examined 651 patients with severe aortic valve stenosis treated with self-expanding TAVI devices from 2008 to 2017, collecting various hemodynamic and echocardiographic data.
  • The ARI ratio was identified as the strongest predictor of 1-year mortality, highlighting the importance of hemodynamic measures in assessing the risks associated with PVL during TAVI procedures.
View Article and Find Full Text PDF

Background And Aim Of The Study: The coronavirus disease 2019 (COVID-19) pandemic has put an enormous strain on healthcare systems and intensive care unit (ICU) capacity, leading to suspension of most elective procedures, including transcatheter aortic valve replacement (TAVR). However, deferment of TAVR is associated with significant wait-time mortality in patients with severe aortic valve stenosis. Conversely, there is currently no data available regarding the safety and feasibility of a continued TAVR program during this unprecedented crisis.

View Article and Find Full Text PDF

Extracorporeal circulation is accompanied by changes in red blood cell morphology and structural integrity that affect cell function and survival, and thereby may contribute to the various side effects of heart-lung machine-assisted surgery. Our main objectives were to determine the effect of circulation of red blood cells in a stand-alone extracorporeal circuit on several parameters that are known to be affected by, as well as contribute to red blood cell aging. As a source of RBCs, we employed blood bank storage units of different ages.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on vascular complications following transaxillary TAVI, particularly the incidence and predictors of axillary artery complications.
  • A total of 200 patients were analyzed, revealing a complication rate of 18.5%, with female gender and older age identified as significant risk factors.
  • The study concluded that computed tomography angiography (CTA) is a valuable tool for assessing patient eligibility and that evaluating the vascular luminal area is more effective than just measuring diameter.
View Article and Find Full Text PDF

Background/objectives: Prospectively collected data on postoperative delirium (POD) after transcatheter aortic valve implantation (TAVI) are scarce. The aim of this study was to report the incidence and risk factors of delirium after TAVI under general anesthesia and to assess the association of POD with clinical outcome and short- and long-term survival.

Design: Prospective cohort study.

View Article and Find Full Text PDF

Background: The femoral artery is generally used as primary access for transcatheter aortic valve implantation. However, peripheral artery disease often precludes femoral access. The purpose of this study was to describe clinical outcome of transcatheter aortic valve implantation using the left axillary artery (LAA) as primary access site.

View Article and Find Full Text PDF

Bone cement leakage is a common complication after percutaneous kyphoplasty. In rare cases, leakage into the venous system occurs, which can be life-threatening, especially when it embolizes the heart. Here, we present a case of cement embolization of the right ventricle with tricuspid valve involvement.

View Article and Find Full Text PDF

Objectives: To determine the optimal imaging time point for transcatheter aortic valve implantation (TAVI) therapy planning by comprehensive evaluation of the aortic root.

Methods: Multidetector-row CT (MDCT) examination with retrospective ECG gating was retrospectively performed in 64 consecutive patients referred for pre-TAVI assessment. Eighteen different parameters of the aortic root were evaluated at 11 different time points in the cardiac cycle.

View Article and Find Full Text PDF

Objectives: The aim of the study was to investigate trends over time in the occurrence of left bundle branch block (LBBB) and permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) with the Medtronic CoreValve System (MCS) and Edwards SAPIEN Valve (ESV).

Background: TAVI-induced conduction abnormalities (TAVI-CAs) such as LBBB and the need for PPI are frequent postoperative complication. New techniques, procedural refinements, and increased awareness are focused on the reduction of these abnormalities.

View Article and Find Full Text PDF

Objectives: Recently, transcatheter aortic valve implantation has been introduced, but one of its complications is left bundle branch block (LBBB), a conduction disturbance that has been associated with increased mortality. We investigated the incidence and fate of both right bundle branch block (RBBB) and LBBB after aortic valve replacement (AVR) using a retrospective analysis. We also studied the predictive value of both disorders for all-cause mortality.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation (TAVI) is an alternative treatment option for patients with severe aortic valve stenosis who do not qualify for surgical aortic valve replacement (AVR). Besides its proven clinical benefits, one of the complications of TAVI is the creation of conduction abnormalities, like left bundle branch block (LBBB). New LBBB occurs between 7 and 65% of cases, numbers that differ considerably between devices.

View Article and Find Full Text PDF