Background And Objective: The Yorkshire Kidney Screening Trial (YKST) assessed the feasibility of adding abdominal noncontrast computed tomography (NCCT) to lung cancer screening to screen for kidney cancer and other abdominal pathology.
Methods: A prospective diagnostic study offered abdominal NCCT to 55-80-yr-old ever-smokers attending a UK randomised lung cancer screening trial (May 2021 to October 2022). The exclusion criteria were dementia, frailty, previous kidney/lung cancer, and computed tomography (CT) of the abdomen and thorax within previous 6 and 12 mo, respectively.
Objectives: The Yorkshire Kidney Screening Trial (YKST) is a feasibility study of adding non-contrast abdominal CT scanning to screen for kidney cancer and other abdominal malignancies to community-based CT screening for lung cancer within the Yorkshire Lung Screening Trial (YLST). This study explored the acceptability of the combined screening approach to participants and healthcare professionals (HCPs) involved in the trial.
Methods: We conducted semi-structured interviews with eight HCPs and 25 participants returning for the second round of scanning within YLST, 20 who had taken up the offer of the additional abdominal CT scan and five who had declined.
Objectives: To evaluate radiation doses for all low-dose CT scans performed during the first year of a lung screening trial.
Methods: For all lung screening scans that were performed using a CT protocol that delivered image quality meeting the RSNA QIBA criteria, radiation dose metrics, participant height, weight, gender, and age were recorded. Values of volume CT dose index (CTDIvol) and dose length product (DLP) were evaluated as a function of weight in order to assess the performance of the scan protocol across the participant cohort.
Introduction: Kidney cancer (renal cell cancer (RCC)) is the seventh most common cancer in the UK. As RCC is largely curable if detected at an early stage and most patients have no symptoms, there is international interest in evaluating a screening programme for RCC. The Yorkshire Kidney Screening Trial (YKST) will assess the feasibility of adding non-contrast abdominal CT scanning to screen for RCC and other abdominal pathology within the Yorkshire Lung Screening Trial (YLST), a randomised trial of community-based CT screening for lung cancer.
View Article and Find Full Text PDFObjectives: To develop a CT scanning protocol for lung cancer screening which achieved low radiation dose and a high level of objectively assessed image quality.
Methods: An anthropomorphic chest phantom and a commercially available lung screening image quality phantom were scanned on a series of scan protocols from a previous UK lung screening pilot and on an alternative protocol. The chest phantom scans were used to assess the CT dose metrics on community-based mobile CT scanners and comparisons were made with published recommended doses.
Purpose: We aimed to evaluate the effect on the radiation dose to the patient by reducing the tube current during the placement of the ablation needles (reduced dose group) compared with the patient doses delivered when scanning at the standard fully diagnostic level (full dose group) in computed tomography (CT)-guided percutaneous cryoablation.
Methods: We conducted a retrospective study of 103 patients undergoing cryoablation in a tertiary cancer center. Overall, 62 patients were scanned with standard exposure parameters (full dose group) set on a 64-slice multidetector CT scanner, while 41 patients were scanned on a reduced dose protocol.
This work aims to assess the efficacy of x-ray quality assurance tests undertaken on fluoroscopy units in the UK. Information was gathered on the results of image quality tests recommended by the reports of the Institute of Physics and Engineering in Medicine, and those additionally undertaken by medical physics departments. The assessment of efficacy considers the frequency with which a test result breaches the remedial level or other relevant threshold where applicable.
View Article and Find Full Text PDFObjective: The aims of this study were 3-fold: first, establish the level of radiation exposure experienced by the pediatric trauma patients; second, model the level of risk of developing fatal carcinogenesis; and third, test whether pattern of injury was predictive of the level of exposure.
Summary Background Data: There are certain conditions that cause children to be exposed to increased radiation, that is, scoliosis, where level of radiation exposure is known. The extent that children are exposed to radiation in the context of multiple traumas remains unclear.
This work aims to assess the efficacy of x-ray quality assurance tests undertaken on fluoroscopy units in the UK. Information was gathered on the results of dosimetry and safety tests recommended by the reports of the Institute of Physics and Engineering in Medicine, and those additionally undertaken by medical physics departments. The assessment of efficacy considers the frequency with which a test result breaches the remedial level or other relevant threshold where applicable.
View Article and Find Full Text PDFBackground: The utilization of medical imaging continues to rise, including routine use in major trauma centers. The aims of this study were to estimate the amount of radiation exposure from radiographic imaging and the associated fatal carcinogenesis risk among patients treated for polytrauma at 1 institution.
Methods: Included were patients who were admitted to our institution with an Injury Severity Score (ISS) of ≥16 during the period of January 2007 to December 2016.
This work aims to assess the efficacy of current x-ray quality assurance (QA) testing regimes on tube and generator systems for general radiographic usage in the UK. 1393 sets of QA results data from nine UK medical physics departments were collected and analysed. Test failure rates ranged from 0% to 39% and were used to assess the likelihood of the test finding a fault.
View Article and Find Full Text PDFObjectives: The aim of this study was to conduct a nationwide survey of computed tomography (CT) doses for a wide range of PET-CT and single photon emission computed tomography-computed tomography (SPECT-CT) imaging procedures, with the aim of generating proposed UK national diagnostic reference levels (NDRLs).
Methods: CT protocol and dosimetry data for three PET-CT and seven SPECT-CT examinations were gathered from centres across the UK. Data were divided according to CT purpose (attenuation correction, localization or diagnostic) and third quartile values of scanner average dose metrics were used to generate suggested NDRLs for a range of examination and CT purpose combinations.
J Appl Clin Med Phys
July 2016
The study purpose was to develop and validate a quality assurance test for CT automatic exposure control (AEC) systems based on a set of nested polymethylmethacrylate CTDI phantoms. The test phantom was created by offsetting the 16 cm head phantom within the 32 cm body annulus, thus creating a three part phantom. This was scanned at all acceptance, routine, and some nonroutine quality assurance visits over a period of 45 months, resulting in 115 separate AEC tests on scanners from four manufacturers.
View Article and Find Full Text PDFObjectives: To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer.
Materials And Methods: A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated.
Objectives: Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging.
Materials And Methods: An audit of 70 patients was performed for half-body CT scans taken on a GE Discovery 690, Philips Gemini TF and Siemens Biograph mCT (all 64-slice CT).
Background: The use of imaging that employs ionising radiation is increasing in the setting of paediatric cardiology. Children's high radiosensitivity and the lack of contemporary radiation data warrant a review of the radiation doses from the latest "state-of-the-art" angiography and computed tomography systems.
Objectives: In children aged less than 16 years with congenital cardiac disease, we aimed to report: recent trends in the use of diagnostic angiography and cardiac dual-source computed tomography; the characteristics, lesions, and imaging histories of patients undergoing these procedures; and the average radiation doses imparted by each modality.
Eur J Nucl Med Mol Imaging