Publications by authors named "Garcia-Reyes J"

Microcystins (MCs) are cyclic heptapeptides originating from various cyanobacteria in eutrophic aquatic environments. Their potential consequences on ecosystems and public health underscores the need to explore MCs' occurrence. In this study, liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) analysis and a suspect screening workflow supported by open-source tools were employed for the determination of MCs in freshwater and biota samples from a eutrophic dam in Uruguay.

View Article and Find Full Text PDF

Sterols and triterpenic alcohol analyses are one of the officially established parameters for assessing the authenticity of virgin olive oil (VOO). Most of the applications described for sterol analysis, including the official method, only allow the determination of the total sterol content but not its distribution in free or esterified form. This work proposes a two-dimensional liquid chromatography/high-resolution mass spectrometry (2D-LC-HRMS) method for the simultaneous analysis of triterpenic alcohols, free sterols and steryl esters.

View Article and Find Full Text PDF

The pollution of natural waters by contaminants of emerging concern (CECs) is one of the pressing problems due to their global distribution and potential negative effects on the environment and human health. In rural areas with lower population density and limited industrial development, less contamination is expected. However, the lack of wastewater treatment plants (WWTPs) or their poor removal efficiency can lead to significant input of pollutants.

View Article and Find Full Text PDF

Ambient Ionization Mass Spectrometry (AI-MS) techniques have revolutionized analytical chemistry by enabling rapid analysis of samples under atmospheric conditions with minimal to no preparation. In this study, the optimization of a cold atmospheric plasma for the analysis of food and pharmaceutical samples, liquid and solid, using a Heat-Assisted Dielectric Barrier Discharge Ionization (HA-DBDI) source is described. A significant enhancement in analyte signals was observed when a heating element was introduced into the design, potentially allowing for greater sensitivity.

View Article and Find Full Text PDF

Pesticides are considered one of the main sources of contamination of surface waters, especially in rural areas highly influenced by traditional agricultural practices. The objective of this work was to evaluate the impact caused by pesticides and their transformation products (TPs) related to olive groves in surface waters with strong agricultural pressure. 11 streams were monitored during four sampling campaigns over 2 years.

View Article and Find Full Text PDF

In this article, we have studied the potential of flexible microtube plasma (FμTP) as ionization source for the liquid chromatography high-resolution mass spectrometry detection of non-easily ionizable pesticides (viz. nonpolar and non-ionizable by acid/basic moieties). Phthalimide-related compounds such as dicofol, dinocap, o-phenylphenol, captan, captafol, folpet and their metabolites were studied.

View Article and Find Full Text PDF

Paper spray mass spectrometry (PS-MS) has evolved into a promising tool for monitoring reactions in thin films and microdroplets, known as reactive PS, alongside its established role in ambient and direct ionization. This study addresses the need for rapid, cost-effective methods to improve analyte identification in biofluids by leveraging reactive PS-MS in clinical chemistry environments. The technique has proven effective in derivatizing target analytes, altering hydrophobicity to enhance elution and ionization efficiency, and refining detection through thin-film reactions on paper, significantly expediting reaction rates by using amino acids (AAs) as model analytes.

View Article and Find Full Text PDF

The present study investigated the potential for solvent-assisted laser desorption coupled with flexible microtube plasma ionization mass spectrometry (SALD-FμTP-MS) as a rapid analytical technique for direct analysis of surface-deposited samples. Paper was used as the demonstrative substrate, and an infrared hand-held laser was employed for sample desorption, aiming to explore cost-effective sampling and analysis methods. SALD-FμTP-MS offers several advantages, particularly for biofluid analysis, including affordability, the ability to analyze low sample volumes (<10 μL), expanded chemical coverage, sample and substrate stability, and in situ analysis and high throughput potential.

View Article and Find Full Text PDF

A new method for a fast molecular profiling of olive oil unsaponifiable fraction has been developed. This approach, based on paper spray mass spectrometry, allows obtaining MS data with only a few minutes of analysis and without significant solvent and disposable consumption. Tandem mass spectrometry and high-resolution mass spectrometry experiments have been performed to identify the main ions detected.

View Article and Find Full Text PDF

Liquid chromatography-mass spectrometry (LC-MS) is currently the gold-standard technique for the analysis of non-volatile small organic molecules. However, one-dimensional liquid chromatography (1D-LC) cannot efficiently deal with mixtures of analytes with different physicochemical properties and, thus, specific chromatographic behaviour. As an alternative, this work proposes a two-dimensional liquid chromatography/high-resolution mass spectrometry (2D-LC-HRMS) approach for the simultaneous analysis of compounds with different polarities.

View Article and Find Full Text PDF

Dielectric barrier discharges (DBD) are highly versatile plasma sources for forming ions at atmospheric pressure and near ambient temperatures for the rapid, direct, and sensitive analysis of molecules by mass spectrometry (MS). Ambient ion sources should ideally form intact ions, as in-source fragmentation can limit sensitivity, increase spectral complexity, and hinder interpretation. Here, we report the measurement of ion internal energy distributions for the four primary classes of DBD-based ion sources, specifically DBD ionization (DBDI), low-temperature plasma (LTP), flexible microtube plasma (FμTP), and active capillary plasma ionization (ACaPI), in addition to atmospheric pressure chemical ionization (APCI) using para-substituted benzylammonium thermometer ions.

View Article and Find Full Text PDF

In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analyzed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimization of the different analytical aspects that will condition the 2D-LC-MS performance.

View Article and Find Full Text PDF

In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analysed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimisation of the different analytical aspects that will condition the 2D-LC-MS performance.

View Article and Find Full Text PDF

Dielectric barrier discharge ionization (DBDI) is a versatile tool for small-molecule mass spectrometry applications, helping cover from polar to low polar molecules. However, the plasma gas-phase interactions are highly complex and have been scarcely investigated. The ionization mechanisms of plasmas have long been assumed to be somewhat similar to atmospheric pressure chemical ionization (APCI).

View Article and Find Full Text PDF

Dielectric barrier discharge ionization has gained attention in the last few years due to its versatility and the vast array of molecules that can be ionized. In this study, we report on the assessment of liquid chromatography coupled to dielectric barrier discharge ionization with mass spectrometry for neutral lipid analysis. A set of different neutral lipid subclasses (triacylglycerides, diacylglycerides, and sterols) were selected for the study.

View Article and Find Full Text PDF

Although electron impact ionization (EI) remains the standard ionization source for GC-MS, it presents extensive fragmentation as its main limitation. The potential of a novel plasma-based soft ionization source named controlled-atmosphere flexible microtube plasma (CA-FμTP) has been evaluated in this work for the determination of monoaromatic volatile BTEX group (namely benzene, toluene, ethylbenzene, and o-, m- and p-xylenes) in olive oil, based on headspace technique. The obtained results show an attractive advantage over EI due to no fragmentation was observed.

View Article and Find Full Text PDF

After more than ten years since pesticide residues were detected in citrus-flavored soft drinks, this study reveals that the situation has not changed. A new sensitive multiresidue UHPLC-MS/MS method has been validated for 88 pesticides, which was used to analyze 200 samples manufactured in 67 countries, 80% corresponding to fruit-based soft drinks. The results show that 98% of the samples collected worldwide contained at least one pesticide, and 85% of them contained more than 4 pesticides.

View Article and Find Full Text PDF

Datura species are well known because of their high concentration of tropane alkaloids, which has led to poisoning episodes when Datura is accidentally mixed with edible crops. Therefore, the European Union has set a maximum level in cereal-based infant food products of 1 µg kg for atropine and scopolamine. However, the occurrence of these compounds in other commodities has become a global concern.

View Article and Find Full Text PDF

Ambient mass spectrometry refers to the family of techniques that allows ions to be generated from condensed phase samples under ambient conditions and then, collected and analysed by mass spectrometry. One of their key advantages relies on their ability to allow the analysis of samples with minimal to no sample workup. This feature maps well to the requirements of food safety testing, in particular, those related to the fast determination of pesticide residues in foods.

View Article and Find Full Text PDF

The presence of pesticide residues in bees is of great interest, given the central role of bees as indicators for environmental assessment. The goal of this article is to propose a method to capture enhanced chemical information for these central environmental indicators. Most of the methods rely on the analysis of pooled samples rather than individual specimens due to practical sample preparation method considerations and limitations in sensitivity.

View Article and Find Full Text PDF
Article Synopsis
  • Emerging contaminants (ECs) like pharmaceuticals and banned pesticides are increasingly found in the environment, raising ecotoxicological concerns, particularly in two Atlantic coastal lagoons in Uruguay.
  • A comprehensive screening identified 56 compounds, including five banned pesticides, with high detection rates of pharmaceuticals and drugs near urban areas and elevated pesticide levels in agricultural zones.
  • Environmental risk assessments highlighted hormones as particularly harmful to aquatic life, marking this as the first extensive study on ECs in surface waters of Uruguay.
View Article and Find Full Text PDF

In this work, the multiclass detection of explosives and related compounds has been studied by liquid chromatography-high-resolution mass spectrometry by means of a time-of-flight mass spectrometer (TOFMS) operated in the negative ion mode, using dielectric barrier discharge ionization (DBDI). Reversed-phase high-performance liquid chromatography (HPLC) separation was performed using water-methanol mobile phase without any modifier, although the effect of ammonium acetate was studied. DBD plasma was generated by applying a square wave voltage of 2.

View Article and Find Full Text PDF

Plasma sources in atmospheric pressure soft-ionization mass spectrometry have gained significant interest in recent years. As many of these sources are used under ambient air conditions, their interaction with the surrounding atmosphere plays an important role in the ionization pathway. This study focuses on the interaction between the plasma source and the surrounding atmosphere by connecting the plasma source to the mass spectrometer using a 2 mm ID closed reactant capillary supplied by a reactant gas up to 500 mL per minute to gain a controlled atmosphere.

View Article and Find Full Text PDF

A nanoflow liquid chromatography high resolution mass spectrometry method for the quantification of mycotoxins in nuts has been developed. Two strategies based on QuEChERS methodology were evaluated. Thus, EMR-lipid was compared with a conventional mixture of PSA and C18 dispersive solid phase extraction sorbents which have been commonly used in this type of matrices as sample clean-up.

View Article and Find Full Text PDF

The spread of Datura sp. in European countries influences crop management and implies continuous food safety issues because of tropane alkaloids, atropine and scopolamine, the most relevant natural toxic compounds of this weed. These alkaloids can contaminate cereals to such a level that hampers food/feed related use and diverts batches of contaminated raw materials towards ultimate disposal such as burning.

View Article and Find Full Text PDF